We fixed an issue with PRTG version 24.2.94.1400 where the Probe update to this PRTG version failed and therefore the Probe service(s) did not start in some cases. PRTG would report an error message like PRTG probe service could not be started: The service did not respond to the start or control request in a timely fashion or Windows could not start the PRTG Probe Service service on Local Computer Error 1053: The Service did not respond to the start or could request in a timely fashion when you were affected by this issue. In some rare cases also the Core service was affected when you updated to PRTG stable version 24.2.94.1400. The issue occurred because Windows tried to load the certificate cache what took too long for the Probes during startup and caused a timeout. This issue also affected new installations of PRTG.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Stable 24.2.94.1424
A new PRTG release is available in the stable channel!
Paessler PRTG 24.2.94 has been released in the stable channel! This update brings enhancements for Single Sign-on, new settings for multi-platform probe connections, important security improvements, and updates for the German and Spanish language files. Furthermore, the multi-platform probe is now available as a stable version.
Read the complete blog post hereITOps Board version 3.15.1 comes with Notification improvements. Specifically, if you have configured notifications when an alert is raised for a board or business service, you now receive a notification when the alert is resolved. Additionally, the notifications delivered by email are updated to include more detailed information about the change to the related board or business service.
This release consolidates the location of user access settings, to improve the workflow of the interface. In this release, the settings are consolidated on a new Authorization tab: Roles, Scope Components by Boards and Services, Saved Search Visibility. This version covers also fixed issues. For more information please refer to the release notes provided with the new version.
We are happy to announce that the multi-platform probe has entered its stable status after extensive feedback and testing and it's now recommended for productive use. While the classic remote probe is used on Windows systems, the multi-platform probe allows you to deploy probes on various non-Windows systems. These include Debian, Ubuntu, Redhat, and ARM-based systems.
Key Features:
Upgrade your monitoring capabilities with the multi-platform probe!
For more information about the multi-platform probe and how to use it, please see Multi-Platform Probe for PRTG manual.
For detailed release notes about this release, see our Knowledge Base article: What are the release notes for the Multi-Platform Probe?.
We added the NATS Connection Security toggle in the Multi-Platform Probe Connection Settings to explicitly set the security schema used.
The configuration for connecting the PRTG core server to a NATS server has changed. The schema is now an explicit toggle instead of encoded into the NATS URL. The NATS URL setting was changed to NATS Server Host, which is made up of the hostname and port of the NATS Server. After this update, the NATS Server Host setting will be reset to the default localhost:23561 value and users will need to reconfigure their NATS server.
Important for PRTG Hosted Monitor: This setting is not visible for PRTG Hosted Monitor instances. Customers will be informed separately, as soon as the multi-platform probe can be used with PRTG Hosted Monitor.
Credentials like passwords in the PRTG configuration file are now masked when you use the option Include configuration file (contains passwords) for Send Logs to Paessler in the PRTG Administration Tool in order to send a support bundle. When you have a larger configuration file, e.g. 355 MB and run the PRTG Administration Tool as a 32 bit version, you will receive a message that PRTG was not able to hide encrypted passwords in the configuration file. The same behavior applies when you want to send a support bundle with a broken configuration file. You will then be asked if you still want to include the configuration file containing passwords or not.
Please note that currently is not possible to start the Administration Tool for a Remote Probe running on a 64-bit operating system. As a workaround go to the Program Files (x86) folder, open the PRTG Network Monitor folder, and run the 32-bit version of the Administration tool. We will deliver a fix for this issue in the upcoming PRTG versions.
The behavior of the Environment setting was changed for the EXE/Script and EXE/Script Advanced sensors to prevent remote code execution for Batch (.bat) scripts. Thanks to IT Matters Most GmbH who made us aware of that vulnerability and which can be tracked under CVE-2024-28055, with severity 7.2 AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H. Please note that this change might cause your running custom scripts to fail as it is no longer possible to use the environment variables placeholders in the Parameters setting for Batch (.bat) scripts anymore.
