• Company
    • About Us
    • Press Center
    • Careers
    • Blog
    • IT Knowledge
    • Contact us
  • Contact us
  • Login
 
  • English
    • Deutsch
    • Español
    • Français
    • Italiano
    • Português
Paessler
                    - The Monitoring Experts
  • Products
    • Paessler PRTG
      Paessler PRTGMonitor your whole IT infrastructure
      • PRTG Network Monitor
      • PRTG Enterprise Monitor
      • PRTG Hosted Monitor
      • PRTG MSP Edition
      • PRTG OT Edition
      • PRTG extensionsExtensions for Paessler PRTGExtend your monitoring to a new level
    • Icon Features
      FeaturesExplore all monitoring features
      • Maps & dashboards
      • Alerts & notifications
      • Multiple user interfaces
      • Distributed monitoring
      • Customizable reporting
      • Network Topology
  • Solutions
    • By TeamFor your organization size
      • Small Business IT
      • Mid-Market IT
      • Enterprise IT
      • MSP Network Monitoring
    • Industries
      By IndustryFor your business sector
      • Industrial
      • Healthcare
      • Energy
      • Government
      • Education
      • Data Center
      • Finance
    • IT Topics
      By Use CaseFor every technical scenario
      • Network Monitoring
      • Server Monitoring
      • OT Monitoring
      • Distributed Monitoring
      • Network Topology Mapping
      • SNMP Monitoring
      • Bandwidth Monitoring
  • Pricing
  • Resources
    • Getting Started
      Getting StartedModules for self-paced learning
    • How-to Guides
      How-to GuidesGet the most out of PRTG
    • Videos & Webinars
      Videos & WebinarsLearn from Paessler experts
    • Case StudiesProven results across industries
    • PRTG ManualsAll product documentation
    • Knowledge Base
      Knowledge BaseShare community knowledge
    • PRTG Sensor Hub
      PRTG Sensor HubGet sensors, scripts & templates
    • Trainings
      PRTG TrainingLearn how to work with PRTG
  • Partners
    • Icon Handshake
      Become a PartnerFor resellers and channel partners
    • Icon MSP
      Become an MSPDeliver monitoring as a managed service
    • icon partner
      Partner PortalLog in to your partner account
    • Deal Registration
      Deal RegistrationRegister your sales opportunities
    • icon search
      Find a PartnerFind partners selling Paessler products
    • icon technology
      Technology AlliancesSee Paessler technology partnerships
    • Partner HubTools for Your Success
  • Company
    • About Us
    • Press Center
    • Careers
    • Blog
    • IT Knowledge
    • Contact us
  • Contact us
  • Login
  • English
    • Deutsch
    • Español
    • Français
    • Italiano
    • Português
  • Get a quote
  • Free trial
  1. Home>
  2. Paessler PRTG>
  3. Version history>
  4. Stable release notes

PRTG Release Notes:
Stable Channel

Recommended for Production

  • The stable channel provides the most thoroughly tested PRTG versions. We recommend using stable releases for all live and production environments.
  • To update your PRTG installation, use the Auto-Update feature: In the PRTG web interface, navigate to Setup | Auto Update.
  • You can also download the latest version from the PRTG download page.
  • Want early access to upcoming features? Check out our Preview Release Notes.

PRTG Stable Version 24.2.96.1375

Release date: June 7, 2024
Improved

Improved

MaintenanceVarious

PRTG version 24.2.96.1375 is a maintenance release with several code improvements necessary for upcoming PRTG versions.

Note

Note

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Stable 24.2.96.1375

  • sha256_exe 8C2124ADD6BE4CCD2A83E5B85CA2F34C90EAB26436D7D858DD402086FFBF44F0
  • sha256_zip 9C3FAB3B68726D51EEB6629DD6EA5532D1AB7C866B2E3EF532C6B0127DEDD448

Stable 24.2.96.1346

  • sha256_exe 1B4C10344DC4F7B3D63B6726842A088B448E70E951AF83D5323EF6D16C80B5DC
  • sha256_zip 7473A44270D8D4A0595E9C182DEB4DFEC0E18B3BE15D7FD01719F23178A97E63

PRTG Stable Version 24.2.96.1315

Release date: May 28, 2024
Improved

Improved

WebserverSecurity

With this PRTG version we provide various fixes to improve security and stability.

NotificationsServer

We improved the delivery time for HTTP notifications that took longer in certain cases in the previous PRTG versions when you used a HTTP target URL in the Execute HTTP Action section of the notification template. This issue occurred because the PRTG fallback handling for SSL still tried to establish a TLS secured connection what did not lead to an error but to a longer waiting time for PRTG.

Ping v2Sensors

You are now able to create the Ping v2 sensor via device template if you select the option Create Device Template on a device where you can select the Ping v2 sensor in the Create Device Template dialogue window. The Ping v2 sensor left its BETA status with PRTG version 24.1.92.1554 and is now fully supported.

Probe AdapterMulti-Platform Probe

You will now receive a proper error message in the probe adapter log when your NATS server for connection does not offer a secured TLS connection but PRTG is configured to connect with TLS in the Multi-Platform Probe Connection Settings.

All parts of PRTGVarious

Various other minor fixes and improvements, updated user manual.

LanguagesVarious

We updated the German, Spanish, French, Dutch, Portuguese, Japanese, Chinese and Russian language files.

Sensor languagesVarious

We updated the German and Spanish language files for certain selected sensor types.

Fixed

Fixed

Contact supportServer

We fixed an issue where the button Contact Support was missing in the help bar and also in the Support section on the PRTG Setup page when you ran PRTG with a trial license. This issue also affected Paessler PRTG Hosted Monitor.

ClusterServer

We fixed an issue where the API call for api/health.json reported wrongly a disconnected Cluster probe although the probe was connected at this time. You could also see this behavior on the System Status page in PRTG under Probes where the Cluster Probe was reported as not connected yet.

