PRTG Manual: LDAP Sensor
The LDAP sensor monitors directory services using the Lightweight Directory Access Protocol (LDAP). It connects to the server by trying a "bind". If the server does not respond or authentication fails, the sensor shows the Down status.
The sensor can show the following:
- Response time of the server
- Dutch: LDAP
- French: LDAP
- German: LDAP
- Japanese: LDAP
- Portuguese: LDAP
- Russian: LDAP
- Simplified Chinese: LDAP
- Spanish: LDAP
- This sensor officially supports Microsoft implementations of LDAP. Other third-party LDAP implementations might work but are not officially supported.
- This sensor requires a DNS name in the settings of the parent device if you use a Secure Sockets Layer (SSL)/Transport Layer Security (TLS) secured connection to the LDAP server.
- This sensor has a medium performance impact.
The Add Sensor dialog appears when you manually add a new sensor to a device. It only shows the setting fields that are required for creating the sensor. Therefore, you do not see all setting fields in this dialog. You can change (nearly) all settings in the sensor's Settings tab later.
Click the Settings tab of a sensor to change its settings.
Usually, a sensor connects to the IP Address or DNS Name of the parent device on which you created the sensor. See the device settings for details. For some sensors, you can explicitly define the monitoring target in the sensor settings. See below for details on available settings.
Setting |
Description |
---|---|
Sensor Name |
Enter a meaningful name to identify the sensor. By default, PRTG shows this name in the device tree, as well as in alarms, logs, notifications, reports, maps, libraries, and tickets.
|
Parent Tags |
Shows tags that the sensor inherits from its parent device, parent group, and parent probe. This setting is shown for your information only and cannot be changed here. |
Tags |
Enter one or more tags. Confirm each tag with the Spacebar key, a comma, or the Enter key. You can use tags to group objects and use tag-filtered views later on. Tags are not case-sensitive. Tags are automatically inherited.
The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:
|
Priority |
Select a priority for the sensor. This setting determines the position of the sensor in lists. The highest priority is at the top of a list. Choose from the lowest priority ( |
Setting |
Description |
---|---|
Connection Security |
Define if the sensor uses an SSL/TLS-secured connection to the LDAP server:
|
Port Selection |
Define if you want to use a default port or a custom port for the connection to the LDAP server:
|
Port |
This setting is only visible if you enable Use custom port. Enter a custom port for the connection to the LDAP server. Enter an integer value. |
Distinguished Name |
Enter the distinguished name (DN) that you want to authenticate against the LDAP server. Usually, this is the information for the user that you want to authenticate with. For example, use the format cn=Manager,dc=my-domain,dc=com for a DN on an OpenLDAP server. |
Password |
Enter the password for the entered Distinguished Name. |
Setting |
Description |
---|---|
Primary Channel |
Select a channel from the list to define it as the primary channel. In the device tree, the last value of the primary channel is always displayed below the sensor's name. The available options depend on what channels are available for this sensor.
|
Graph Type |
Define how different channels are shown for this sensor:
|
Stack Unit |
This setting is only visible if you enable Stack channels on top of each other as Graph Type. Select a unit from the list. All channels with this unit are stacked on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so. |
By default, all of the following settings are inherited from objects that are higher in the hierarchy. You should change them centrally in the root group settings if necessary. To change a setting for this object only, click under the corresponding setting name to disable the inheritance. You then see the options described below.
For more information, see section Inheritance of Settings.
Click to interrupt the inheritance.
Setting |
Description |
---|---|
Scanning Interval |
Select a scanning interval from the dropdown list. The scanning interval determines the amount of time that the sensor waits between two scans. Choose from:
|
If a Sensor Query Fails |
Select the number of scanning intervals that the sensor has time to reach and to check a device again if a sensor query fails. Depending on the option that you select, the sensor can try to reach and to check a device again several times before the sensor shows the Down status. This can avoid false alarms if the monitored device only has temporary issues. For previous scanning intervals with failed requests, the sensor shows the Warning status. Choose from:
|
Schedules, Dependencies, and Maintenance Window
You cannot interrupt the inheritance for schedules, dependencies, and maintenance windows. The corresponding settings from the parent objects are always active. However, you can define additional schedules, dependencies, and maintenance windows. They are active at the same time as the parent objects' settings.
Setting |
Description |
---|---|
Schedule |
Select a schedule from the list. You can use schedules to monitor during a certain time span (days or hours) every week. Choose from:
|
Maintenance Window |
Select if you want to set up a one-time maintenance window. During a maintenance window, monitoring stops for the selected object and all child objects. They show the Paused status instead. Choose between:
|
Maintenance Begins |
This setting is only visible if you enable Set up a one-time maintenance window above. Use the date time picker to enter the start date and time of the one-time maintenance window. |
Maintenance Ends |
This setting is only visible if you enable Set up a one-time maintenance window above. Use the date time picker to enter the end date and time of the one-time maintenance window. |
Dependency Type |
Select a dependency type. You can use dependencies to pause monitoring for an object depending on the status of a different object. You can choose from:
|
Dependency |
This setting is only visible if you enable Select a sensor above. Click |
Dependency Delay (Sec.) |
This setting is only visible if you enable Select a sensor above. Define a time span in seconds for the dependency delay. After the master sensor for this dependency returns to the Up status, PRTG additionally delays the monitoring of the dependent objects by the time span you define. This can prevent false alarms, for example, after a server restart or to give systems more time for all services to start. Enter an integer value.
|
Click to interrupt the inheritance.
Setting |
Description |
---|---|
User Group Access |
Define the user groups that have access to the sensor. You see a table with user groups and group access rights. The table contains all user groups in your setup. For each user group, you can choose from the following group access rights:
|
For more information about sensor settings, see the following sections: