PRTG version 24.2.96.1375 is a maintenance release with several code improvements necessary for upcoming PRTG versions.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Stable 24.2.96.1375
Stable 24.2.96.1346
With this PRTG version we provide various fixes to improve security and stability.
We improved the delivery time for HTTP notifications that took longer in certain cases in the previous PRTG versions when you used a HTTP target URL in the Execute HTTP Action section of the notification template. This issue occurred because the PRTG fallback handling for SSL still tried to establish a TLS secured connection what did not lead to an error but to a longer waiting time for PRTG.
You are now able to create the Ping v2 sensor via device template if you select the option Create Device Template on a device where you can select the Ping v2 sensor in the Create Device Template dialogue window. The Ping v2 sensor left its BETA status with PRTG version 24.1.92.1554 and is now fully supported.
You will now receive a proper error message in the probe adapter log when your NATS server for connection does not offer a secured TLS connection but PRTG is configured to connect with TLS in the Multi-Platform Probe Connection Settings.
Various other minor fixes and improvements, updated user manual.
We updated the German, Spanish, French, Dutch, Portuguese, Japanese, Chinese and Russian language files.
We updated the German and Spanish language files for certain selected sensor types.
We fixed an issue where the button Contact Support was missing in the help bar and also in the Support section on the PRTG Setup page when you ran PRTG with a trial license. This issue also affected Paessler PRTG Hosted Monitor.
We fixed an issue where the API call for api/health.json reported wrongly a disconnected Cluster probe although the probe was connected at this time. You could also see this behavior on the System Status page in PRTG under Probes where the Cluster Probe was reported as not connected yet.
You can now filter for a specific sensor type when you select Add Library Node for your library and when you choose the option Show a collection of filtered sensors and Show only specific sensor types for that node. In previous PRTG versions, when you filtered for the sensor type SSL Certificate sensor, the SSL Security Check sensor would be added to the node as well, for example.
We fixed an issue for public maps access that allowed users to see objects in the device tree despite of their assigned security context when you had two or more public maps open in a tab for map rotation view.
You will no longer receive an error when you click on the button Stop Service or Start Service (ignore changed settings) for the Core and Probe service in the PRTG Administration Tool when you run it as a 64bit version on your system. This issue occurred in the previous PRTG stable version 24.2.94.1400 but did not happen when you run the PRTG Administration Tool in a 32bit mode. The reported error message in this case was One or more required program components of PRTG (PRTG Server.exe, PRTG Probe.exe) could not be found! Please re-run the installation program.
You will now receive proper results from our Help documentation when you click on the More button on the Search Results page. This did not work in the previous PRTG versions and returned the message Your search request did not return any results (Help Documents) when you, for example, searched for the term Core Health. You could also see that your seach term was not resolved properly and displayed as core%20health.
You are now able to send a support bundle with all relevant files via Contact Support button on the Setup page when you are logged in to PRTG with a Single Sign-on user account. In the previous PRTG versions, sending a support bundle as a logged in Single Sign-on user would trigger the overload protection in PRTG and the bundle would not contain any htm files.
We fixed an issue where the returned table for a queried XML was broken when you had an object, e.g. sensor, with a tag that contained an ampersand & in it.
Your Active Directory Replication Errors sensors will now work properly again when you update to this PRTG version. In the previous PRTG versions, the sensor reported the error Replication Neighbor cannot be found in some cases when you updated to PRTG version 23.1.82.2074 and higher. The issue occurred because we improved the method of password transmission for certain sensor types, which could not be handled by the Active Directory Replication Errors sensors correctly.
We fixed an issue for the HTTP v2 sensor that appeared during sensor creation process on the Add Sensor dialog. In the section for HTTP Specific the default URL value would display https://%%host/ instead of https://%host/. This issue also occurred when you added the sensor to your Multi-Platform Probe.