LibrariesServer

You can now filter for a specific sensor type when you select Add Library Node for your library and when you choose the option Show a collection of filtered sensors and Show only specific sensor types for that node. In previous PRTG versions, when you filtered for the sensor type SSL Certificate sensor, the SSL Security Check sensor would be added to the node as well, for example.

MapsServer

We fixed an issue for public maps access that allowed users to see objects in the device tree despite of their assigned security context when you had two or more public maps open in a tab for map rotation view.

PRTG Administration ToolServer

You will no longer receive an error when you click on the button Stop Service or Start Service (ignore changed settings) for the Core and Probe service in the PRTG Administration Tool when you run it as a 64bit version on your system. This issue occurred in the previous PRTG stable version 24.2.94.1400 but did not happen when you run the PRTG Administration Tool in a 32bit mode. The reported error message in this case was One or more required program components of PRTG (PRTG Server.exe, PRTG Probe.exe) could not be found! Please re-run the installation program.

SearchServer

You will now receive proper results from our Help documentation when you click on the More button on the Search Results page. This did not work in the previous PRTG versions and returned the message Your search request did not return any results (Help Documents) when you, for example, searched for the term Core Health. You could also see that your seach term was not resolved properly and displayed as core%20health.

Single Sign-onServer

You are now able to send a support bundle with all relevant files via Contact Support button on the Setup page when you are logged in to PRTG with a Single Sign-on user account. In the previous PRTG versions, sending a support bundle as a logged in Single Sign-on user would trigger the overload protection in PRTG and the bundle would not contain any htm files.

XML tablesServer

We fixed an issue where the returned table for a queried XML was broken when you had an object, e.g. sensor, with a tag that contained an ampersand & in it.

Active Directory Replication ErrorsSensors

Your Active Directory Replication Errors sensors will now work properly again when you update to this PRTG version. In the previous PRTG versions, the sensor reported the error Replication Neighbor cannot be found in some cases when you updated to PRTG version 23.1.82.2074 and higher. The issue occurred because we improved the method of password transmission for certain sensor types, which could not be handled by the Active Directory Replication Errors sensors correctly.

HTTP v2Sensors

We fixed an issue for the HTTP v2 sensor that appeared during sensor creation process on the Add Sensor dialog. In the section for HTTP Specific the default URL value would display https://%%host/ instead of https://%host/. This issue also occurred when you added the sensor to your Multi-Platform Probe.

NetFlow sensorsSensors

We fixed an issue where in some cases the remote probe reported the status disconnected from time to time when you moved Flow sensors to that specific remote probe or when you had Flow sensors running on that specific remote probe. The issue occurred for sensors, like NetFlow and sFlow sensors, for example. In the Probe.log you could also observe access violations for the FlowProcessor or the FlowSender.

Note

Note

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Stable 24.2.96.1315

  • sha256_exe D0DA0003C068800D38C5F65DD5EFD57D91B96FE83D12D67BC675C69BF9B1AF29
  • sha256_zip CE60F73C75A37CFD44471330B05DA28AB712FFD06452670584234CCC6A9CB82A
Lab

Lab

SNMP Traffic v2Sensors

We fixed an issue for the SNMP Traffic v2 sensor that could not be created in some cases and reported the error message The target system did not return a result for the requested OID.

Device settingsNew UI

We implemented the sections for Windows Compatibility Options, SNMP Compatibility Options and Proxy Settings in the device settings in the new UI.

NotificationsNew UI

You can now add and edit under Notification settings your notification Schedules, notification Contacts and notification Templates. Please note that this feature is not available on mobile view.

Notification triggerNew UI

You can now add and edit notification triggers for objects, like probes, groups, devices, and sensors. The notification triggers are available via context menu or Actions button for the relevant object.

Sensor settingsNew UI

You can now edit the settings of a sensor via context menu in the new UI when you right click on the sensor you want to edit. Additionally you can edit the settings of a sensor in the Settings tab or via button Sensor Actions where you can perform actions like Pause Object or Scan Now. After you have saved your changes a growl message appears Settings have been saved. It may take a while for the change to apply.

APIPRTG API v2
  • You can now send GET requests to the following endpoints api/v2/groups/{id}, api/v2/sensors/{id} and api/v2/probes/{id} to receive relevant information about these objects.
  • You are now able to clone objects (group, device, sensor) via PRTG APIv2 POST request and the endpoint object name/id/clone. The settings of the cloned object will have the same settings as the original object. A cloned sensor, for example, has the default name 'Clone of '. After you have cloned an object it is paused by default. Here the same clone rules apply as for the classic PRTG UI, that means you cannot clone fixed objects such as the root group, a probe device, or PRTG system-internal sensors. When you have entered a wrong object ID for cloning, the response will return a 404 not found error message.
PRTG application serverPRTG API v2

We fixed an issue where the PRTG application server created a panic log file when you uninstalled PRTG. The error message then reported was Error: could not uninstall system service PRTGAppServer: service PRTGAppServer is not installed. This issue occurred when you uninstalled PRTG without having the PRTG application server installed.

PRTG Stable Version 24.2.94.1424

Release date: May 2, 2024
Fixed

Fixed

PRTG Probe ServiceServer

We fixed an issue with PRTG version 24.2.94.1400 where the Probe update to this PRTG version failed and therefore the Probe service(s) did not start in some cases. PRTG would report an error message like PRTG probe service could not be started: The service did not respond to the start or control request in a timely fashion or Windows could not start the PRTG Probe Service service on Local Computer Error 1053: The Service did not respond to the start or could request in a timely fashion when you were affected by this issue. In some rare cases also the Core service was affected when you updated to PRTG stable version 24.2.94.1400. The issue occurred because Windows tried to load the certificate cache what took too long for the Probes during startup and caused a timeout. This issue also affected new installations of PRTG.

Note

Note

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Stable 24.2.94.1424

  • sha256_exe 4E31AA98E569A9E3573AEA848E7B9EA2D1052CADC7371006F48D94302ED1BC18
  • sha256_zip CBA20E47011623CC98012BA158E335A9C001769508C633D4ECC589D201E69C07

PRTG Stable Version 24.2.94.1400

Release date: April 10, 2024

Blog article

Michael BeckerBy Michael Becker•Aug 12, 2024

A new PRTG release is available in the stable channel!

