With this PRTG version, we introduce the new FTP Server File Count v2 sensor, a successor to the existing FTP Server File Count sensor, ensuring you can continue monitoring file counts on your FTP server. The sensor connects via an FTP URL, rather than separate host/port settings, and lets you configure recursive subfolder scanning, Passive or Active FTP mode, request timeout, and connection security (Explicit, Implicit, or None). This sensor type supports IPv4 and IPv6.
With this PRTG version, we introduce the new Redfish Fan Status sensor, giving you a single, consolidated view of fan health and speeds for a server via Redfish. This sensor creates the channels Overall Status, (Fan Name) Status and (Fan Name) Speed. You can now replace the SNMP HPE ProLiant System Health sensor with the Redfish sensors (Redfish System Health, Redfish Temperature, and Redfish Fan Status), fully migrating from SNMP to Redfish for HPE ProLiant servers.
With this PRTG version, we introduce the new Redfish Temperature sensor, which lets you monitor individual temperature readings from any Redfish-compliant server. The sensor creates one instance per physical temperature probe, giving you granular thermal visibility and per-sensor alerting instead of a single rollup value. This sensor supports IPv4 and IPv6.
With this PRTG version, we introduce the new SNTP v2 sensor, which monitors a Simple Network Time Protocol (SNTP/NTP) server. The sensor checks the time difference between the target NTP server and the probe's local system time, the server's response time, and its stratum level. Unlike the already existing SNTP sensor, this sensor reports the time offset at millisecond resolution instead of in whole-second steps, making small clock drifts visible so you can set alerts on them. This sensor comes with the channels Response Time, Offset, and Stratum. The sensor supports both IPv4 and IPv6 and is compatible with the Classic probe, the Multi-Platform Probe, and PRTG Hosted Monitor.
With this PRTG version, we introduce the new WMI Network Card v2 sensor, a successor to the classic Windows Network Card sensor for monitoring bandwidth usage and traffic statistics of Windows network interfaces. The sensor uses WMI to track in/out traffic, packet rates, and error/discard counters, helping you detect overloaded links, faulty interfaces, or unusual traffic patterns. The sensor runs on PRTG classic Probe and will be supported on the upcoming Multi-Platform Probe for Windows.
With this PRTG version, we introduce the new WMI Print Queue v2 sensor, a modern successor to the existing Windows Print Queue sensor, letting you monitor print queues on your Windows print server. The sensor discovers print queues and reports the number of jobs in the queue, optionally filtered by a minimum print job age so only jobs older than a defined threshold are counted. You can optionally define custom sensor states (Warning or Down) for specific printer return messages, such as Paper Jammed, Toner Out, or Offline, instead of using the default behavior of ignoring these messages. This sensor works on PRTG Classic Probe and will be supported on the upcoming Multi-Platform Probe for Windows.
With this PRTG version, we introduce the new WMI Windows Security sensor as a successor to the WMI Security Center sensor, which monitors the security status of Windows client systems via WMI by reporting on security products registered with the Windows Security Center, such as antivirus, antispyware, or firewall products. Each sensor reports Product Status as the primary channel, along with Signature Status. This sensor does not run on Windows Server systems, since the Windows Security Center is only available on client Windows versions. This sensor works on PRTG Classic Probe and will be supported on the upcoming Multi-Platform Probe for Windows.
You can now monitor available (free) system memory on Windows using the new WMI Memory v2 sensor. The sensor connects via WMI and provides free memory in bytes and as a percentage, helping you detect low-memory situations before they impact application performance or stability. This sensor will also be supported on the upcoming Multi-Platform Probe for Windows.
You can now monitor the CPU load of Windows systems using the new WMI CPU Load v2 sensor. The sensor gives you full visibility into CPU utilization, both as an overall total and broken down per logical processor core, helping you quickly spot overloaded systems and identify uneven load distribution across cores. This sensor will also be supported on the upcoming Multi-Platform Probe for Windows.
You can now monitor how long a Windows system has been running since its last reboot with the new WMI System Uptime v2 sensor. Use it to detect unexpected reboots early and verify the stability and availability of your systems over time. This sensor will also be supported on the upcoming Multi-Platform Probe for Windows.
With this PRTG version, we introduce the new WMI Pagefile v2 sensor, which monitors the overall usage of the Windows paging file on a device. The sensor shows total pagefile usage in percent, helping you detect memory pressure situations and prevent performance degradation due to excessive paging. The sensor is compatible with the Classic Probe and will be supported on the Multi-Platform Probe for Windows.
We enforced input sanitization on sensor channel names to defend against possible Cross-Site Scripting (XSS).
We improved and sanitized the displayed data in Bad Request error dialogues that occur during data validation when you entered disallowed characters or invalid data.
We performed sanitization on notification message parameters to prevent information disclosure.
We hardened PRTG against possible cross-site scripting (XSS) attacks related to output on error pages.
We improved the log message that is logged in the Log tab when you pause an object indefinitely. Previously, the log message only displayed the status pausing. The log message now also displays paused when the process is finished.
We added an explicit Certificate Validation option to HTTPS-based sensors, giving you control over how strictly certificates are checked. The following sensor groups use strict validation that is now enabled by default: Cisco Meraki, Microsoft 365, Microsoft Azure, Cloud, and Zoom. These sensors will fail if they encounter an untrusted or manipulated certificate. The other sensor groups, as follows, keep the default accept any certificate so existing behavior is unchanged: DellEMC, Fortigate, HPE 3PAR, HTTP v2, NetApp, Orchestra, PRTG Data Hub, Proxmox, REST v2, Redfish, VMware, and Veeam. Please note that on Windows, the Cloud and Zoom sensors (now using strict validation) may fail if the intermediate CA certificate is not directly installed in the certificate store. This is a known limitation and might happen especially if you are using a deep inspection firewall manipulating the SSL certificates.
The Script v2 sensor now supports PowerShell 7 (PowerShell Core) with this PRTG version, letting you run modern scripts that rely on PS 7 features or modules. The sensor now detects and runs PowerShell scripts using a secure script-wrapper environment that disables verbose event logging. Please note that the already existing EXE/Script sensors continue to support PowerShell 5.1, since compatibility with PowerShell 7 and the old sensors is not given.
Various other minor fixes and improvements, updated user manual.
We updated the German, Dutch and Spanish language files.
You will see an additional information on the PRTG Setup page for System Status: UVExplorer. This entry is intended to prepare for future releases and currently shows the statuses disabled, unknown, and n/a.
We fixed an issue where sensors that were set to Down (Acknowledged) Indefinitely lost their acknowledged status after a cache recalculation. The issue happened when you triggered a Cache recalculation manually and the acknowledged sensors reverted to Down Status after the Service Restart.
We fixed an issue that occurred in previous Preview version 26.3.123.1654, where the PRTG Core service ran into a read lock in certain cases when you set up a new Multi-Platform Probe using this PRTG Preview version. After adding the NATS Server Access Identifier in the NATS Connection Settings and restarting the Core service, you could observe the following error in the Core.log: The current Thread ran into a timeout after entering a writelock, waiting for readers to leave.
We fixed an issue for the HTTP v2 sensor that reported an error with the message The sensor could not get a response from the server. 302 (Found) in certain cases. The issue occurred in cases where connections closed by some embedded HTTP servers without sending a proper close_notify were incorrectly reported as an error, even though the response data had already been fully received.
We fixed an issue where the field for Login Header Name was visible when you used None (default) for the Authentication Method in the Credentials for REST API settings. The Login Header Name field is now only visible when you select the option Session-based authentication with Header (default).
We fixed an issue where the NetApp LUN v2 sensor treated the comment field as mandatory, causing sensor creation to fail for NetApp ASA r2 systems, where this field is not present in the LUN REST API response at all.
We fixed an issue for the SNMP Library sensor where it was possible to select the entry Select a file in the Please select a library file pop-up window during sensor creation. Creating this sensor would fail with the error message Nothing was selected, no sensors could be created when you had selected this option.