We fixed an issue where in some cases the remote probe reported the status disconnected from time to time when you moved Flow sensors to that specific remote probe or when you had Flow sensors running on that specific remote probe. The issue occurred for sensors, like NetFlow and sFlow sensors, for example. In the Probe.log you could also observe access violations for the FlowProcessor or the FlowSender.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Stable 24.2.96.1315
We fixed an issue for the SNMP Traffic v2 sensor that could not be created in some cases and reported the error message The target system did not return a result for the requested OID.
We implemented the sections for Windows Compatibility Options, SNMP Compatibility Options and Proxy Settings in the device settings in the new UI.
You can now add and edit under Notification settings your notification Schedules, notification Contacts and notification Templates. Please note that this feature is not available on mobile view.
You can now add and edit notification triggers for objects, like probes, groups, devices, and sensors. The notification triggers are available via context menu or Actions button for the relevant object.
You can now edit the settings of a sensor via context menu in the new UI when you right click on the sensor you want to edit. Additionally you can edit the settings of a sensor in the Settings tab or via button Sensor Actions where you can perform actions like Pause Object or Scan Now. After you have saved your changes a growl message appears Settings have been saved. It may take a while for the change to apply.
We fixed an issue where the PRTG application server created a panic log file when you uninstalled PRTG. The error message then reported was Error: could not uninstall system service PRTGAppServer: service PRTGAppServer is not installed. This issue occurred when you uninstalled PRTG without having the PRTG application server installed.
We fixed an issue with PRTG version 24.2.94.1400 where the Probe update to this PRTG version failed and therefore the Probe service(s) did not start in some cases. PRTG would report an error message like PRTG probe service could not be started: The service did not respond to the start or control request in a timely fashion or Windows could not start the PRTG Probe Service service on Local Computer Error 1053: The Service did not respond to the start or could request in a timely fashion when you were affected by this issue. In some rare cases also the Core service was affected when you updated to PRTG stable version 24.2.94.1400. The issue occurred because Windows tried to load the certificate cache what took too long for the Probes during startup and caused a timeout. This issue also affected new installations of PRTG.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Stable 24.2.94.1424
A new PRTG release is available in the stable channel!
Paessler PRTG 24.2.94 has been released in the stable channel! This update brings enhancements for Single Sign-on, new settings for multi-platform probe connections, important security improvements, and updates for the German and Spanish language files. Furthermore, the multi-platform probe is now available as a stable version.
Read the complete blog post hereITOps Board version 3.15.1 comes with Notification improvements. Specifically, if you have configured notifications when an alert is raised for a board or business service, you now receive a notification when the alert is resolved. Additionally, the notifications delivered by email are updated to include more detailed information about the change to the related board or business service.
This release consolidates the location of user access settings, to improve the workflow of the interface. In this release, the settings are consolidated on a new Authorization tab: Roles, Scope Components by Boards and Services, Saved Search Visibility. This version covers also fixed issues. For more information please refer to the release notes provided with the new version.
We are happy to announce that the multi-platform probe has entered its stable status after extensive feedback and testing and it's now recommended for productive use. While the classic remote probe is used on Windows systems, the multi-platform probe allows you to deploy probes on various non-Windows systems. These include Debian, Ubuntu, Redhat, and ARM-based systems.
Key Features:
Upgrade your monitoring capabilities with the multi-platform probe!
For more information about the multi-platform probe and how to use it, please see Multi-Platform Probe for PRTG manual.
For detailed release notes about this release, see our Knowledge Base article: What are the release notes for the Multi-Platform Probe?.
We added the NATS Connection Security toggle in the Multi-Platform Probe Connection Settings to explicitly set the security schema used.
The configuration for connecting the PRTG core server to a NATS server has changed. The schema is now an explicit toggle instead of encoded into the NATS URL. The NATS URL setting was changed to NATS Server Host, which is made up of the hostname and port of the NATS Server. After this update, the NATS Server Host setting will be reset to the default localhost:23561 value and users will need to reconfigure their NATS server.
Important for PRTG Hosted Monitor: This setting is not visible for PRTG Hosted Monitor instances. Customers will be informed separately, as soon as the multi-platform probe can be used with PRTG Hosted Monitor.