You will now see a log entry in the History tab of a device when you have enabled or disabled the inheritance of an object. For example, if you enable the Inherit From feature toggle for Credentials for Windows Systems, it will be logged as Credentials for Windows Systems: Inherited in the History tab of the device.
We improved the Single Sign-on handling for PRTG user integration in Microsoft Azure AD to support the Microsoft Graph API for paging when a user is assigned to more than 100 groups. Previously, the issue occurred in certain cases that a user with Microsoft Azure AD integration could not log in to PRTG via Single Sign-on when he was assigned to more than 100 groups. Due to limitations in the Access Token concerning the group memberships we need to switch to Microsoft Graph API for paging what was not yet supported by PRTG. The user would then receive the message that the login has failed. In the Core.log you could also find this error message for the user login: is no member of SSO groups allowed by PRTG.
Various other minor fixes and improvements, updated user manual.
We updated the German and Spanish language files.
We updated the Spanish language files for certain selected sensor types.
We changed Bytes (File) to Bytes (Disk) in the Channel Unit Configuration of the VMware Datastore (SOAP) sensor to better match the size of datastores. Please note that this change will come into effect only when you add this sensor type as new and does not affect any existing sensors.
We fixed an issue for the Find Duplicates feature on /api/findduplicates.htm. Previously, if you selected the option Find Duplicates from the device Context menu the result you would have received was empty.
We fixed an issue for the HTTP transaction sensor that could not access a target URL anymore in certain cases and reported the error message String not found in the previous PRTG version, or when you changed to Compatibility engine in the sensor settings the error message was Object reference not set to an instance of an object.
We fixed an issue that could cause a higher memory consumption especially on the Multi-Platform Probe when you ran MQTT sensors and OPC UA sensors on your system. We therefore also updated our MQTT library to version 1.3.13 what patches several issues.
Your Microsoft Azure SQL Database sensor will now report an according sensor message when the monitored single database or elastic pool is in a different state then Online or Ready. Previously, the sensor reported an error message The queried field "average,count,maximum,minimum,total" is empty. when, for example, the queried database was in status Paused.
We fixed an issue for the Oracle SQL v2 sensor that reported an error The type initializer for OracleInternal.Common.ProviderConfig threw an exception when Oracle Data Access Components (ODAC) was installed on the system where also the sensor was added, e.g. on a remote probe. The sensor then went into an error state in this case because one of the Oracle assembly references did not match.
The QoS (Quality of Service) One Way sensor now no longer displays any IP address in the Quality of Service Measurement section for Target Probe when you are about to create this sensor type. Previously, the sensor displayed 127.0.0.1 for the local probe what did not reflect the actual probe ID being used.
The Result of Sensor.txt file will now be updated again when you have activated the Store result option for Debug Options in the sensor Settings. Updating the Result of Sensor.txt file did not work anymore in the previous PRTG versions for certain sensor types. This issue affected sensor types like Traceroute Hop Count sensor, Windows Print Queue sensor and Active Directory Replication Errors sensor, for example.
We fixed an issue where in certain cases the message reported by the sensor suddenly displayed only OK after some time. In these cases the message of the sensor was reverted from the original to OK when the message sent from Probe to Core contained an empty string for some reason. The issue occurred for sensor types like WMI Custom String sensor, SNMP Custom String sensor and REST Custom v2 sensor.
We fixed an issue that occurred for certain sensor types, like the SNMP Custom v2 sensor, where an additional text overlapping the help box was displayed in the section for Schedules, Dependencies and Maintenance Window. Additionally the default dates for Maintenance Begins and Maintenance Ends were not displayed correctly.
We fixed an issue for the SNMP HPE ProLiant Physical Disk Sensor that reported an error Disk: Required field, not defined when you added multiple disks where at least one disk was defective, e.g. did not report serial number and model values. As a result, the sensor could not be created and additionally the PRTG configuration file could also no longer be saved. You will now be able to save your PRTG configuration file again even if your SNMP HPE ProLiant Physical Disk sensor includes a defective disk.