Paessler PRTG 24.2.94 has been released in the stable channel! This update brings enhancements for Single Sign-on, new settings for multi-platform probe connections, important security improvements, and updates for the German and Spanish language files. Furthermore, the multi-platform probe is now available as a stable version.

Read the complete blog post here
A new PRTG release is available in the stable channel!
New

New

Improvements and FixesITOps Board

ITOps Board version 3.15.1 comes with Notification improvements. Specifically, if you have configured notifications when an alert is raised for a board or business service, you now receive a notification when the alert is resolved. Additionally, the notifications delivered by email are updated to include more detailed information about the change to the related board or business service.

This release consolidates the location of user access settings, to improve the workflow of the interface. In this release, the settings are consolidated on a new Authorization tab: Roles, Scope Components by Boards and Services, Saved Search Visibility. This version covers also fixed issues. For more information please refer to the release notes provided with the new version.

Multi-Platform Probe ReleaseMulti-Platform Probe

We are happy to announce that the multi-platform probe has entered its stable status after extensive feedback and testing and it's now recommended for productive use. While the classic remote probe is used on Windows systems, the multi-platform probe allows you to deploy probes on various non-Windows systems. These include Debian, Ubuntu, Redhat, and ARM-based systems.

Key Features:

  • Cross-platform compatibility: Deploy probes on various non-Windows operating systems.
  • Enhanced stability: The multi-platform probe has undergone rigorous testing to ensure stability and reliability.
  • Expanded use cases: Unlock new possibilities by utilizing sensors and probes on diverse platforms.

Upgrade your monitoring capabilities with the multi-platform probe!

For more information about the multi-platform probe and how to use it, please see Multi-Platform Probe for PRTG manual.

For detailed release notes about this release, see our Knowledge Base article: What are the release notes for the Multi-Platform Probe?.

Probe AdapterMulti-Platform Probe
  • You will now need to configure the probe adapter connection to the NATS server through the PRTG web interface. You can set up your probe adapter configuration in the Core & Probes tab of the System Administration in the Multi-Platform Probe Connection Settings section. In this section you can choose the Multi-Platform Probe Connections, add a NATS Server URL, NATS Server Name, NATS Password, choose the NATS Server Certificate Authority Handling and finally choose the Connection Log Level where you can define the log severity level to determine which logs appear in the probe adapter log file. For this field you can choose one of the options offered from a dropdown menu: Error, Warning, Info (default), Debug, Trace.
  • With this PRTG version we introduce a new Multi-Platform Probe Connection Health (Autonomous) sensor that will inform you of the NATS server connection with your Multi-Platform probe and is created automatically when you have activated Allow multi-platform probe connections in the Core & Probes settings of your PRTG installation. The sensor comes with the channel NATS Connection state that has the lookup values Disabled, Connected and Disconnected. When you have disabled the setting for Allow multi-platform probe connections the sensor will display an according error message and return the value Disabled.

    Please note that the sensor is in BETA status but you do not need to enable the BETA feature in order to get this sensor created. This sensor type only concerns the connection between Probe Adapter and NATS server.
Multi-Platform Probe Connection settingsMulti-Platform Probe

We added the NATS Connection Security toggle in the Multi-Platform Probe Connection Settings to explicitly set the security schema used. The configuration for connecting the PRTG core server to a NATS server has changed. The schema is now an explicit toggle instead of encoded into the NATS URL. The NATS URL setting was changed to NATS Server Host, which is made up of the hostname and port of the NATS Server. After this update, the NATS Server Host setting will be reset to the default localhost:23561 value and users will need to reconfigure their NATS server.

Important for PRTG Hosted Monitor: This setting is not visible for PRTG Hosted Monitor instances. Customers will be informed separately, as soon as the multi-platform probe can be used with PRTG Hosted Monitor.

Improved

Improved

PRTG configuration fileSecurity

Credentials like passwords in the PRTG configuration file are now masked when you use the option Include configuration file (contains passwords) for Send Logs to Paessler in the PRTG Administration Tool in order to send a support bundle. When you have a larger configuration file, e.g. 355 MB and run the PRTG Administration Tool as a 32 bit version, you will receive a message that PRTG was not able to hide encrypted passwords in the configuration file. The same behavior applies when you want to send a support bundle with a broken configuration file. You will then be asked if you still want to include the configuration file containing passwords or not.

Please note that currently is not possible to start the Administration Tool for a Remote Probe running on a 64-bit operating system. As a workaround go to the Program Files (x86) folder, open the PRTG Network Monitor folder, and run the 32-bit version of the Administration tool. We will deliver a fix for this issue in the upcoming PRTG versions.

SensorsSecurity

The behavior of the Environment setting was changed for the EXE/Script and EXE/Script Advanced sensors to prevent remote code execution for Batch (.bat) scripts. Thanks to IT Matters Most GmbH who made us aware of that vulnerability and which can be tracked under CVE-2024-28055, with severity 7.2 AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H. Please note that this change might cause your running custom scripts to fail as it is no longer possible to use the environment variables placeholders in the Parameters setting for Batch (.bat) scripts anymore.

WebserverSecurity
  • We hardened PRTG against possible Cross-Site Scripting attacks via User Agent in the browser.
  • We fixed an open redirect which could potentially be used for phishing and other purposes. The severity is 4.3-Medium and calculated as CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N.
  • We hardened PRTG against possible Cross-Site Scripting (XSS) attacks during Probe creation. The severity is 6.9-Medium and calculated as CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:H/A:N.
LoggingServer

You will now see a log entry in the History tab of a device when you have enabled or disabled the inheritance of an object. For example, if you enable the Inherit From feature toggle for Credentials for Windows Systems, it will be logged as Credentials for Windows Systems: Inherited in the History tab of the device.

