PRTG Manual: SIMATIC S7-1200/1500 Alarm Status Sensor
The SIMATIC S7-1200/1500 Alarm Status sensor monitors the alarms of Siemens S7-1200/1500 PLCs via the S7 Web API.
The sensor message displays the alarm text of the most urgent active alarm. The sensor prioritizes an alarm that is still incoming and not yet acknowledged. If no such alarm exists, the sensor message shows the alarm with the most recent timestamp.
This sensor is in beta status. The operating methods and the available settings are still subject to change. Do not expect that all functions work properly, or that this sensor works as expected at all.
For a detailed list and descriptions of the channels that this sensor can show, see section Channel List.
- Dutch: SIMATIC S7-1200/1500 Alarm Status
- French: SIMATIC S7-1200/1500 Alarm Status
- German: SIMATIC S7-1200/1500 Alarm Status
- Japanese: SIMATIC S7-1200/1500 Alarm Status
- Portuguese: SIMATIC S7-1200/1500 Alarm Status
- Russian: SIMATIC S7-1200/1500 Alarm Status
- Simplified Chinese: SIMATIC S7-1200/1500 Alarm Status
- Spanish: SIMATIC S7-1200/1500 Alarm Status
Consider the following remarks and requirements for this sensor:
Remark |
Description |
|---|---|
Enabled Beta Sensors experimental feature |
This sensor requires that the Beta Sensors experimental feature is enabled.
|
S7 Web API |
This sensor requires S7 Web API to be enabled on the device. |
PLC firmware |
This sensor requires as of PLC firmware 3.1 on S7-1500 Standard, T, F, and V CPUs, as of PLC firmware 4.1 on S7-1500 R/H CPUs, and as of PLC firmware 1.0 on S7-1200 G2 CPUs. |
Credentials |
This sensor requires credentials for the S7 Web API in settings that are higher in the object hierarchy. The user account must have read_diagnostics permissions. |
IPv6 |
This sensor supports IPv6. |
Performance impact |
This sensor has a very low performance impact. |
Scanning interval |
This sensor has a fixed minimum scanning interval for performance reasons. You cannot use a shorter scanning interval. Consequently, shorter scanning intervals in the Monitoring settings are not available for this sensor.
|
Lookups |
This sensor uses lookups to determine the status values of one or more channels. |
Limits |
This sensor has predefined limits for one or several metrics. |
The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:
- plc
- s7
- s7web
- s7webalarmstatussensor
- siemens
For more information about basic sensor settings, see section Sensor Settings.
Setting |
Description |
|---|---|
Primary Channel |
Select a channel from the list to define it as the primary channel. In the device tree, PRTG displays the last value of the primary channel below the sensor's name. The available options depend on what channels are available for this sensor.
|
Graph Type |
Define how this sensor shows different channels:
|
Stack Unit |
This setting is only visible if you select Stack channels on top of each other above. Select a unit from the list. PRTG stacks all channels with this unit on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so. |
Setting |
Description |
|---|---|
Result Handling |
Define what PRTG does with the sensor result:
|
By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click
under the corresponding setting name to disable the inheritance and to display its options.
For more information, see section Inheritance of Settings.
Which channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.
Channel |
Description |
|---|---|
[Module Name] Alarm Status |
This channel is only available as of PLC firmware 4.1 and does not appear on redundant S7-1500 R/H systems. The alarm status of a hardware module or the CPU, based on the system diagnostic alarms for this module
Channel names correspond to the module names configured in the TIA Portal. The alarms of the CPU module also count toward the System Diagnostic Alarms channel. To monitor the operating state of the CPU, use the SIMATIC S7-1200/1500 CPU Status sensor. |
Downtime |
In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status. |
Other Alarms |
The number of active alarms that do not fall into the program alarms or system diagnostic alarms category, for example motion, security, sinumerik, graph7, or prodiag alarms |
Program Alarms |
The number of active program alarms |
System Diagnostic Alarms |
The number of active system diagnostic alarms This channel counts the alarms of the CPU module as well. |
Total Alarms |
The total number of active alarms, regardless of category or acknowledgment status |
Total Unacknowledged Alarms |
The number of active alarms that are not yet acknowledged Alarms without an acknowledgment object cannot be acknowledged. This channel excludes them.
|