We fixed an issue for the SNMP Memory sensor that reported the error message (value)' is not a valid integer value in certain cases. The issue occurred because certain devices falsely returned counter values instead of integer values for the storage size in the OID 'hrStorageSize' (1.3.6.1.2.1.25.2.3.1.5) what the sensor then could not process correctly.
We fixed an issue for the Windows Print Queue sensor that did not report the correct sensor message when monitored printers were offline or paused. The sensor wrongly reported the status message up in these cases.
We fixed an issue where in certain cases API calls to PRTG failed with the error Unauthorized although the API token was valid. For example, when you use the API endpoint /api/table.json to reach PRTG with a valid created API key, it could happen that the call resulted in an Unauthorized message.
You will now be able to save the settings for all your selected sensors when you use the multi-edit function. This did not work properly before in the previous PRTG versions in certain cases. Saving the value Maximum (Mbit/s) for the channel Traffic Total when you have selected several SNMP Traffic sensors would only work for the first sensor in the list, not for all sensors that you selected via multi-edit.
We fixed an issue for sms notifications that were cut off in the text when you used certain special characters, like for example ampersand &.
We fixed an issue for notification triggers, that is Speed, Volume and Threshold trigger where added values in the PRTG web UI would not be saved correctly in certain cases. It could happen that after you have entered for example a valid value for bit/second in the Speed trigger under Notification Triggers, that the value was saved afterwards with 0 or even an invalid float value. We also fixed this issue for the PRTG App for desktop.
We fixed an issue where not all probe Settings were displayed in the previous PRTG versions when you installed a new remote probe on your system. When you have added a remote probe successfully and opened the probe Settings tab you could see that, for example, the Credentials for Cisco Meraki were missing.
You can now acknowledge alarms with your read-only user in the PRTG App for Desktop when you have set the according rights for that user in the PRTG web interface before. Previously, when you have created a read-only user in PRTG and afterwards added additional rights Allow user to acknowledge alarms to that user, the settings would not automatically be updated when the user was logged in to the PRTG App for Desktop. As a workaround, you had to restart the Core server or the user had to log in to PRTG App for Desktop again.
We fixed an issue where the execution of an auto-discovery with device template on the PRTG App for Desktop produced an access denied message in the CoreWebServer.log.
With this version we discontinue the below already deprecated sensors:
If you run any of these sensor types they will show an error message This sensor type was removed from PRTG. For more information, see https://kb.paessler.com/en/topic/68227. (code:PE258), when you update your PRTG installations to version 24.1.94. You can pause existing sensors afterwards but you will not be able to deploy them anymore.
For further information about sensor deprecation and discontinuation in general as well as successor sensors and sensor alternatives please see our Knowledge Base articles: What do deprecation and discontinuation in the context of sensors mean? and What sensors are deprecated and what are their successors or alternatives?
Currently it is not possible to install or uninstall the PRTG application server via button Install Service or Uninstall Service in the PRTG Administration Tool. The PRTG Administration Tool will execute a Core server restart but the PRTG application server will not be installed or uninstalled afterwards. To install the PRTG application server and make use of the new UI and APIv2, please see our Knowledge Base article: I want to use the new UI and API v2. What do I need to know?
You will receive an error when you click on the button Stop Service or Start Service (ignore changed settings) for the Core and Probe service in the PRTG Administration Tool when you run it as a 64bit version on your system. The PRTG Administration Tool will then report the following: One or more required program components of PRTG (PRTG Server.exe, PRTG Probe.exe) could not be found! Please re-run the installation program. This issues does not occur when you run the PRTG Administration Tool in a 32bit mode. We will deliver a fix for this issue with the upcoming PRTG versions.
Solved with PRTG Stable version 24.2.96.1315
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Stable 24.2.94.1400
You can now configure and manage your Credentials for Windows Systems in the device settings in the new UI and also via API v2. This enables you to use sensors on your device which require windows authentication, like WMI sensors. The available fields are Domain or Computer Name, User Name and Password. You can also see and manage the Inherit From toggle and enable or disable it. The windows credentials will also be visible in the new UI when you set them via APIv2 PATCH request on the endpoint /api/v2/devices/{id}. Additionally you are now able to edit the following device settings in the new UI and APIv2: Credentials for VMware/XenServer, Credentials for AWS, Credentials for Script Sensors, Advanced Network Analysis.