Single Sign-onServer

We improved the Single Sign-on handling for PRTG user integration in Microsoft Azure AD to support the Microsoft Graph API for paging when a user is assigned to more than 100 groups. Previously, the issue occurred in certain cases that a user with Microsoft Azure AD integration could not log in to PRTG via Single Sign-on when he was assigned to more than 100 groups. Due to limitations in the Access Token concerning the group memberships we need to switch to Microsoft Graph API for paging what was not yet supported by PRTG. The user would then receive the message that the login has failed. In the Core.log you could also find this error message for the user login: is no member of SSO groups allowed by PRTG.

All parts of PRTGVarious

Various other minor fixes and improvements, updated user manual.

LanguagesVarious

We updated the German and Spanish language files.

Sensor languagesVarious

We updated the Spanish language files for certain selected sensor types.

Changed

Changed

VMware Datastore (SOAP) sensorSensors

We changed Bytes (File) to Bytes (Disk) in the Channel Unit Configuration of the VMware Datastore (SOAP) sensor to better match the size of datastores. Please note that this change will come into effect only when you add this sensor type as new and does not affect any existing sensors.

Fixed

Fixed

Find duplicatesWeb GUI

We fixed an issue for the Find Duplicates feature on /api/findduplicates.htm. Previously, if you selected the option Find Duplicates from the device Context menu the result you would have received was empty.

HTTP Transaction sensorSensors

We fixed an issue for the HTTP transaction sensor that could not access a target URL anymore in certain cases and reported the error message String not found in the previous PRTG version, or when you changed to Compatibility engine in the sensor settings the error message was Object reference not set to an instance of an object.

MemorySensors

We fixed an issue that could cause a higher memory consumption especially on the Multi-Platform Probe when you ran MQTT sensors and OPC UA sensors on your system. We therefore also updated our MQTT library to version 1.3.13 what patches several issues.

Microsoft Azure SQL Database sensorSensors

Your Microsoft Azure SQL Database sensor will now report an according sensor message when the monitored single database or elastic pool is in a different state then Online or Ready. Previously, the sensor reported an error message The queried field "average,count,maximum,minimum,total" is empty. when, for example, the queried database was in status Paused.

Oracle SQL v2Sensors

We fixed an issue for the Oracle SQL v2 sensor that reported an error The type initializer for OracleInternal.Common.ProviderConfig threw an exception when Oracle Data Access Components (ODAC) was installed on the system where also the sensor was added, e.g. on a remote probe. The sensor then went into an error state in this case because one of the Oracle assembly references did not match.

QoS (Quality of Service) One Way sensorSensors

The QoS (Quality of Service) One Way sensor now no longer displays any IP address in the Quality of Service Measurement section for Target Probe when you are about to create this sensor type. Previously, the sensor displayed 127.0.0.1 for the local probe what did not reflect the actual probe ID being used.

Sensor logsSensors

The Result of Sensor.txt file will now be updated again when you have activated the Store result option for Debug Options in the sensor Settings. Updating the Result of Sensor.txt file did not work anymore in the previous PRTG versions for certain sensor types. This issue affected sensor types like Traceroute Hop Count sensor, Windows Print Queue sensor and Active Directory Replication Errors sensor, for example.

Sensor messageSensors

We fixed an issue where in certain cases the message reported by the sensor suddenly displayed only OK after some time. In these cases the message of the sensor was reverted from the original to OK when the message sent from Probe to Core contained an empty string for some reason. The issue occurred for sensor types like WMI Custom String sensor, SNMP Custom String sensor and REST Custom v2 sensor.

Sensor settingsSensors

We fixed an issue that occurred for certain sensor types, like the SNMP Custom v2 sensor, where an additional text overlapping the help box was displayed in the section for Schedules, Dependencies and Maintenance Window. Additionally the default dates for Maintenance Begins and Maintenance Ends were not displayed correctly.

SNMP HPE ProLiant Physical Disk SensorSensors

We fixed an issue for the SNMP HPE ProLiant Physical Disk Sensor that reported an error Disk: Required field, not defined when you added multiple disks where at least one disk was defective, e.g. did not report serial number and model values. As a result, the sensor could not be created and additionally the PRTG configuration file could also no longer be saved. You will now be able to save your PRTG configuration file again even if your SNMP HPE ProLiant Physical Disk sensor includes a defective disk.

SNMP Memory sensorSensors

We fixed an issue for the SNMP Memory sensor that reported the error message (value)' is not a valid integer value in certain cases. The issue occurred because certain devices falsely returned counter values instead of integer values for the storage size in the OID 'hrStorageSize' (1.3.6.1.2.1.25.2.3.1.5) what the sensor then could not process correctly.

Windows Print Queue sensorSensors

We fixed an issue for the Windows Print Queue sensor that did not report the correct sensor message when monitored printers were offline or paused. The sensor wrongly reported the status message up in these cases.

APIServer

We fixed an issue where in certain cases API calls to PRTG failed with the error Unauthorized although the API token was valid. For example, when you use the API endpoint /api/table.json to reach PRTG with a valid created API key, it could happen that the call resulted in an Unauthorized message.

MapsServer
  • We fixed an issue where the public map display resulted in an empty window if a read-only user had access only to one object on the map. The issue occurred when the objects were linked with a connector and the read-only user had access only to one of these objects. When the map was opened in a separate incognito window with the option Public Access without login, it would only display an empty page, although the Security Context was set to the read-only user.
  • Your public map display will now work properly again when you are logged in to PRTG with a user that has No access to the relevant map. Previously, when you opened a map with the link for Public Access and you were logged in to PRTG with a user that has No access under Access Rights for the map, the page would then display Map refresh failed, although the map was configured for public access.
Multi-editServer

You will now be able to save the settings for all your selected sensors when you use the multi-edit function. This did not work properly before in the previous PRTG versions in certain cases. Saving the value Maximum (Mbit/s) for the channel Traffic Total when you have selected several SNMP Traffic sensors would only work for the first sensor in the list, not for all sensors that you selected via multi-edit.

NotificationsServer

We fixed an issue for sms notifications that were cut off in the text when you used certain special characters, like for example ampersand &.

