PRTG Manual: SIMATIC S7-300/400 CPU Restart Overview Sensor
The SIMATIC S7-300/400 CPU Restart Overview sensor monitors the CPU restart events of a Siemens S7-300 or S7-400 Programmable Logic Controller (PLC) via the S7 protocol.
This sensor is in beta status. The operating methods and the available settings are still subject to change. Do not expect that all functions work properly, or that this sensor works as expected at all.
For a detailed list and descriptions of the channels that this sensor can show, see section Channel List.
- Dutch: SIMATIC S7-300/400 CPU Restart Overview
- French: SIMATIC S7-300/400 CPU Restart Overview
- German: SIMATIC S7-300/400 CPU Restart Overview
- Japanese: SIMATIC S7-300/400 CPU Restart Overview
- Portuguese: SIMATIC S7-300/400 CPU Restart Overview
- Russian: SIMATIC S7-300/400 CPU Restart Overview
- Simplified Chinese: SIMATIC S7-300/400 CPU Restart Overview
- Spanish: SIMATIC S7-300/400 CPU Restart Overview
Consider the following remarks and requirements for this sensor:
Requirement |
Description |
|---|---|
This sensor requires that the Beta Sensors experimental feature is enabled.
|
|
Credentials |
This sensor requires connection settings for Siemens S7 in settings that are higher in the object hierarchy. |
Parent device |
This sensor requires that the parent device is a Siemens S7-300 or S7-400 programmable logic controller. |
IPv4 |
This sensor only supports IPv4. |
Performance impact |
This sensor has a very low performance impact. |
Lookups |
This sensor uses lookups to determine the status values of one or more channels. |
Scanning interval |
The minimum scanning interval of this sensor is 30 seconds. |
The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:
- plc
- s7
- s7restartoverviewsensor
- siemens
For more information about basic sensor settings, see section Sensor Settings.
Setting |
Description |
|---|---|
Primary Channel |
Select a channel from the list to define it as the primary channel. In the device tree, PRTG displays the last value of the primary channel below the sensor's name. The available options depend on what channels are available for this sensor.
|
Graph Type |
Define how this sensor shows different channels:
|
Stack Unit |
This setting is only visible if you select Stack channels on top of each other above. Select a unit from the list. PRTG stacks all channels with this unit on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so. |
Setting |
Description |
|---|---|
Result Handling |
Define what PRTG does with the sensor result:
|
By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click
under the corresponding setting name to disable the inheritance and to display its options.
For more information, see section Inheritance of Settings.
Which channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.
Channel |
Description |
|---|---|
Automatic Cold Restarts |
The number of automatic cold restarts |
Automatic Hot Restarts |
The number of automatic hot restarts |
Automatic Warm Restarts |
The number of automatic warm restarts |
Downtime |
In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status. |
Manual Cold Restarts |
The number of manual cold restarts |
Manual Hot Restarts |
The number of manual hot restarts |
Manual Warm Restarts |
The number of manual warm restarts |
Restart Event |
The restart event status
|
Total Restarts |
The total number of restarts since the first sensor scan |
KNOWLEDGE BASE
What are beta sensors and how can I use them?
What security features does PRTG include?