We improved the navigation in the mobile view for the new UI. When you click on the menu icon it opens a drawer from the left hand side. The drawer remains open during navigation and you can close it with the x button. Additionally, when you select home in the side bar, you will see links to the sections Welcome and Quickstart.
We fixed an issue for the PRTG application server that ran into panic mode when you ran a mini probe on your PRTG installation, for example a Python Mini Probe or a PRTG Mobile Probe for Android. The created panic log would display the error panic: runtime error: invalid memory address or nil pointer dereference in these cases.
PRTG release 24.1.92 is available in the stable release channel!
The latest version of Paessler PRTG, 24.1.92, is now available through the stable release channel! This version comes with several new sensor types that are now fully supported (like the Ping v2 sensor, HTTP v2 sensor and SNMP Uptime v2 sensor), an update for OpenSSL, and several other improvements throughout Paessler PRTG.
Read the complete blog post hereThe Cisco Meraki License sensor monitors Meraki licenses of an organization and the Cisco Meraki Network Health sensor monitors the health of Cisco Meraki network devices. Both sensor types use the Cisco Meraki Dashboard API. We released these sensor types as experimental sensors with PRTG version 22.1.74.1869.
This sensor monitors VPN connections of your Fortinet FortiGate firewall. The sensor shows the number of connected SSL clients, as well as the number of both up and down IPsec tunnels. We released this sensor type as experimental sensor with PRTG version 22.1.74.1869.
This sensor allows you to send a HTTP request (HEAD, GET or POST) and use placeholders, similar to the REST Custom v2 sensor. We released this sensor type as experimental sensor with PRTG version 22.4.81.1532.
The Local Folder sensor monitors a local folder on a probe system. We released this sensor type as experimental sensor with PRTG version 21.3.70.1629.
The Network Share sensor monitor a Server Message Block (SMB) or Common Internet File System (CIFS) network share. We released this sensor type as experimental sensor with PRTG version 21.4.73.1656.
The Ping v2 sensor comes with a new setting Inverted Error Status different to its predecessor. If you select Enable for this new setting, the sensor shows a Down status if the target device is reachable. The Ping v2 sensor supports IPv6. We released this sensor type as experimental sensor with PRTG version 22.4.81.1532.
his sensor monitors the virtual disks of your Redfish capable servers and shows capacity and status. We introduced this sensor type as experimental sensor with PRTG version 21.3.71.1416.
This sensor type comes with the same basic settings as the already existing SNMP System Uptime sensor including the additional Data Source setting under the section SNMP Uptime Specific, where you can select the object identifier (OID) the sensor gets its uptime from. The Data source is also depicted in the sensor status. We released this sensor type as experimental sensor with PRTG version 23.2.84.1566.
This sensor monitors the status of processes within an Orchestra scenario. Please note that this sensor requires a Soffico license and as of Orchestra 4.8.2.5. We released this sensor type as experimental sensor with PRTG version 23.4.90.1299.
We improved the creation of API keys via API call requests to match the given access rights. Previously, it was possible to create an API key for a read/write user with the parameter accesslevel_new=full via GET request, although the user only has write access at the most according to the API key access rights settings. The Access Level for the created API key then wrongly displayed full access.
We fixed an issue where an authenticated attacker could craft a specific request against the editlicense.htm endpoint and change the license of PRTG partially affecting the availability of PRTG. The severity is 4.3-Medium and calculated as CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L.
We fixed a reflected XSS vulnerability which allowed JavaScript injection. The severity is 6.1-Medium and calculated as CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N.
We added the option for SNMP Trap notifications to include the sensor ID that triggers the notification in the trap message. If you select the option Include sensor ID in the Send SNMP Trap notification template, PRTG will send it on the OID 1.3.6.1.4.1.32446.1.1.5. Previously, parsing the sent trap messages was not possible for certain third party systems due to the missing option.
To ensure secure communication furthermore we updated to the OpenSSL version 1.1.1w.