Notification triggerServer

We fixed an issue for notification triggers, that is Speed, Volume and Threshold trigger where added values in the PRTG web UI would not be saved correctly in certain cases. It could happen that after you have entered for example a valid value for bit/second in the Speed trigger under Notification Triggers, that the value was saved afterwards with 0 or even an invalid float value. We also fixed this issue for the PRTG App for desktop.

Remote probesServer

We fixed an issue where not all probe Settings were displayed in the previous PRTG versions when you installed a new remote probe on your system. When you have added a remote probe successfully and opened the probe Settings tab you could see that, for example, the Credentials for Cisco Meraki were missing.

Access rightsPRTG App for Desktop

You can now acknowledge alarms with your read-only user in the PRTG App for Desktop when you have set the according rights for that user in the PRTG web interface before. Previously, when you have created a read-only user in PRTG and afterwards added additional rights Allow user to acknowledge alarms to that user, the settings would not automatically be updated when the user was logged in to the PRTG App for Desktop. As a workaround, you had to restart the Core server or the user had to log in to PRTG App for Desktop again.

Auto-DiscoveryPRTG App for Desktop

We fixed an issue where the execution of an auto-discovery with device template on the PRTG App for Desktop produced an access denied message in the CoreWebServer.log.

Note

Note

Discontinued sensors with PRTG 24.2.94Sensors

With this version we discontinue the below already deprecated sensors:

  • Amazon CloudWatch sensors (announced as deprecated with PRTG version 22.3.78.1873)
  • Cloud HTTP sensor and Cloud Ping sensor (announced as deprecated with PRTG version 22.3.78.1873)
  • DNS sensor (announced as deprecated with PRTG version 21.2.69.1308)
  • REST Dell EMC sensors (announced as deprecated with PRTG version 21.2.67.1531)

If you run any of these sensor types they will show an error message This sensor type was removed from PRTG. For more information, see https://kb.paessler.com/en/topic/68227. (code:PE258), when you update your PRTG installations to version 24.1.94. You can pause existing sensors afterwards but you will not be able to deploy them anymore.

For further information about sensor deprecation and discontinuation in general as well as successor sensors and sensor alternatives please see our Knowledge Base articles: What do deprecation and discontinuation in the context of sensors mean? and What sensors are deprecated and what are their successors or alternatives?

PRTG application serverKnown Issues

Currently it is not possible to install or uninstall the PRTG application server via button Install Service or Uninstall Service in the PRTG Administration Tool. The PRTG Administration Tool will execute a Core server restart but the PRTG application server will not be installed or uninstalled afterwards. To install the PRTG application server and make use of the new UI and APIv2, please see our Knowledge Base article: I want to use the new UI and API v2. What do I need to know?

PRTG Administration ToolKnown Issues

You will receive an error when you click on the button Stop Service or Start Service (ignore changed settings) for the Core and Probe service in the PRTG Administration Tool when you run it as a 64bit version on your system. The PRTG Administration Tool will then report the following: One or more required program components of PRTG (PRTG Server.exe, PRTG Probe.exe) could not be found! Please re-run the installation program. This issues does not occur when you run the PRTG Administration Tool in a 32bit mode. We will deliver a fix for this issue with the upcoming PRTG versions.

Solved with PRTG Stable version 24.2.96.1315

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Stable 24.2.94.1400

  • sha256_exe CBC38F35BC3B4F557FE90EE9EAEEC8E1E66D852713A947119D477844D7E0E7D8
  • sha256_zip 483CD024BD41BF522292A52C65EB09316518030455362423FC60EFC59354C3F5
Lab

Lab

Device settingsNew UI

You can now configure and manage your Credentials for Windows Systems in the device settings in the new UI and also via API v2. This enables you to use sensors on your device which require windows authentication, like WMI sensors. The available fields are Domain or Computer Name, User Name and Password. You can also see and manage the Inherit From toggle and enable or disable it. The windows credentials will also be visible in the new UI when you set them via APIv2 PATCH request on the endpoint /api/v2/devices/{id}. Additionally you are now able to edit the following device settings in the new UI and APIv2: Credentials for VMware/XenServer, Credentials for AWS, Credentials for Script Sensors, Advanced Network Analysis.

Mobile viewNew UI

We improved the navigation in the mobile view for the new UI. When you click on the menu icon it opens a drawer from the left hand side. The drawer remains open during navigation and you can close it with the x button. Additionally, when you select home in the side bar, you will see links to the sections Welcome and Quickstart.

APIPRTG API v2
  • We fixed an issue where it was possible to pause a user via the endpoint api/v2/users/ID/pause. The user was successfully paused and was no longer able to log in. This issue did not affect the old APIv1.
  • We fixed an issue where the status info of a device was displayed when you have paused it before and now resumed it via POST request devices/id/resume. The status info would then display status:UP when you executed a GET request on devices/id. The status info will now only be displayed when you have paused a device.
  • The PATCH and POST endpoints can now handle incoming setting lookup values. For example, for the POST endpoint experimental/groups/{id}/device you can now send the discoverytypegroup for a device template.
  • We fixed an issue where executing the request via endpoint GET users/{userId}/api-keys resulted in a not found error message when you used a newly created API key that you created before in the PRTG classic web interface.
  • We fixed an issue for the devices/{id} endpoint where executing a PATCH request to rename a device was only changed in the basic section.
PRTG application serverPRTG API v2

We fixed an issue for the PRTG application server that ran into panic mode when you ran a mini probe on your PRTG installation, for example a Python Mini Probe or a PRTG Mobile Probe for Android. The created panic log would display the error panic: runtime error: invalid memory address or nil pointer dereference in these cases.

PRTG Stable Version 24.1.92.1554

Release date: February 14, 2024

Blog article

Michael BeckerBy Michael Becker•Aug 13, 2024

PRTG release 24.1.92 is available in the stable release channel!

The latest version of Paessler PRTG, 24.1.92, is now available through the stable release channel! This version comes with several new sensor types that are now fully supported (like the Ping v2 sensor, HTTP v2 sensor and SNMP Uptime v2 sensor), an update for OpenSSL, and several other improvements throughout Paessler PRTG.