Credentials like passwords in the PRTG configuration file are now masked when you use the option Include configuration file (contains passwords) for Send Logs to Paessler in the PRTG Administration Tool in order to send a support bundle. When you have a larger configuration file, e.g. 355 MB and run the PRTG Administration Tool as a 32 bit version, you will receive a message that PRTG was not able to hide encrypted passwords in the configuration file. The same behavior applies when you want to send a support bundle with a broken configuration file. You will then be asked if you still want to include the configuration file containing passwords or not.
Please note that currently is not possible to start the Administration Tool for a Remote Probe running on a 64-bit operating system. As a workaround go to the Program Files (x86) folder, open the PRTG Network Monitor folder, and run the 32-bit version of the Administration tool. We will deliver a fix for this issue in the upcoming PRTG versions.
The behavior of the Environment setting was changed for the EXE/Script and EXE/Script Advanced sensors to prevent remote code execution for Batch (.bat) scripts. Thanks to IT Matters Most GmbH who made us aware of that vulnerability and which can be tracked under CVE-2024-28055, with severity 7.2 AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H. Please note that this change might cause your running custom scripts to fail as it is no longer possible to use the environment variables placeholders in the Parameters setting for Batch (.bat) scripts anymore.
You will now see a log entry in the History tab of a device when you have enabled or disabled the inheritance of an object. For example, if you enable the Inherit From feature toggle for Credentials for Windows Systems, it will be logged as Credentials for Windows Systems: Inherited in the History tab of the device.
We improved the Single Sign-on handling for PRTG user integration in Microsoft Azure AD to support the Microsoft Graph API for paging when a user is assigned to more than 100 groups. Previously, the issue occurred in certain cases that a user with Microsoft Azure AD integration could not log in to PRTG via Single Sign-on when he was assigned to more than 100 groups. Due to limitations in the Access Token concerning the group memberships we need to switch to Microsoft Graph API for paging what was not yet supported by PRTG. The user would then receive the message that the login has failed. In the Core.log you could also find this error message for the user login: is no member of SSO groups allowed by PRTG.
Various other minor fixes and improvements, updated user manual.
We updated the German and Spanish language files.
We updated the Spanish language files for certain selected sensor types.
We changed Bytes (File) to Bytes (Disk) in the Channel Unit Configuration of the VMware Datastore (SOAP) sensor to better match the size of datastores. Please note that this change will come into effect only when you add this sensor type as new and does not affect any existing sensors.
We fixed an issue for the Find Duplicates feature on /api/findduplicates.htm. Previously, if you selected the option Find Duplicates from the device Context menu the result you would have received was empty.
We fixed an issue for the HTTP transaction sensor that could not access a target URL anymore in certain cases and reported the error message String not found in the previous PRTG version, or when you changed to Compatibility engine in the sensor settings the error message was Object reference not set to an instance of an object.
We fixed an issue that could cause a higher memory consumption especially on the Multi-Platform Probe when you ran MQTT sensors and OPC UA sensors on your system. We therefore also updated our MQTT library to version 1.3.13 what patches several issues.
Your Microsoft Azure SQL Database sensor will now report an according sensor message when the monitored single database or elastic pool is in a different state then Online or Ready. Previously, the sensor reported an error message The queried field "average,count,maximum,minimum,total" is empty. when, for example, the queried database was in status Paused.
We fixed an issue for the Oracle SQL v2 sensor that reported an error The type initializer for OracleInternal.Common.ProviderConfig threw an exception when Oracle Data Access Components (ODAC) was installed on the system where also the sensor was added, e.g. on a remote probe. The sensor then went into an error state in this case because one of the Oracle assembly references did not match.
The QoS (Quality of Service) One Way sensor now no longer displays any IP address in the Quality of Service Measurement section for Target Probe when you are about to create this sensor type. Previously, the sensor displayed 127.0.0.1 for the local probe what did not reflect the actual probe ID being used.
The Result of Sensor.txt file will now be updated again when you have activated the Store result option for Debug Options in the sensor Settings. Updating the Result of Sensor.txt file did not work anymore in the previous PRTG versions for certain sensor types. This issue affected sensor types like Traceroute Hop Count sensor, Windows Print Queue sensor and Active Directory Replication Errors sensor, for example.