Various other minor fixes and improvements, updated user manual.
We updated the German and Spanish language files.
We updated the German and Spanish language files for certain selected sensor types.
You can now send support bundles with the Contact Support option when you have configured a proxy server in the PRTG Core & Probes settings.
Important: The issue still appears in the Paessler PRTG app for desktop.
You will now receive a proper error message Error (Bad Request) again when you enter an invalid (old) password under My Account in your Account Settings. In the previous PRTG version there was a log entry in the Core webserver log Error: The validation of the data you entered has failed, but no corresponding error message in the web interface. The issue occurred when you selected the option Specify a new password and entered an invalid Old password.
We fixed an issue that caused the inheritance to be disabled for all settings of a device if you changed settings in the Device List before. The issue occurred when you selected several devices in the Device List via Settings option in the multi-edit and saved the changes. The settings of the devices where you made the changes for were set to disabled in the Inherit From toggle.
We fixed an issue for historic data reports that displayed not all or additional hours in the Date Time table when the user has set a different time zone under My Account in the PRTG Web Interface. For example, when your time zone in your account was set to (UTC -6:00) and you ran a historic data report for 12 hours, the report would in this case substract the hours in the Date Time table from the UTC time zone set under your account..
We fixed an issue for an unauthorized Ajax error that occurred in certain cases in the CoreWebServer.log instead of displaying the correct error message Your user account is not allowed to access this information. The issue happened when you were logged in with a user account whose assigned user group has write permissions on a library but who is not allowed to access user information when you clicked on the Security Context link for the user to see the User Account Settings.
We fixed an issue for lookup files where changes were not reflected in the web interface when you changed values in lookup files after OID library creation. Changes to lookup values were only displayed after a complete PRTG core server restart. The issue affected for example the SNMP Library sensor, but also other sensors that come with value lookups and appeared only for the first modification in the lookup file.
We fixed an issue where PRTG stored the data for the Installation Path in the same folder as for the Data Path when you selected to run the PRTG installer in the Custom mode for fresh installations since PRTG version 23.3.88. The issue happened when you changed the Data Path directory in the path field directly.
Your remote probes that you have deleted from the device tree will no longer appear on your PRTG Status Page under the Probes and Database Objects sections, or in the information returned when you execute a query on PRTG Health System Information via an API call /api/health.json?. In the previous PRTG version, a deleted remote probe would still be displayed on the mentioned sections with the status disconnected.
You can now sent reports by email again for scheduled reports in the Report Schedule setting. Previously, when the report schedule sent out an email to a configured email address or PRTG user group you would receive an access violation in the Core.log and in certain cases also the message Error sending Report Email. The issue occurred if you selected a schedule for a report in the Report Schedule setting with Target Email Address and/or Email to User Group.
We fixed an issue where you could not save your Scanning Intervals in certain cases when you used a regular interval and a UTC interval with the same unit. For example, if you entered 4h and @UTC 4:00 at the same time in the Available Intervals section you would receive a validation error upon saving your changes.
We fixed an issue for certain sensors on addsensor.htm that could be added although the device or group to which you want to add these sensor types did not have corresponding credentials. When you tried to add an AWS sensor, for example, to a device without Credentials for AWS, you received an error message Sorry, the scan for available monitoring items has failed! The AWS sensors will now be displayed as inactive on addsensor.htm with a hint that valid credentials are needed when you try to add them to a device without Credentials for AWS. This issue was also fixed for the Local Folder sensor (BETA) and the Network Share sensor (BETA).
We fixed an issue that caused the environment variable AWS_EC2_METADATA_DISABLED to be leaked into the environment of other sensors. For example, it did not work in cases when you had PRTG installed on an AWS environment and ran a script with a Python Script sensor that pulled credentials from an API although the role on AWS allowed PRTG to authenticate with an AWS SDK. The environmental variable was set to AWS_EC2_METADATA_DISABLED=TRUE in this case.
Your AWS RDS v2 sensors now display the correct values for the channel Database Connections again. The sensors displayed a wrong amount of connections in the mentioned channel with PRTG stable version 23.4.90.1299 since the sensors pulled the metric for 'SUM' and not 'AVG' (average) for Database Connections.