Read the complete blog post here
PRTG release 24.1.92 is available in the stable release channel!
New

New

Cisco Meraki sensorsSensors

The Cisco Meraki License sensor monitors Meraki licenses of an organization and the Cisco Meraki Network Health sensor monitors the health of Cisco Meraki network devices. Both sensor types use the Cisco Meraki Dashboard API. We released these sensor types as experimental sensors with PRTG version 22.1.74.1869.

FortiGate VPN Overview sensorSensors

This sensor monitors VPN connections of your Fortinet FortiGate firewall. The sensor shows the number of connected SSL clients, as well as the number of both up and down IPsec tunnels. We released this sensor type as experimental sensor with PRTG version 22.1.74.1869.

HTTP v2 sensorSensors

This sensor allows you to send a HTTP request (HEAD, GET or POST) and use placeholders, similar to the REST Custom v2 sensor. We released this sensor type as experimental sensor with PRTG version 22.4.81.1532.

Local Folder sensorSensors

The Local Folder sensor monitors a local folder on a probe system. We released this sensor type as experimental sensor with PRTG version 21.3.70.1629.

Network Share sensorSensors

The Network Share sensor monitor a Server Message Block (SMB) or Common Internet File System (CIFS) network share. We released this sensor type as experimental sensor with PRTG version 21.4.73.1656.

Ping v2 sensorSensors

The Ping v2 sensor comes with a new setting Inverted Error Status different to its predecessor. If you select Enable for this new setting, the sensor shows a Down status if the target device is reachable. The Ping v2 sensor supports IPv6. We released this sensor type as experimental sensor with PRTG version 22.4.81.1532.

Redfish Virtual Disk sensorSensors

his sensor monitors the virtual disks of your Redfish capable servers and shows capacity and status. We introduced this sensor type as experimental sensor with PRTG version 21.3.71.1416.

SNMP Uptime v2Sensors

This sensor type comes with the same basic settings as the already existing SNMP System Uptime sensor including the additional Data Source setting under the section SNMP Uptime Specific, where you can select the object identifier (OID) the sensor gets its uptime from. The Data source is also depicted in the sensor status. We released this sensor type as experimental sensor with PRTG version 23.2.84.1566.

Soffico Orchestra Scenario sensorSensors

This sensor monitors the status of processes within an Orchestra scenario. Please note that this sensor requires a Soffico license and as of Orchestra 4.8.2.5. We released this sensor type as experimental sensor with PRTG version 23.4.90.1299.

Improved

Improved

API KeysSecurity

We improved the creation of API keys via API call requests to match the given access rights. Previously, it was possible to create an API key for a read/write user with the parameter accesslevel_new=full via GET request, although the user only has write access at the most according to the API key access rights settings. The Access Level for the created API key then wrongly displayed full access.

Web interfaceSecurity

We fixed an issue where an authenticated attacker could craft a specific request against the editlicense.htm endpoint and change the license of PRTG partially affecting the availability of PRTG. The severity is 4.3-Medium and calculated as CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L.

WebserverSecurity

We fixed a reflected XSS vulnerability which allowed JavaScript injection. The severity is 6.1-Medium and calculated as CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N.

NotificationsServer

We added the option for SNMP Trap notifications to include the sensor ID that triggers the notification in the trap message. If you select the option Include sensor ID in the Send SNMP Trap notification template, PRTG will send it on the OID 1.3.6.1.4.1.32446.1.1.5. Previously, parsing the sent trap messages was not possible for certain third party systems due to the missing option.

Update to OpenSSL 1.1.1wServer

To ensure secure communication furthermore we updated to the OpenSSL version 1.1.1w.

All parts of PRTGVarious

Various other minor fixes and improvements, updated user manual.

LanguagesVarious

We updated the German and Spanish language files.

Sensor LanguagesVarious

We updated the German and Spanish language files for certain selected sensor types.

Fixed

Fixed

Contact SupportServer

You can now send support bundles with the Contact Support option when you have configured a proxy server in the PRTG Core & Probes settings.

Important: The issue still appears in the Paessler PRTG app for desktop.

Change PasswordServer

You will now receive a proper error message Error (Bad Request) again when you enter an invalid (old) password under My Account in your Account Settings. In the previous PRTG version there was a log entry in the Core webserver log Error: The validation of the data you entered has failed, but no corresponding error message in the web interface. The issue occurred when you selected the option Specify a new password and entered an invalid Old password.

Device ListServer

We fixed an issue that caused the inheritance to be disabled for all settings of a device if you changed settings in the Device List before. The issue occurred when you selected several devices in the Device List via Settings option in the multi-edit and saved the changes. The settings of the devices where you made the changes for were set to disabled in the Inherit From toggle.

Historic Data reportsServer

We fixed an issue for historic data reports that displayed not all or additional hours in the Date Time table when the user has set a different time zone under My Account in the PRTG Web Interface. For example, when your time zone in your account was set to (UTC -6:00) and you ran a historic data report for 12 hours, the report would in this case substract the hours in the Date Time table from the UTC time zone set under your account..

LibrariesServer

We fixed an issue for an unauthorized Ajax error that occurred in certain cases in the CoreWebServer.log instead of displaying the correct error message Your user account is not allowed to access this information. The issue happened when you were logged in with a user account whose assigned user group has write permissions on a library but who is not allowed to access user information when you clicked on the Security Context link for the user to see the User Account Settings.

LookupsServer

We fixed an issue for lookup files where changes were not reflected in the web interface when you changed values in lookup files after OID library creation. Changes to lookup values were only displayed after a complete PRTG core server restart. The issue affected for example the SNMP Library sensor, but also other sensors that come with value lookups and appeared only for the first modification in the lookup file.

