With this PRTG version we introduce the new SNMP Custom String v2 sensor that monitors a string returned by a specific object identifier (OID) via the SNMP. The sensor interprets the SNMP value returned by the OID as a string, a MAC address, or an IPv4 address and shows the interpreted value in the sensor message. We introduced this sensor as experimental BETA sensor with PRTG version 26.1.116.1498.
We added the new SNMP Printer v2 sensor to monitor printer status, consumables, and operational metrics via SNMP. The sensor supports IPv4 and IPv6. Depending on the monitored printer, the sensor creates the channels Total Pages Printed, Cover Status, Tray Status and Supply Status. The sensor message displays the printer console output. If no printers are defined in the device table, the sensor will report an error. This sensor introduces 1-based numbering for printer units, as well as removing ranged lookups in favor of direct percentage and lookup values.
With this PRTG version we introduce the new SNMP RMON v2 sensor that was rewritten to work also on the Multi-Platform Probe. The SNMP RMON v2 sensor monitors traffic on a device using the Remote Monitoring (RMON) standard via SNMP. In the Specific Sensor Settings you have the option to edit the settings Description or 64-bit on request. This information is collected during sensor creation and if 64-bit counters are enabled in the compatibility settings.
With this PRTG version we introduce the PRTG Installation Report, a new built-in report available by default in all standard PRTG installations under Reports menu. With this report you can collect data about your PRTG installation, including license information, system health and optimization recommendations. The report can be generated on-demand or scheduled for automated delivery. The report supports PDF, CSV and HTML formats.
For more information, please refer to the following Knowledge Base article: Vulnerabilities in PRTG prior v26.2.120.1449 | Paessler Knowledge Base
The Microsoft 365 Mailbox sensor now supports the setting Validate Latest Email, like for example, the IMAP sensor. The sensor will use the latest email from the filtered messages. If no filters are configured, all messages are taken into account. You can configure warning or error states based on the Subject, From or Body settings. Additionally, you can set the sensor to Down or Warning status based on age for the latest email.
Various other minor fixes and improvements, updated user manual.
In case of a manual update to this PRTG version and if you have previously activated the PRTG Database, you will see an installation window with the message that the installation has stopped in order to keep your existing data. This is due to a new schema update in this PRTG version. The installation window will provide further instructions on how to proceed with the update.
The auto-update process will currently stop when you update to this PRTG version if you have previously activated the PRTG Database and have existing data. This issue affects you if you have set your auto-update to Automatically download and install in the Software Auto-Update settings. PRTG will create a TO DO ticket Error: The update cannot continue due to a change in the database schema if you run into this issue. For more information, please see our Knowledge Base article: https://helpdesk.paessler.com/en/support/solutions/articles/76000088264
We updated the list and location of the example scripts for custom sensors in the PRTG program directory. This removes all Demo scripts from the pre populated custom scripts directory. Scripts that were not deemed as risky are preserved under the examples script directory. Additionally, we have updated the example scripts for Script v2 to follow a more modern structure. Please note that in course of this change that we removed any .dll and .exe demo binary from PRTG.
To be consistent with our changes in PRTG version 26.1.118.1380 to display information about sensor usage and licensing in the New UI, we removed the Number of Sensors part under License Information on the PRTG System Status page.
We fixed an issue where in certain cases an enabled Geo Map could lead to ajax timeout errors or slow performance in the PRTG web interface. You could observe this issue when your PRTG core server was blocked in your firewall for outgoing connections and PRTG would try to reach the geolocation service continuously. A possible workaround was to disable Geo maps.
We fixed an issue where in certain cases an enabled Geo Map could lead to ajax timeout errors or slow performance in the PRTG web interface. You could observe this issue when your PRTG core server was blocked in your firewall for outgoing connections and PRTG would try to reach the geolocation service continuously. A possible workaround was to disable Geo maps.
We fixed an issue where the PRTG core service used a large amount of memory in rare cases which caused the system to run out of memory in the end. You could find the error message out of memory in the core log file in such cases.