We fixed an issue where in certain cases the message reported by the sensor suddenly displayed only OK after some time. In these cases the message of the sensor was reverted from the original to OK when the message sent from Probe to Core contained an empty string for some reason. The issue occurred for sensor types like WMI Custom String sensor, SNMP Custom String sensor and REST Custom v2 sensor.
We fixed an issue that occurred for certain sensor types, like the SNMP Custom v2 sensor, where an additional text overlapping the help box was displayed in the section for Schedules, Dependencies and Maintenance Window. Additionally the default dates for Maintenance Begins and Maintenance Ends were not displayed correctly.
We fixed an issue for the SNMP HPE ProLiant Physical Disk Sensor that reported an error Disk: Required field, not defined when you added multiple disks where at least one disk was defective, e.g. did not report serial number and model values. As a result, the sensor could not be created and additionally the PRTG configuration file could also no longer be saved. You will now be able to save your PRTG configuration file again even if your SNMP HPE ProLiant Physical Disk sensor includes a defective disk.
We fixed an issue for the SNMP Memory sensor that reported the error message (value)' is not a valid integer value in certain cases. The issue occurred because certain devices falsely returned counter values instead of integer values for the storage size in the OID 'hrStorageSize' (1.3.6.1.2.1.25.2.3.1.5) what the sensor then could not process correctly.
We fixed an issue for the Windows Print Queue sensor that did not report the correct sensor message when monitored printers were offline or paused. The sensor wrongly reported the status message up in these cases.
We fixed an issue where in certain cases API calls to PRTG failed with the error Unauthorized although the API token was valid. For example, when you use the API endpoint /api/table.json to reach PRTG with a valid created API key, it could happen that the call resulted in an Unauthorized message.
You will now be able to save the settings for all your selected sensors when you use the multi-edit function. This did not work properly before in the previous PRTG versions in certain cases. Saving the value Maximum (Mbit/s) for the channel Traffic Total when you have selected several SNMP Traffic sensors would only work for the first sensor in the list, not for all sensors that you selected via multi-edit.
We fixed an issue for sms notifications that were cut off in the text when you used certain special characters, like for example ampersand &.
We fixed an issue for notification triggers, that is Speed, Volume and Threshold trigger where added values in the PRTG web UI would not be saved correctly in certain cases. It could happen that after you have entered for example a valid value for bit/second in the Speed trigger under Notification Triggers, that the value was saved afterwards with 0 or even an invalid float value. We also fixed this issue for the PRTG App for desktop.
We fixed an issue where not all probe Settings were displayed in the previous PRTG versions when you installed a new remote probe on your system. When you have added a remote probe successfully and opened the probe Settings tab you could see that, for example, the Credentials for Cisco Meraki were missing.
You can now acknowledge alarms with your read-only user in the PRTG App for Desktop when you have set the according rights for that user in the PRTG web interface before. Previously, when you have created a read-only user in PRTG and afterwards added additional rights Allow user to acknowledge alarms to that user, the settings would not automatically be updated when the user was logged in to the PRTG App for Desktop. As a workaround, you had to restart the Core server or the user had to log in to PRTG App for Desktop again.
We fixed an issue where the execution of an auto-discovery with device template on the PRTG App for Desktop produced an access denied message in the CoreWebServer.log.
With this version we discontinue the below already deprecated sensors:
If you run any of these sensor types they will show an error message This sensor type was removed from PRTG. For more information, see https://kb.paessler.com/en/topic/68227. (code:PE258), when you update your PRTG installations to version 24.1.94. You can pause existing sensors afterwards but you will not be able to deploy them anymore.
For further information about sensor deprecation and discontinuation in general as well as successor sensors and sensor alternatives please see our Knowledge Base articles: What do deprecation and discontinuation in the context of sensors mean? and What sensors are deprecated and what are their successors or alternatives?