MapsServer
  • We fixed an issue for public maps where the map access failed with the error message Map refresh failed in certain cases. The issue occurred for read-only users that had Read Access to a public map in the according PRTG User Group but different security contexts, for example No Access, for objects in a public map. Public maps are now displayed for read-only users but only show the objects the read-only users have access to according to the security context.
  • You can again change the background image of a Map in the Map Settings. If you changed the background image of your map and saved the changes, the map would still display the old image as the new one was saved under an incorrect map ID in the previous PRTG version.
PRTG InstallerServer

We fixed an issue where PRTG stored the data for the Installation Path in the same folder as for the Data Path when you selected to run the PRTG installer in the Custom mode for fresh installations since PRTG version 23.3.88. The issue happened when you changed the Data Path directory in the path field directly.

Remote ProbesServer

Your remote probes that you have deleted from the device tree will no longer appear on your PRTG Status Page under the Probes and Database Objects sections, or in the information returned when you execute a query on PRTG Health System Information via an API call /api/health.json?. In the previous PRTG version, a deleted remote probe would still be displayed on the mentioned sections with the status disconnected.

ReportsServer

You can now sent reports by email again for scheduled reports in the Report Schedule setting. Previously, when the report schedule sent out an email to a configured email address or PRTG user group you would receive an access violation in the Core.log and in certain cases also the message Error sending Report Email. The issue occurred if you selected a schedule for a report in the Report Schedule setting with Target Email Address and/or Email to User Group.

Scanning IntervalServer

We fixed an issue where you could not save your Scanning Intervals in certain cases when you used a regular interval and a UTC interval with the same unit. For example, if you entered 4h and @UTC 4:00 at the same time in the Available Intervals section you would receive a validation error upon saving your changes.

Add sensorSensors

We fixed an issue for certain sensors on addsensor.htm that could be added although the device or group to which you want to add these sensor types did not have corresponding credentials. When you tried to add an AWS sensor, for example, to a device without Credentials for AWS, you received an error message Sorry, the scan for available monitoring items has failed! The AWS sensors will now be displayed as inactive on addsensor.htm with a hint that valid credentials are needed when you try to add them to a device without Credentials for AWS. This issue was also fixed for the Local Folder sensor (BETA) and the Network Share sensor (BETA).

AWS sensorSensors

We fixed an issue that caused the environment variable AWS_EC2_METADATA_DISABLED to be leaked into the environment of other sensors. For example, it did not work in cases when you had PRTG installed on an AWS environment and ran a script with a Python Script sensor that pulled credentials from an API although the role on AWS allowed PRTG to authenticate with an AWS SDK. The environmental variable was set to AWS_EC2_METADATA_DISABLED=TRUE in this case.

AWS RDS v2 sensorSensors

Your AWS RDS v2 sensors now display the correct values for the channel Database Connections again. The sensors displayed a wrong amount of connections in the mentioned channel with PRTG stable version 23.4.90.1299 since the sensors pulled the metric for 'SUM' and not 'AVG' (average) for Database Connections.

Veeam Backup Job Status Advanced sensorSensors

Your Veeam Backup Job Status Advanced Sensor is now able to display the correct value for the channel Job Scheduled when the scheduled job has been disabled. The channel Job Scheduled will now display the value No where previously the channel would have displayed the value Yes.

For more information please see our Knowledge Base article:https://kb.paessler.com/en/topic/89136 .

Device treeWeb UI

We fixed an issue that occurred when you renamed a device or group via context menu in the device tree that contained Credentials for Microsoft 365. The error message was The validation of the data you entered has failed and settings could not be saved when you tried to rename the device or group with right click on edit and rename. The issue also occurred when you tried to edit the access rights in the device tree in these cases.

Historic Data TooltipWeb UI

We fixed an issue where a second tooltip icon with tooltip text was displayed in the section Percentile Handling in the Historic Data Tab of a sensor. You could observe this behavior when you selected the radio button for Show Percentiles. The second tooltip would be displayed for Percentile Averaging Interval.

Note

Note

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Stable 24.1.92.1554

  • sha256_exe 4FBB44524659CBB03EB84B4A032B81B5042EA756C0CBC8581E77EBB278D758B8
  • sha256_zip 2C7B719939CCB1106AEE5B6C5715DC4ED80BE5E07A077FF076A5CC6D1EE7F08C
Lab

Lab

Multi-Platform Probe 0.19.0 releaseMulti-Platform Probe

The Multi-Platform Probe enables you to deploy probes on platforms not supported by the Remote Probe, including various Linux distributions and ARM hardware. In this latest release, we provide TLS support, ensuring a secure and encrypted connection to the NATS server. Additionally, we've included a user-friendly setup wizard for the NATS server, streamlining the installation and configuration process.

For more information about the Multi-Platform Probe please see our Knowledge Base article: What is the Multi-Platform Probe and how can I use it?

For detailed release notes please see our Knowledge Base article: What are the release notes for the Multi-Platform Probe?

Redfish Virtual Disk SensorSensors

The Redfish Virtual Disk sensor (BETA) is now able to handle disks that have one of the following states: Enabled, StandbySpare, InTest, Starting, Quiesced, Updating and Qualified. Previously, the sensor could handle only the state Enabled and would display the status offline for all other states.

Script v2 sensorSensors

We improved the security for the usage of Python scripts with the Script v2 sensor. All PYTHON* environment variables that might be set, like PYTHONPATH or PYTHONHOME, will be ignored when you execute scripts with the Script v2 sensor by using the parameter -E. This parameter prevents that a different e.g. PYTHONPATH is set and that Python scripts with potential security issues are run in the Python script directory.

SNMP Uptime v2Sensors

We fixed an issue for the SNMP Uptime v2 (BETA) sensor that displayed wrong values in the Live Data section of the sensor in the System Uptime channel. The issue occurred when you added the sensor to your PRTG local probe, however, it displayed the correct values when you have added it to your Multi-Platform Probe.