We fixed an issue for the NetApp SnapMirror v2 sensor which regularly went into an error state and did not return any values for certain channels. The ONTAP API omitted transfer fields for continuously synced relationships and the sensor would handle the missing values as error. The issue happened when you used ONTAP with SnapMirror Active Sync and Consistency Groups.
We have improved the DNS v2 sensor regarding filtering reliability and result consistency. Null MX records are now correctly displayed as 0 if a domain does not accept emails, and DNS records of the same type are now sorted alphanumerically to ensure consistent output across repeated requests. Record values are trimmed before filter matching to prevent whitespace-related mismatches. A new Match the full result exactly filter mode has been added for record types whose values naturally contain commas, such as TXT and NAPTR. The internal connectivity check now queries the root domain for NS records instead of using a localhost ANY query, improving compatibility with modern DNS servers.
We fixed an issue where Run Auto-discovery with Templates led to an error (bad request) when you selected device templates via multi edit. Previously, it was only possible to select device templates on the first page of the pop-up window. As soon as you selected a device template on the second page or beyond, an error message appeared stating no device template had been selected.
We fixed an issue for Desktop Client and MultiBoard related API keys that you can create in PRTG via Add API Key for PRTG MultiBoard button. The issue happened when you started the Single Sign-on login flow calling getdesktoptoken.htm. The API key that was returned from the endpoint did not work for Single Sign-on content in those cases.
We currently face an issue where it is not possible to log in via Single Sign-on after enabling PRTG Database for data migration. If you have set up Single Sign-on before and migrated your configuration to PRTG database, the login with Single Sign-on would fail afterwards. In the User Group Settings you could observe that the SSO Group Claim was missing. A possible workaround is to set up a new Single Sign-on user group.
Please note that with updating to this PRTG version, the auto-update process takes longer because it includes the PRTG database and related components, which increase the size of the PRTG installer. We strongly recommend that you do not restart PRTG during this process and wait until the update is complete.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Stable 26.2.120.1449
We fixed an issue where sensor tags were lost after migrating configuration and monitoring data to the PRTG database. This caused sensors to become invisible in tag-based filters, making libraries and reports that rely on tag filtering no longer work as expected. This issue applied to the WMI Free Disk Space (Multi Disk) sensor, for example.
We improved the retry mechanism for the SIMATIC S7-300/400 CPU Restart Overview sensor to reduce false alerts caused by intermittent errors when querying data from a PLC via S7. Previously, the PLC would occasionally return a CPU : Item not available error, causing the sensor to go into a down state for one or more scans before recovering, despite the PLC working correctly the whole time. When the PLC is too busy to serve the request of the sensor, the request is now retried after a delay of 100 ms, with a configurable maximum delay of up to 1000 ms.
We fixed an issue for the SNMP Traffic v2 sensor that wrongly displayed 4 GBit/s as a result for unconnected ports in certain cases. The issue happened mostly for SNMP version v1 or high speed interface connections. The sensor will now display the status Unknown correctly for non-available entries instead of a wrong value.
We fixed an issue where the Channel Unit Configuration did not display the correct units for Disk size, File size and Memory size.
We fixed an issue for the object tree under Monitoring where object calculation did not work properly for groups that contained only empty objects (groups or devices) and no sensors.
You are now able to use the following Device Action buttons via context menu: Reorder Tree, Copy and Paste. After you have copied an object, a success message appears. The same applies to the object once you have successfully pasted it. If you do not have the necessary access rights to an object, the buttons in the context menu will appear disabled and display the text no permission.
We fixed an issue where in certain cases an unknown error occurred with the message Something went wrong. Please refresh your browser or try again later. The issue in the new UI happened sporadically and in cases when you closed the browser and opened PRTG again with a page using iframes.
Prtg 26.1.118 is Now Available in the Stable Release Channel
We just released PRTG version 26.1.118 to the stable release channel - and this one is packed. The highlight of this release is the first Beta of PRTG Database, a brand-new PostgreSQL-based storage layer designed to boost efficiency and speed in large PRTG installations. On top of that, you get two new experimental sensors for Proxmox VE, the new SNMP Windows Service v2 sensor, a rewritten...