Currently it is not possible to install or uninstall the PRTG application server via button Install Service or Uninstall Service in the PRTG Administration Tool. The PRTG Administration Tool will execute a Core server restart but the PRTG application server will not be installed or uninstalled afterwards. To install the PRTG application server and make use of the new UI and APIv2, please see our Knowledge Base article: I want to use the new UI and API v2. What do I need to know?
You will receive an error when you click on the button Stop Service or Start Service (ignore changed settings) for the Core and Probe service in the PRTG Administration Tool when you run it as a 64bit version on your system. The PRTG Administration Tool will then report the following: One or more required program components of PRTG (PRTG Server.exe, PRTG Probe.exe) could not be found! Please re-run the installation program. This issues does not occur when you run the PRTG Administration Tool in a 32bit mode. We will deliver a fix for this issue with the upcoming PRTG versions.
Solved with PRTG Stable version 24.2.96.1315
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Stable 24.2.94.1400
You can now configure and manage your Credentials for Windows Systems in the device settings in the new UI and also via API v2. This enables you to use sensors on your device which require windows authentication, like WMI sensors. The available fields are Domain or Computer Name, User Name and Password. You can also see and manage the Inherit From toggle and enable or disable it. The windows credentials will also be visible in the new UI when you set them via APIv2 PATCH request on the endpoint /api/v2/devices/{id}. Additionally you are now able to edit the following device settings in the new UI and APIv2: Credentials for VMware/XenServer, Credentials for AWS, Credentials for Script Sensors, Advanced Network Analysis.
We improved the navigation in the mobile view for the new UI. When you click on the menu icon it opens a drawer from the left hand side. The drawer remains open during navigation and you can close it with the x button. Additionally, when you select home in the side bar, you will see links to the sections Welcome and Quickstart.
We fixed an issue for the PRTG application server that ran into panic mode when you ran a mini probe on your PRTG installation, for example a Python Mini Probe or a PRTG Mobile Probe for Android. The created panic log would display the error panic: runtime error: invalid memory address or nil pointer dereference in these cases.
PRTG release 24.1.92 is available in the stable release channel!
The latest version of Paessler PRTG, 24.1.92, is now available through the stable release channel! This version comes with several new sensor types that are now fully supported (like the Ping v2 sensor, HTTP v2 sensor and SNMP Uptime v2 sensor), an update for OpenSSL, and several other improvements throughout Paessler PRTG.
Read the complete blog post hereThe Cisco Meraki License sensor monitors Meraki licenses of an organization and the Cisco Meraki Network Health sensor monitors the health of Cisco Meraki network devices. Both sensor types use the Cisco Meraki Dashboard API. We released these sensor types as experimental sensors with PRTG version 22.1.74.1869.
This sensor monitors VPN connections of your Fortinet FortiGate firewall. The sensor shows the number of connected SSL clients, as well as the number of both up and down IPsec tunnels. We released this sensor type as experimental sensor with PRTG version 22.1.74.1869.
This sensor allows you to send a HTTP request (HEAD, GET or POST) and use placeholders, similar to the REST Custom v2 sensor. We released this sensor type as experimental sensor with PRTG version 22.4.81.1532.
The Local Folder sensor monitors a local folder on a probe system. We released this sensor type as experimental sensor with PRTG version 21.3.70.1629.
The Network Share sensor monitor a Server Message Block (SMB) or Common Internet File System (CIFS) network share. We released this sensor type as experimental sensor with PRTG version 21.4.73.1656.
The Ping v2 sensor comes with a new setting Inverted Error Status different to its predecessor. If you select Enable for this new setting, the sensor shows a Down status if the target device is reachable. The Ping v2 sensor supports IPv6. We released this sensor type as experimental sensor with PRTG version 22.4.81.1532.
his sensor monitors the virtual disks of your Redfish capable servers and shows capacity and status. We introduced this sensor type as experimental sensor with PRTG version 21.3.71.1416.
This sensor type comes with the same basic settings as the already existing SNMP System Uptime sensor including the additional Data Source setting under the section SNMP Uptime Specific, where you can select the object identifier (OID) the sensor gets its uptime from. The Data source is also depicted in the sensor status. We released this sensor type as experimental sensor with PRTG version 23.2.84.1566.