Your Veeam Backup Job Status Advanced Sensor is now able to display the correct value for the channel Job Scheduled when the scheduled job has been disabled. The channel Job Scheduled will now display the value No where previously the channel would have displayed the value Yes.
For more information please see our Knowledge Base article:https://kb.paessler.com/en/topic/89136 .
We fixed an issue that occurred when you renamed a device or group via context menu in the device tree that contained Credentials for Microsoft 365. The error message was The validation of the data you entered has failed and settings could not be saved when you tried to rename the device or group with right click on edit and rename. The issue also occurred when you tried to edit the access rights in the device tree in these cases.
We fixed an issue where a second tooltip icon with tooltip text was displayed in the section Percentile Handling in the Historic Data Tab of a sensor. You could observe this behavior when you selected the radio button for Show Percentiles. The second tooltip would be displayed for Percentile Averaging Interval.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Stable 24.1.92.1554
The Multi-Platform Probe enables you to deploy probes on platforms not supported by the Remote Probe, including various Linux distributions and ARM hardware.
In this latest release, we provide TLS support, ensuring a secure and encrypted connection to the NATS server. Additionally, we've included a user-friendly setup wizard for the NATS server, streamlining the installation and configuration process.
For more information about the Multi-Platform Probe please see our Knowledge Base article: What is the Multi-Platform Probe and how can I use it?
For detailed release notes please see our Knowledge Base article: What are the release notes for the Multi-Platform Probe?
The Redfish Virtual Disk sensor (BETA) is now able to handle disks that have one of the following states: Enabled, StandbySpare, InTest, Starting, Quiesced, Updating and Qualified. Previously, the sensor could handle only the state Enabled and would display the status offline for all other states.
We improved the security for the usage of Python scripts with the Script v2 sensor. All PYTHON* environment variables that might be set, like PYTHONPATH or PYTHONHOME, will be ignored when you execute scripts with the Script v2 sensor by using the parameter -E. This parameter prevents that a different e.g. PYTHONPATH is set and that Python scripts with potential security issues are run in the Python script directory.
We fixed an issue for the SNMP Uptime v2 (BETA) sensor that displayed wrong values in the Live Data section of the sensor in the System Uptime channel. The issue occurred when you added the sensor to your PRTG local probe, however, it displayed the correct values when you have added it to your Multi-Platform Probe.
We fixed an issue where it was possible to escalate privileges for API-Keys.
We introduced a new header for PRTG in mobile view where the menu is positioned on the top left side. The parent breadcrumb will be displayed on the top right side. The main page title Home was removed.
CVE-2023-51630 - ZDI-CAN-21182: An XSS vulnerability was identified through the htmclass parameter in the error.htm in PRTG 23.4.90.1299 and earlier versions where an attacker could bypass the authentication by creating a malicious link and luring a PRTG user with an active session to click it. The severity of this vulnerability is high and received a score of 8.8, (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
For further information, please refer to ZDI-24-073 and CVE-2023-51630
We would like to thank n1nj4sec for working with Trend Micro Zero Day Initiative and responsibly reporting this vulnerability.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Stable 24.1.90.1306
PRTG release 23.4.90 is available in the stable channel
The most recent version of Paessler PRTG, 23.4.90, is now accessible through the stable release channel!
Read the complete blog post hereFilters page
Data Collection page
Profile Activity page
Dashboard page
Small bug fixes and changes
Can now be defined by selecting filters, SLAs, and/or individual sensors
New setting added that can be used to enable debug logging
ITOps Board version 3.13 comes with accessibility enhancements. In this release, the Explorer tab has been updated for accessibility and now includes text labels to indicate the health state of each component. Additionally this release introduces the use of icons to indicate the health state of components and alerts.
It also covers fixed issues. For more information please refer to the release notes provided with the new version.