Read the complete blog post hereWith this PRTG version we introduce the new SNMP Windows Service v2 sensor that was rewritten to provide improved reliability and maintainability. This sensor monitors a Windows service via SNMP and uses credentials in Credentials for SNMP Devices that you have to configure in the device settings.
We improved the authentication implementation of PRTG to defend against potential timing attacks and username enumeration. CVE is still pending.
For more information, please refer to the following Knowledge Base article: Vulnerabilities in PRTG prior v26.2.120.1449 | Paessler Knowledge Base
With this PRTG version we support authNoPriv as Authentication Method for SNMP sensors and SNMP version v3. The authNoPriv mode enables you to monitor infrastructures that only allow authentication without encryption. To use this authentication method, you have to select None as Encryption Type in the credentials for SNMP devices to disable encryption.
To follow up with the NTLM deprecation process from Microsoft and as a first iteration to support Kerberos for WMI sensors, we have implemented a toggle to use WSMan for WMI connections in the PRTG Administration Tool. In the Probe Settings for Monitoring you will see an additional radio button where you can select Use WSMan for WMI connections, however, DCOM is still activated by default. You can set WSMan for WMI connections for each probe.
In the PRTG settings Credentials for Windows Systems you can select the option Only Kerberos as WMI Authentication Method. To use the Only Kerberos setting, please enable the WSMan protocol on the probe system in the PRTG Administration Tool before. You can also select Negotiate (Kerberos, Fallback to NTLM) in the WMI Authentication Method when WSMan protocol is active. In this case, PRTG will establish a connection using Kerberos authentication.
Various other minor fixes and improvements, updated user manual.
We updated the German and Spanish language files.
We updated the German and Spanish language files for certain sensor types.
To give you an improved and accurate view of Maintenance Days Left and Sensors Available, we have removed the widget on the page welcome.htm in PRTG and replaced it with a link to the New UI. The button Need Accurate License Details? links you to the New UI which provides a transparent and consistent overview of sensor usage. In course of this, we have removed the Number of Sensors count on the License Status page in the classic web interface.
Important: You have to enable the PRTG API v2 and New UI on the setup.htm page first to be redirected to the new license overview in the New UI.
We fixed an issue in the PRTG Administration Tool where strings in buttons e.g. were truncated for certain languages. Affected tabs were, for example, PRTG Application Server and NATS Server when you opened the PRTG Administration Tool in German.
We fixed an issue in the device settings for Credentials for Microsoft 365 that occurred when you entered an invalid Tenant ID. In this case, you would receive a bad request error message, however, the changes were saved and you were not able to change any other device settings afterwards.
We fixed an issue for Folder sensors that occurred when you have monitored network shares that contained certain utf-8 special characters in their file names. In the Result of Sensor logfile you could see the following error message: No mapping for the Unicode character exists in the target multi-byte code page.
We fixed an issue for the Ping v2 sensor where the channel Status was not set as primary channel when you had the setting Inverted Error Status enabled.
We fixed an issue for the Microsoft 365 Mailbox sensor when you have selected "...matches regular expression" in the Filter Messages for Subject, Form and Body. The issue occurred in cases when you used an invalid regular expression. The sensor would display an error message that was only partially translated in these cases.
We fixed an issue for the SNMP Disk Free v2 sensor that reported a broken error message and could not read the disk when the disk name contained certain language characters. Any non-conforming character in the disk name is now translated into its hexadecimal representation. Please note that you must recreate the sensor for these changes to take effect.
The SSH Disk Free v2 sensor now detects all available filesystems during sensor creation for Linux distributions. Previously, the sensor did not offer and create all available filesystems as channels like its predecessor SSH Disk Free which resulted in missing channels afterwards.
The configuration file of this version is not downwards compatible with previous PRTG versions.
To update to subsequent PRTG versions, you must first install the following PRTG version: 26.1.116.1532 Stable. PRTG 26.1.116.1532 serves as an intermediate version when you want to update from older PRTG versions to subsequent versions. This step is necessary because we had to update our code signing certificates.
This release contains a new code signing certificate and a corresponding intermediate version which will cause the auto-update process to run two times, please be informed that this could lead to longer update times and multiple reboots.