APIPRTG API v2
  • We fixed an issue where only one device template was returned in the settings even if there were multiple device templates for auto-discovery assigned to a device when you executed a GET request with /api/v2/experimental/devices/{id}/settings. This issue also affected the former APIv1 via /api/getobjectproperty.htm.
  • We fixed an issue that occurred when you sent a PATCH request to /devices/{id} endpoint in order to set the IPv4 host of a device. If you sent a GET request to /devices/{id} in order to check if basic.host is set to 127.0.0.1, you would notice that the host option was not set correctly. The issue happened when you created a device in the classic web interface in PRTG before with the IPv6 Hostname set without the IPv4 or a IPv4 Hostname given.
  • We made several changes for the experimental endpoint. We added the sortIndex field and sections and settings are not sorted anymore by the appserver. Default values like false for boolean or empty strings are omitted in the response.
  • Fields for read only users are now masked in the endpoints /devices/{id}/settings and /devices/{id}, for example the Credentials for Windows systems. In the previous PRTG version, those setting fields were not masked when you logged in with a read only user to the appserver and executed a GET request on a device with all settings included.
  • We fixed an issue where the parent tag of a device was not returned when you executed a GET request for the api/v2/devices endpoint. For example, if you added a tag to a specific group to which the device was added and requested the device details via endpoint afterwards, the parent tag for that device was not returned in the response.
  • We fixed an issue for the Create Device endpoint /api/v2/schemas/device?purpose=create&parent=1 that resulted in 404 NOT FOUND error although the API call was on a valid schema.
  • You can now update the inherited value for Credentials for Windows Systems under device Settings with an according PATCH request for the devices/{id} endpoint.
  • We fixed an issue where executing a GET request resulted in a not found error message when you used a newly created API key that you created before in the PRTG classic web interface. When you executed a GET request, for example, via /devices/{id} endpoint and authorized with a newly created API key first, the response would be not found on the first try. The second execution of the request would then be successful.
DevicesPRTG API v2
  • You can now create a device under a group or local probe via API v2. You can create a device by sending the according POST request on the endpoint experimental/groups/{id}/device in the Swagger UI. The device will be created on group level. For a device on probe level you need to use the endpoint experimental/probes/{id}/device.
  • Read-only users are now able to see information of the Credentials for Windows Systems settings of a device via the /devices/{id} endpoint. The available information is if the Inherit From toggle is activated or not and where the data is inherited from.
PRTG application serverPRTG API v2
  • We fixed an issue for the PRTG application server that in certain cases reported a 503 License Invalid error when you performed a GET request, e.g. GET /api/v2/devices with an according API key. The issue occurred when the PRTG application server was not connected to the PRTG core server.
  • We fixed an issue where the PRTG application server stopped working in certain cases. You could observe that the PRTG application server created a panic.log with the following error message panic: runtime error: invalid memory address or nil pointer dereference in these cases.
SecurityPRTG API v2

We fixed an issue where it was possible to escalate privileges for API-Keys.

Web interfaceNew UI
  • Automatic Logout: You will now be logged out automatically after a certain period of time in the new UI when you have activated the setting for Automatic Logout in the classic web interface. In the previous PRTG version you received an unknown error for the automatic logout process in the new UI and also the Stay logged in button did not work. You will now also receive a proper message on the login page when you were logged out automatically: You have been logged out due to inactivity.
  • Color mode: We fixed an issue where the Color Mode (Light or Dark mode) selected by a user under My Account was not applied when the user logged in to PRTG.
  • Delete device: You will now see a proper dialogue displayed when you delete a device via context menu. We improved the text to The object including all subobjects will be deleted. There is no way to undo this operation. The dialogue also displays the subobjects that will be deleted with that action.
  • Device icon: You can now change the device icon for your device in the settings for Additional Device Information. A selection of device icons opens when you click on Select Device Icon.
  • Page refresh: You can now manually reload a page within PRTG with the refresh button in the footer. The refresh timer will then start again from the beginning. You can also pause and resume the page refresh with the button in the footer.
  • Monitoring: We added an alternative Sunburst view to display and navigate monitoring objects on the left side of the split screen. You can change the display of your monitored objects in the View Settings and switch now between Tree and Sunburst view.
  • Split view: We improved the horizontal space in the split view to use space more effectively for subpages with narrow content (Device List, Info, Settings, Graphs).
  • User rights: Read-only users are now able to see the Credentials for Windows Systems in the device settings. You will see the information in the Inherit From toggle where the credentials are inherited from when you are logged in as a read-only user. The credentials for Domain or Computer Name, User Name and Password are masked.
  • We fixed an issue where redirects from the classic web interface led to application errors because the wrong endpoint was called when you clicked on the Open New UI button in certain cases.
  • You can now manage the inheritance feature toggle on the device Settings tab under Credentials for Windows Systems. When the inheritance toggle is enabled, the active values of the inheritance source are displayed and otherwise, when disabled, the active values of the device are shown. Please note that it is not possible to change the field values yet at the current implementation status.
Mobile viewNew UI

We introduced a new header for PRTG in mobile view where the menu is positioned on the top left side. The parent breadcrumb will be displayed on the top right side. The main page title Home was removed.

1
...
34567

Products

  • Paessler PRTG
    Paessler PRTGMonitor your whole IT infrastructure
    • PRTG Network Monitor
    • PRTG Enterprise Monitor
    • PRTG Hosted Monitor
    • PRTG extensions
      Extensions for Paessler PRTGExtend your monitoring to a new level
  • Icon Features
    FeaturesExplore all monitoring features

Monitoring with PRTG

  • Network monitoring
  • Bandwidth monitoring
  • SNMP monitoring
  • Network mapping
  • Wi-Fi monitoring
  • Server monitoring
  • Network traffic analyzer
  • NetFlow monitoring
  • Syslog server

Useful Links

  • PRTG Manual
  • Knowledge Base
  • Customer Success Stories
  • About Paessler
  • Subscribe to newsletter
  • PRTG Support
  • PRTG Consulting
  • PRTG Feedback & Roadmap

Contact

Paessler GmbH
Thurn-und-Taxis-Str. 14, 
90411 Nuremberg 
Germany

[email protected]

+49 911 93775-0

  • Contact us
©2026 Paessler GmbHTerms & ConditionsPrivacy PolicyImprintTrust CenterDownload & InstallSitemap
Home Home Home