PRTG Manual: FTP Server File Count v2 Sensor
The FTP Server File Count v2 sensor monitors the number of files on a File Transfer Protocol (FTP) server.
For a detailed list and descriptions of the channels that this sensor can show, see section Channel List.
- Dutch: FTP Server File Count v2
- French: FTP Server File Count v2
- German: FTP Server File Count v2
- Japanese: FTP Server File Count v2
- Portuguese: FTP Server File Count v2
- Russian: FTP Server File Count v2
- Simplified Chinese: FTP Server File Count v2
- Spanish: FTP Server File Count v2
Consider the following remarks and requirements for this sensor:
Remark |
Description |
|---|---|
Credentials |
This sensor requires credentials for FTP in settings that are higher in the object hierarchy. |
IPv6 |
This sensor supports IPv6. |
Performance impact |
This sensor has a very low performance impact. |
The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:
- file
- filecount
- ftp
- ftpcount
For more information about basic sensor settings, see section Sensor Settings.
Setting |
Description |
|---|---|
FTP URL |
Enter the URL of the folder that you want to monitor. The default value is ftp://%host/. You can use the placeholder %host for the IP address or hostname of the parent device. For example, ftp://192.0.2.0/path/to/folder/.
|
Recurse Subfolders |
Specify if the sensor includes subfolders in the folder monitoring:
|
FTP Mode |
Select the connection mode for the data transfer:
|
Request Timeout (Sec.) |
Enter a timeout in seconds for the request. Enter an integer. The maximum timeout value is 900 seconds (15 minutes). The default value is 30 seconds. The minimum value is 5 seconds.
|
Encryption Mode |
Select the encryption mode for the connection:
|
Setting |
Description |
|---|---|
Primary Channel |
Select a channel from the list to define it as the primary channel. In the device tree, PRTG displays the last value of the primary channel below the sensor's name. The available options depend on what channels are available for this sensor.
|
Graph Type |
Define how this sensor shows different channels:
|
Stack Unit |
This setting is only visible if you select Stack channels on top of each other above. Select a unit from the list. PRTG stacks all channels with this unit on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so. |
Setting |
Description |
|---|---|
Result Handling |
Define what PRTG does with the sensor result:
|
By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click
under the corresponding setting name to disable the inheritance and to display its options.
For more information, see section Inheritance of Settings.
Which channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.
Channel |
Description |
|---|---|
Downtime |
In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status. |
Execution Time |
The execution time |
Files Since Last Scan |
The number of new files that PRTG found since the last scan |
Total Files |
The number of files that PRTG found during the last scan
|