Important: If you update your PRTG manually, please note that you need to update to the intermediate version 26.1.116.1532 first before you are able to update to the released PRTG version 26.1.118.1380.
We currently face an issue in the PRTG API v2 for the new endpoint
Please note that with PRTG version 26.1.118.1380, the auto-update process takes longer because this version and subsequent ones include the PRTG database and related components, which increase the size of the PRTG installer. We strongly recommend that you do not restart PRTG during this process and wait until the update is complete.
In certain cases, the PRTG core server does not start anymore after updating to PRTG 26.1.118 and the log file core.log contains the message:
The issue mainly affects PRTG installations that are offline or have limited access to the internet and happens if the code signing signature fails due to a missing trust chain in the trusted root certificates of the Windows certificate store.
You can resolve the issue by adding the trusted root certificate for timestamp signature. For more information, see the Knowledge Base article After updating to PRTG 26.1.118, the PRTG core server does not start anymore.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Stable 26.1.118.1380
With this release, version 26.1.118.1381 is also available, as we are currently executing an A/B test. This version will therefore only be displayed for installation if you are in the corresponding group for a PRTG trial installation via website download. Apart from all changes that are included in 26.1.118.1380, this version comes with improvements and new features for our New UI.
With this PRTG version we introduce PRTG Database, developed for data processing and storage in PRTG as a first Beta release. PRTG Database is designed to increase efficiency and speed, especially in large installations with many sensors and data points. It is an alternative to file system storage and uses PostgreSQL to store raw monitoring and configuration data. The PRTG Database will install files and components automatically when you update to this PRTG version, however, it is currently deactivated by default.
Important:
PRTG will create the Database Health (Autonomous) sensor automatically when you update to or install this PRTG version 26.1.117. The sensor is created within the PRTG Core Server group and monitors the PRTG Database service as a first iteration. The sensor will report an error if the PRTG Database service is not running.
You can try out the experimental Proxmox VE Cluster Health sensor (BETA) that monitors the health status of Proxmox VE clusters. Available channels for this sensor type are Quorum Reached, Active Nodes, Online Nodes and Total Nodes. To use this sensor type, please enter the Credentials for Proxmox in the device settings with API token authentication. Please note that the channel Ceph Status is optional and is only available when you have configured a Ceph file system before.
You can try out the Proxmox VE Node Performance sensor that monitors performance metrics and status of Proxmox VE host nodes. To use this sensor type, please enter the Credentials for Proxmox in the device settings with API token authentication.
We improved the SIMATIC S7-300/400 CPU Status sensor (BETA) which now displays the Maximum OB1 Cycle Time in the Specific Sensors Settings if you have set it before during sensor creation. The Maximum OB1 Cycle Time describes the maximum cycle time for the program cycle organization block (OB1) what PRTG uses to calculate the value of the Cycle Ratio channel.
You can try out the experimental SIMATIC S7-300/400 LED Status sensor (BETA) which displays the status of all physical LEDs on the front panel of a SIMATIC S7-300 or S7-400 controller. The sensor will automatically create one channel per LED that is actually available on that monitored PLC model. Depending on the status of the LED, the sensor displays a message for the respective channel, which is mapped via lookup values. For example, Maintenance Required (MAINT) will show the status OK if the LED has the value OFF.
We improved the search method for the SNMP Custom String v2 sensor for search with wildcards and when you have set Interpret Result As to String (default) in the sensor Settings. The sensor has a new setting Search String Contains with the options Simple string (default), Wildcards and Regular expression. You can replace parts of your substring by wildcards, for example ? matches a single character. You can find the returned value in the channel String Found.
You can try out the experimental SSL/TLS Security Check sensor which is the successor to the SSL Security Check sensor. The SSL/TLS Security Check sensor supports modern protocols to ensure secure encrypted connections. Unlike the old sensor, TLS 1.3 is also supported. TLS 1.2 and TLS 1.3 are set as accepted (default) in the sensor settings Security Evaluation, whereas weaker protocols (SSL 3.0, TLS 1.0, TLS 1.1) are set to denied (default). This sensor type can also be created on the Multi-Platform Probe.