Important Notice: Upgrade Process. The ITOps Board installer supports an in-place upgrade. If you made manual changes to the web.config file, those changes are not preserved during an in-place upgrade. Any manual changes to the web.config file are saved in a file with a name that uses the following format: Web-YYYY-MM-DD.config. Before you begin an upgrade, save a copy of this file. It is recommended that you use the file as reference to make changes to the new web.config file, which will overwrite the previous file during the upgrade process. Do not overwrite the new web.config file with the old file.
This release of ITOps Board requires Elasticsearch version 7.17.6.
The reset token in the link for setting a new password is now masked in the CoreWebServer.log. It was logged in a readable format before when you clicked on the link for setting a new password with the forgot password option.
Your Exchange Database DAG (PowerShell) sensor now recognizes newer versions of Exchange Server (>2019) and can distinguish between versions i.e 2010, 2013, 2016 and 2019. Previously the sensor recognized the Exchange Server 2019 version as an older version and tried to use this information, resulting in a Warning status for the Active Copy Channel with the message Could Not Read Activation Preference.
We updated our database connectors for certain EXE sensor types, e.g. Oracle SQL v2 sensor, MySQL v2 sensor and PostgreSQL sensor. Previously, the connection to the corresponding databases failed due to required encryption ciphers that did not match.
Your OPC UA Custom sensor now supports more data types, that means enums and single values from array-valued variables. Previously, the sensor supported only string, Boolean, and numeric variables.
We improved the following sensor types to support the Proxy Settings in the device settings so they are able to use a HTTP proxy server when you have set up one in the device settings:
You can now create device templates that include the sensor types Soffico Orchestra Channel Health sensor and Soffico Orchestra Scenario sensor (BETA). This enables you to add these sensors via auto-discovery.
Various other minor fixes and improvements.
We have updated the manual to provide recommendations on how to handle PRTG configuration files in a secure manner, please see the updated manual sections Files and Subfolders in the PRTG Data Directory and Handling Configuration Files.
We updated the Chinese, French, German, Japanese, Portuguese, Russian and Spanish language files.
We updated the Chinese, German, French, Japanese, Portuguese, Russian and Dutch language files for certain selected sensor types.
With this PRTG version the MySQL v2 sensor does not support the integrated Windows authentication for MySQL anymore due to a license change in the database connector. The sensor will request the Windows password and username instead.
We renamed the sensor types Windows IIS 6.0 SMTP Received sensor to Windows SMTP Service Received sensor and Windows IIS 6.0 SMTP Sent sensor to Windows SMTP Service Sent sensor to meet the technical requirements.
We fixed an issue that affected the creation of Reports, Notification Templates and Schedules when you were logged in as a user with read/write access. When you were logged in as a read/write user, you would get an Unauthorized ajax error when you tried to create a Report, Notification Template or Schedule. However, the creation was successful in the background and visible to PRTG users with administrative rights afterwards.
We fixed an issue where the created API key for an active directory user was still valid for a certain period of time even though the active directory user was deleted. Previously, when you created a new user in your active directory and connected it with your PRTG installation and also created an API key for this user, the API key would still be valid for a while even the login credentials were not when you deleted the user afterwards. The API key is now promptly invalid like the credentials when you delete the user from your active directory.
Public map rotation is now working again as expected. Previously, if you used the public map rotation feature without login credentials required, only the first map would be displayed or the other maps would be displayed as blank pages instead.
You can now create Historic Data Reports in the Historic Data tab for sensors as .csv file format again with the setting for show percentiles activated. Previously, the historic data report would run into an Ajax Error: timeout when you selected the format .csv file and additionally selected the radio button for show percentiles.
We fixed an issue for certain selected sensor types that caused the previously set scan interval to be ignored and always run for the default value of 60 seconds. In addition, the interval information was not added to the sensor log in cases where the
We implemented various improvements for the AWS v2 sensors:
We fixed an issue for certain EXE sensor types, such as the ADO SQL v2 sensor, where the parsing for arguments failed when the Connection String in the Database Specific setting contained a linebreak. The sensor reported a down status with the message Invalid Authorization Specification in these cases.