This sensor monitors the status of processes within an Orchestra scenario. Please note that this sensor requires a Soffico license and as of Orchestra 4.8.2.5. We released this sensor type as experimental sensor with PRTG version 23.4.90.1299.
We improved the creation of API keys via API call requests to match the given access rights. Previously, it was possible to create an API key for a read/write user with the parameter accesslevel_new=full via GET request, although the user only has write access at the most according to the API key access rights settings. The Access Level for the created API key then wrongly displayed full access.
We fixed an issue where an authenticated attacker could craft a specific request against the editlicense.htm endpoint and change the license of PRTG partially affecting the availability of PRTG. The severity is 4.3-Medium and calculated as CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L.
We fixed a reflected XSS vulnerability which allowed JavaScript injection. The severity is 6.1-Medium and calculated as CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N.
We added the option for SNMP Trap notifications to include the sensor ID that triggers the notification in the trap message. If you select the option Include sensor ID in the Send SNMP Trap notification template, PRTG will send it on the OID 1.3.6.1.4.1.32446.1.1.5. Previously, parsing the sent trap messages was not possible for certain third party systems due to the missing option.
To ensure secure communication furthermore we updated to the OpenSSL version 1.1.1w.
Various other minor fixes and improvements, updated user manual.
We updated the German and Spanish language files.
We updated the German and Spanish language files for certain selected sensor types.
You can now send support bundles with the Contact Support option when you have configured a proxy server in the PRTG Core & Probes settings.
Important: The issue still appears in the Paessler PRTG app for desktop.
You will now receive a proper error message Error (Bad Request) again when you enter an invalid (old) password under My Account in your Account Settings. In the previous PRTG version there was a log entry in the Core webserver log Error: The validation of the data you entered has failed, but no corresponding error message in the web interface. The issue occurred when you selected the option Specify a new password and entered an invalid Old password.
We fixed an issue that caused the inheritance to be disabled for all settings of a device if you changed settings in the Device List before. The issue occurred when you selected several devices in the Device List via Settings option in the multi-edit and saved the changes. The settings of the devices where you made the changes for were set to disabled in the Inherit From toggle.
We fixed an issue for historic data reports that displayed not all or additional hours in the Date Time table when the user has set a different time zone under My Account in the PRTG Web Interface. For example, when your time zone in your account was set to (UTC -6:00) and you ran a historic data report for 12 hours, the report would in this case substract the hours in the Date Time table from the UTC time zone set under your account..
We fixed an issue for an unauthorized Ajax error that occurred in certain cases in the CoreWebServer.log instead of displaying the correct error message Your user account is not allowed to access this information. The issue happened when you were logged in with a user account whose assigned user group has write permissions on a library but who is not allowed to access user information when you clicked on the Security Context link for the user to see the User Account Settings.
We fixed an issue for lookup files where changes were not reflected in the web interface when you changed values in lookup files after OID library creation. Changes to lookup values were only displayed after a complete PRTG core server restart. The issue affected for example the SNMP Library sensor, but also other sensors that come with value lookups and appeared only for the first modification in the lookup file.
We fixed an issue where PRTG stored the data for the Installation Path in the same folder as for the Data Path when you selected to run the PRTG installer in the Custom mode for fresh installations since PRTG version 23.3.88. The issue happened when you changed the Data Path directory in the path field directly.
Your remote probes that you have deleted from the device tree will no longer appear on your PRTG Status Page under the Probes and Database Objects sections, or in the information returned when you execute a query on PRTG Health System Information via an API call /api/health.json?. In the previous PRTG version, a deleted remote probe would still be displayed on the mentioned sections with the status disconnected.
You can now sent reports by email again for scheduled reports in the Report Schedule setting. Previously, when the report schedule sent out an email to a configured email address or PRTG user group you would receive an access violation in the Core.log and in certain cases also the message Error sending Report Email. The issue occurred if you selected a schedule for a report in the Report Schedule setting with Target Email Address and/or Email to User Group.
We fixed an issue where you could not save your Scanning Intervals in certain cases when you used a regular interval and a UTC interval with the same unit. For example, if you entered 4h and @UTC 4:00 at the same time in the Available Intervals section you would receive a validation error upon saving your changes.
We fixed an issue for certain sensors on addsensor.htm that could be added although the device or group to which you want to add these sensor types did not have corresponding credentials. When you tried to add an AWS sensor, for example, to a device without Credentials for AWS, you received an error message Sorry, the scan for available monitoring items has failed! The AWS sensors will now be displayed as inactive on addsensor.htm with a hint that valid credentials are needed when you try to add them to a device without Credentials for AWS. This issue was also fixed for the Local Folder sensor (BETA) and the Network Share sensor (BETA).
We fixed an issue that caused the environment variable AWS_EC2_METADATA_DISABLED to be leaked into the environment of other sensors. For example, it did not work in cases when you had PRTG installed on an AWS environment and ran a script with a Python Script sensor that pulled credentials from an API although the role on AWS allowed PRTG to authenticate with an AWS SDK. The environmental variable was set to AWS_EC2_METADATA_DISABLED=TRUE in this case.
Your AWS RDS v2 sensors now display the correct values for the channel Database Connections again. The sensors displayed a wrong amount of connections in the mentioned channel with PRTG stable version 23.4.90.1299 since the sensors pulled the metric for 'SUM' and not 'AVG' (average) for Database Connections.
Your Veeam Backup Job Status Advanced Sensor is now able to display the correct value for the channel Job Scheduled when the scheduled job has been disabled. The channel Job Scheduled will now display the value No where previously the channel would have displayed the value Yes.
For more information please see our Knowledge Base article:https://kb.paessler.com/en/topic/89136 .
We fixed an issue that occurred when you renamed a device or group via context menu in the device tree that contained Credentials for Microsoft 365. The error message was The validation of the data you entered has failed and settings could not be saved when you tried to rename the device or group with right click on edit and rename. The issue also occurred when you tried to edit the access rights in the device tree in these cases.
We fixed an issue where a second tooltip icon with tooltip text was displayed in the section Percentile Handling in the Historic Data Tab of a sensor. You could observe this behavior when you selected the radio button for Show Percentiles. The second tooltip would be displayed for Percentile Averaging Interval.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Stable 24.1.92.1554
The Multi-Platform Probe enables you to deploy probes on platforms not supported by the Remote Probe, including various Linux distributions and ARM hardware.
In this latest release, we provide TLS support, ensuring a secure and encrypted connection to the NATS server. Additionally, we've included a user-friendly setup wizard for the NATS server, streamlining the installation and configuration process.
For more information about the Multi-Platform Probe please see our Knowledge Base article: What is the Multi-Platform Probe and how can I use it?
For detailed release notes please see our Knowledge Base article: What are the release notes for the Multi-Platform Probe?
The Redfish Virtual Disk sensor (BETA) is now able to handle disks that have one of the following states: Enabled, StandbySpare, InTest, Starting, Quiesced, Updating and Qualified. Previously, the sensor could handle only the state Enabled and would display the status offline for all other states.
We improved the security for the usage of Python scripts with the Script v2 sensor. All PYTHON* environment variables that might be set, like PYTHONPATH or PYTHONHOME, will be ignored when you execute scripts with the Script v2 sensor by using the parameter -E. This parameter prevents that a different e.g. PYTHONPATH is set and that Python scripts with potential security issues are run in the Python script directory.
We fixed an issue for the SNMP Uptime v2 (BETA) sensor that displayed wrong values in the Live Data section of the sensor in the System Uptime channel. The issue occurred when you added the sensor to your PRTG local probe, however, it displayed the correct values when you have added it to your Multi-Platform Probe.
We fixed an issue where it was possible to escalate privileges for API-Keys.
We introduced a new header for PRTG in mobile view where the menu is positioned on the top left side. The parent breadcrumb will be displayed on the top right side. The main page title Home was removed.