We fixed an issue where certain pages were displayed for a few seconds in the classic web interface. This issue happened sporadically and the new UI was displayed after automatic or manual refresh of the pages. This issue could affect the Maps and Reports pages, among others.
You can now enter and save notes in the new Comments tab which we have implemented for each monitoring object (Probe, Group, Device, Sensor level). You will receive a success message after saving your changes. Please note that the new Comments tab is not yet available on Mobile view. If you have existing comments in the classic web interface for that object, you will see the comments now also in the new UI.
We fixed an issue that occurred on the sensor Channel Overview page where unknown errors would be displayed. The issue happened after a certain page refresh interval, that is, after a page refresh you could observe an unknown error message toast.
Start 2026 Strong: Prtg Version 26.1.116 is Now Available in the Stable Release Channel
We're excited to kick off 2026 with the first stable release of the year! PRTG version 26.1.116 is now available and brings you important security improvements, five new experimental sensors (including Proxmox VE and Siemens SIMATIC support), and many fixes and enhancements across the board.
Read the complete blog post hereWe fixed an issue for Single Sign-on where it was not possible to log in with a Single Sign-on user when you updated to the previous PRTG Stable version 26.1.116.1498 and when you had Single Sign-on configured for your PRTG. The login failed and the page no longer worked. The error message too many redirects was displayed in those cases. If necessary, you may need to clear your browser cache and cookies.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Stable 26.1.116.1532
There is an additional installer build 26.2.116.1542 for select distributions, which contains the same content as build 26.1.116.1532.
We have set the HTTPOnly and SameSite flag for the cookies created by PRTG to strengthen secure transmissions.
We improved the security handling for API tokens regarding interactive web sessions by restricting access for API tokens to certain endpoints.
Single Sign-on users are now able to create API keys that can be enabled in the Single Sign-on account settings. As a prerequisite, SSO must be configured in PRTG and an SSO group must exist. You can then enable the new feature Enable API Keys for SSO Users in the Single Sign-on user group settings, which is disabled by default. Additionally, this setting includes a field SSO API Key Lifetime (Days) where you can set the days for how long the API key is valid. When SSO API keys expire after the configured lifetime, the relevant API keys will be cleaned up automatically. As a Single Sign-on user, you can use the SSO API keys also for API authentication.
We have implemented a character limit of 240 characters for the Display Name in the User Account Settings. You cannot save changes if the Display Name exceeds the character limit and you will receive an error with the message The display name cannot exceed 240 characters.
Various other minor fixes and improvements, updated user manual.
We updated the German, Spanish, Dutch and Japanese language files.
We updated the French, Portuguese, Russian, Chinese, Japanese and Dutch language files for certain sensor types.
We fixed an issue for Cloud HTTP v2 sensors that reported the error message The queried field "message" is empty in certain cases. The issue also happened when you monitored different endpoints in various Azure regions.
Your DNS v2 sensor now only accepts IP addresses that exactly match the value you configured in the filter. The previous version did not allow exact matching of the results, which could cause false positive results. For example, an IP address matching the filter with one digit more was also accepted.
We fixed an issue for the HPE 3PAR Drive Enclosure sensor that reported an error with the message Invalid response structure encountered, some data is missing. in certain cases. The sensor log also displayed an invalid showcage command. The issue occurred when you used this sensor type for HPE Primera Storage systems.
We fixed an issue for certain HTTP sensors that were missing in the Add sensor list or stopped working in some cases when you updated to a previous PRTG version. This issue has occurred since PRTG version 25.1.104.1946 and affects the following sensors: HTTP Push Data Advanced, HTTP IoT Push Data Advanced and HTTP Data Advanced sensor. In some cases, an error message was logged if you already had HTTP sensors running in PRTG: Could not load "sensor ID: Osk for httppushdataadvanced was not loaded!
We improved the error handling for file system sensors, for example, Dell EMC Unity File System v2 sensor, to better map error messages like The specified network name is no longer available.
We removed the deprecated setting Basic256 in the Security Policy section of the Credentials for OPC UA. This setting was deprecated due to the used hash algorithm Sha-1. Please note that your OPC UA sensors will report an error message if you have configured the Basic256 setting and update to this PRTG version.