We fixed an issue for the MySQL v2 sensor where the executed SQLV2.exe client tool reported an error with the message Parameter -sslmode is missing. With PRTG version 21.2.68.1492 we introduced a dedicated setting for the SSL mode; however, this setting was initially only implemented for the Command Line Interface. The options you could choose are the same as the values of the MySQL sslmode parameter.
We fixed an issue for certain Flow sensors, like the NetFlow v9 sensor or IPFIX sensor, that led to access violations in certain cases when the data flow contained fields with variable length.
We fixed an issue for the OPC UA Server Status sensor that reported the following error message in certain cases: The sensor could not connect to the OPC UA server (BadConnectionClosed). The issue occurred because the endpoint selection changed with an update of the library open62541 that is used by OPC UA.
We fixed an issue for the HPE ProLiant Memory Controller sensor that in some cases could not be created on a HPE ProLiant Gen10 server when the device type was 1 (other) in the given OIDs. An error with the message The sensor could not find any matching data on the monitored device occurred in these cases during sensor creation.
We fixed an issue for the SMTP sensors where the HELO ident that you configured in the Authentication setting of the sensor was ignored and instead e.g. the default hostname of the probe was used. This issue affected the SMTP sensor, SMTP&POP3 Round Trip sensor and the SMTP&IMAP Round Trip sensor.
We fixed an issue where the footer on the PRTG web interface displayed Renew Maintenance when you had an active subscription license and when you were logged in with an account with administrative rights. The button Renew Maintenance appeared regardless of the maintenance days you had left. The footer now displays correctly the Contact Support button.
With this PRTG version we introduce a solution for offline installations of Paessler PRTG Enterprise Monitor that allows you to use a special Paessler PRTG Enterprise Monitor license for an offline system. You will be contacted by your Paessler Sales representative if this change applies to you.
For more information please see our Knowledge Base article https://kb.paessler.com/en/topic/91881.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Stable 23.4.90.1299
You can now create the Script v2 sensor (BETA) when you execute the Run Auto-Discovery with Template function on a device. The sensor will be created only when you have Python installed on the probe system.
We fixed an issue for the SNMP Disk Free v2 (BETA) that displayed wrong values in certain cases when you updated to PRTG version 23.3.88.1393. The issue occurred in cases when you monitored disks with a larger volume. The sensor then reported wrong values like 0% for the percentage channel Free Space and went into error status. Additionally, the absolute values in the channel Total were displayed as negative. The issue happened because the value calculation in the sensor was exceeded by the large values and the sensor could not handle the value overflow correctly.
Your SNMP Traffic v2 sensor now includes the tag snmp in the default tags that are automatically predefined in the Basic Sensor Settings when you add the sensor.
You can try out our experimental Soffico Orchestra Scenario sensor that we introduce with this PRTG version. This sensor monitors the status of processes within an Orchestra scenario. The sensor comes with the channels Aborted Count, Downtime, Finished Count, Paused Count, Running Count and Warning Count. Please note that this sensor requires a Soffico license and as of Orchestra 4.8.2.5.
You can now add the sensor types Local Folder Sensor (BETA) and Network Share Sensor (BETA) to your device template when you select the function Create Device Template in the device tree. This enables you to create these sensors afterwards with the option Run Auto-Discovery with Template.
We added a new parameter purpose to the /schemas/{kind} endpoint that supports the values create (for POST), update (for PATCH) or read (for a GET endpoint). The endpoint returns the appropriate schema for a given purpose.
We fixed an issue for the Last Value column in the new UI that displayed 0% as difference value. The Last Value column now no longer show a difference value of '0' in the sensor channel list when the value is 0% as difference between Warning Limit and Last Value.
We fixed an issue that occurred when you deleted devices that were included in a map. Previously after you deleted devices in the new UI that were included in a publicly accessible map you would receive the warning message Monitoring might be incomplete or inaccurate due to fundamental problems in your PRTG installation! Click here for more information! when you opened the map then in the classic UI. In addition, the Core Health sensor displayed a down status with the error message Free Physical memory is below error limit of x in Free Physical Memory. The public access page for the map was also not accessible and reported the error Map Refresh Failed in these cases.