We fixed an issue for the scaling factor sensor channel setting where you can enter a multiplication or division scaling factor for sensors with custom units. The issue occurred, when you have configured a scaling factor for your sensor and at the same time entered channel limits. After saving the changes, you could observe that the channel limits were either divided or multiplied with the value you have entered as scaling factor.
We fixed an issue for the SNMP Windows Service sensor that occurred in certain cases when you have used this sensor type in a device template. For example, when you have configured a device template with the SNMP Windows Service sensor and have set an include/exclude filter for a certain service and run an auto discovery later on a device to create the sensors. When you delete one of those sensors afterwards and run the device template again, the deleted sensors would not be created.
We fixed a compatibility issue for Veeam Backup Job Status and Veeam Backup Job Status Advanced sensors that did not support Veeam 13 for Veeam Backup Enterprise Manager and Backup Server. The sensors reported an error with the message that the JSONPath is incorrect in previous PRTG versions.
We fixed an issue for public Maps that displayed an error Map refresh failed when you configured an External Link before in the Map Designer and clicked on the corresponding object in the public map. This issue also occurred with any Sunburst map object that you have added to your map. Opening the links to the individual objects would also lead to an error.
We currently face an issue for Single Sign-on that does not work anymore when you update to this PRTG version 26.1.116.1498. For Single Sign-on configured with Entra ID in your PRTG, you will see the error message The server terminated an operation because it encountered a client request loop, for example. In the browser you could observe too many redirects and that the page is not working in certain cases. We are working on this issue with high priority.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Stable 26.1.116.1498
You can try out the experimental Proxmox VE Virtual Machine Status (BETA) sensor that monitors performance metrics and status of QEMU virtual machines on Proxmox VE clusters. To use this sensor type, please enter the Credentials for Proxmox in the device settings with API token authentication.
You can try out the experimental Proxmox VE Container Status (BETA) sensor that monitors performance metrics and status of LXC containers on Proxmox VE clusters. To use this sensor type, please enter the Credentials for Proxmox in the device settings with API token authentication.
We implemented a new setting for the SNMP Custom String v2 (BETA) sensor in the Specific Sensor Settings, named Interpret Result as. This setting basically converts the result from the SNMP endpoint into a string. You can select String (default), MAC address and IPv4 address for this setting. The sensor message will then show the format of the setting you have selected before, for example for MAC address it will display "01-02-03-04" as server response.
The Custom v2 sensor now supports string-encoded BITS values, for example MAC addresses, that are converted to a numeric format. Parsed BITS values will work with existing channel configurations.
You can try out the experimental SSL/TLS Certificate sensor (BETA) which is the successor to the SSL Certificate sensor and which was rewritten to also work on the Multi-Platform Probe. This sensor type monitors the certificate of a Secure Sockets Layer (SSL)/Transport Layer Security (TLS) secured connection. Please note that this sensor does not yet support the Use SOCKS proxy setting.
You can try out the experimental SIMATIC S7-300/400 Restart Overview sensor (BETA) that we introduce with this PRTG version. This sensor detects and classifies restart events (cold, warm, hot, planned or unplanned) from legacy Siemens PLCs (Programmable Logic Controller). It helps operations teams understand why and how often a PLC has restarted, which is often critical in diagnosing power losses, software crashes, or watchdog faults. The sensor uses Snap7 and S7 protocol to access the diagnostic buffer of the PLC.
You can try out the experimental SIMATIC S7-300/400 CPU Status sensor (BETA) that we deliver with this PRTG version. This sensor connects to Siemens PLCs (Programmable Logic Controller) using the S7 protocol and reads key diagnostic values like CPU mode (RUN/STOP), OB1 cycle time, cycle load, and recent watchdog events. The data is collected read-only using Snap7 and provides OT teams with remote access to metrics that would otherwise require on-site inspection via TIA Portal.
We fixed an issue for dialogues that disappeared partially behind the resize handler in the split view of the new UI. For example, when you have created a new device, you will receive a pop up dialogue success message object successfully created which could disappear partially behind the resize bars.
We have added the Channel Unit Configuration section to the device settings, where you can configure default units for the channel types Bandwidth, Memory, Disk and File via dropdown menu. You can also use the Inherit From toggle for those settings.
You are now able to delete multiple objects in the Sensor list or Device list via bulk edit selection. You will see a confirmation dialogue that asks you if you want to cancel or confirm the deletion of the selected objects. You will receive an according error message if you do not have the necessary rights to delete certain objects.
We fixed an issue where you could not scroll down in order to see the full message when the sensor reported a down or warning message with a longer text.
Prtg 25.4.114 is Now Available in the Stable Release Channel
We've just released PRTG version 25.4.114 to the stable release channel.
Read the complete blog post here
For further information please also see our Knowledge Base article: Vulnerabilities in PRTG prior v25.4.114.1032
Thanks to USD HeroLabs who made us aware of those vulnerabilities.
We fixed a Denial-of-Service (DoS) vulnerability in the Notification Contacts functionality. An authenticated attacker could cause service disruption. This vulnerability can be tracked under CVE-2025-67835, with severity 3.5 - Low (CVSS v3.1).
For further information please also see our Knowledge Base article: Vulnerabilities in PRTG prior v25.4.114.1032
Thanks to USD HeroLabs who made us aware of the vulnerability.
Various other minor fixes and improvements, updated user manual.
We updated the German and Spanish language files.
We updated the German and Spanish language files for certain sensor types.
We fixed an issue for the VMware Datastore (SOAP) sensor that created an extra non-functioning channel when you have set your PRTG to a different language than English, for example German or Spanish. This channel did not deliver any values and therefore generated an error status, while the actual Free Space channel continued to function. Please note that existing VMware Datastore (SOAP) sensors will still show this extra channel when you update to this PRTG version, the fix applies when you create this sensor type new.
We fixed an issue for the Windows Updates Status (PowerShell) sensor which has been reporting the following error since the last Windows update from October 14th, 2025: Update history does not contain any entries. Please enable the sensor debug options and contact support for further help. The issue happened when your target system was Windows Server 2025 or Windows 11 updated to latest Windows patches.
To update to this Stable 25.4.114.1032 and subsequent PRTG versions, you must first install the following PRTG version: 25.4.112.1189 Stable. PRTG 25.4.112.1189 serves as an intermediate version when you want to update from older PRTG versions to this and subsequent versions. This step is necessary because we had to migrate our codesigning certificates to a new Cloud endpoint.
This release contains a new code signing certificate and a corresponding intermediate version which will cause the auto-update process to run two times, please be informed that this could lead to longer update times and multiple reboots.
Important: If you update your PRTG manually, please note that you need to update to the intermediate version 25.4.112.1189 first before you are able to update to the released PRTG version 25.4.114.1032.
If you are running a canary channel, the auto-update process may run into problems. You need to either switch to the stable channel for one full update cycle or install the newest update by hand since there is no intermediate version for this version channel available, we are sorry for the inconvenience.
In certain cases, the PRTG core server does not start anymore after updating to PRTG 25.4.114 and the log file core.log contains the message:
The issue mainly affects PRTG installations that are offline or have limited access to the internet and happens if the code signing signature fails due to a missing trust chain in the trusted root certificates of the Windows certificate store.
You can resolve the issue by adding the trusted root certificate for timestamp signature. For more information, see the Knowledge Base article After updating to PRTG 25.4.114, the PRTG core server does not start anymore.
We currently face an issue in the Veeam Backup Job Status and Veeam Backup Job Status Advanced sensors that do not yet support Veeam 13 for Veeam Backup Enterprise Manager and Backup Server. If you update your systems to this new Veeam version, the sensors will report an error with the message that the JSONPath is incorrect. When you create new sensors of that type, you will receive the following error message: The meta-analysis returned no valid results. Check if the sensor is compatible with the equipment. (code: PE069) We are currently working on a fix for this issue.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Stable 25.4.114.1032
We fixed an issue for the logout button which was not displayed within the mobile view window and where you had to scroll down to the end of the page in order to logout.