We fixed an issue for sensors that use a strict certificate validation so that system, group policy or enterprise certificates are now properly imported using the Certificate Validation settings. This fix applies for Cisco Meraki, Microsoft 365, Microsoft Azure, Cloud and Zoom sensor types.
We fixed an issue where the Processes table on the System Information tab remained empty when no SNMP credentials were configured, even though WMI was unavailable and SNMP was able to retrieve values. This issue occurred when you had configured the WSMan protocol for WMI connections before.
We fixed an issue where PRTG Desktop failed to load a device's child sensors when a Ping v2 sensor on that device was in timeout state and returned an INF value for lastvalue_raw. Previously, the API response's non-standard INF JSON value caused an invalid JSON error in PRTG Desktop, leaving the device entry stuck in loading indefinitely, even though the same device and sensor loaded correctly in the PRTG web interface.
We fixed an issue for Device Settings where the Windows Compatibility Options section was displayed twice. The second, shorter section was an obsolete remnant from a previous implementation and was no longer functional. You will now only see one available Windows Compatibility Options section in the Device Settings again.
With this PRTG version, we deprecate the HTTP Full Web Page sensor that we already announced with PRTG Stable version 26.3.122.1665. You cannot add this sensor anew when you update to this PRTG version, however, existing sensor types continue to run. We recommend that you use the HTTP Webpage Sensor (BETA) instead.
With this PRTG version, we deprecate the SSH Disk Free sensor. You can no longer create this sensor type when you update to this PRTG version, however, existing sensor instances continue to run. You will also receive an according TO DO ticket in PRTG. We recommend that you use the successor sensor SSH Disk Free v2 instead. For more information about sensor deprecation and discontinuation, please see our Knowledge Base article: What do deprecation and discontinuation in the context of a sensor mean?
With this PRTG version we discontinue the Common SaaS sensor. We announced the deprecation of the Common SaaS sensor with PRTG version 25.3.110. Please note that existing Common SaaS sensors will stop working when you update to this PRTG version. It is not possible to create a Common SaaS sensor anymore. For more information about sensor deprecation and discontinuation, please see our Knowledge Base article: What do deprecation and discontinuation in the context of a sensor mean?
As of PRTG Stable version 26.3.122.1665, the AI Chatbot Max previously available on the Welcome Page in PRTG New UI is no longer accessible in PRTG until further notice.
We currently face an issue where you cannot edit the License Key or License Name on the /settings/status/license/activation page in the New UI. The License Key or License Name wont be changed when you click on Update License. This issue also affects the option Activation Type that does not display the settings when you selected Manual (offline activation). Please use the PRTG classic web interface in this case when you want to make changes to your license.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
With this release, version 26.3.124.1728 is also available, as we are currently executing an A/B test. This version will therefore only be displayed for installation if you are in the corresponding group for a PRTG trial installation via website download. Apart from all changes that are included in 26.3.124.1727, this version comes with improvements and new features for our New UI.
You can try out the experimental SIMATIC S7-1200/1500 Alarm Status sensor (BETA) with this PRTG version, which uses the S7 Web API's Alarms.Browse function to monitor active and unacknowledged alarms on your Siemens S7-1200/1500 PLC, including the critical case where the PLC stays in RUN while a process alarm remains active and unaddressed. The sensor reports the number of unacknowledged active alarms in Unacknowledged Active Alarms as primary channel, alongside total active alarms broken down into program, system, and other alarm categories, and shows the text of the most critical active alarm as the sensor message. This sensor requires Credentials for S7 Web API in the device settings.
We introduce a new feature Alarm Insights in the New UI. It is available on the left side menu bar. The feature helps you analyze alarms, acknowledge them directly, and get suggestions on how to resolve them. Alarm Insights is currently available as an early access preview. You can sign up to participate via a link that takes you to the registration page.
You are now able to simulate an error status via context menu Simulate error status for sensors. Once a sensor is in simulated error state, resuming it clears the simulated error.
With this PRTG version, we introduce the new Dependencies view in the New UI, so you can review your objects' dependency tree without switching to the classic interface. A new Dependencies entry in the main navigation takes you to an overview page with three tabs — Overview, Selected Dependencies, and Master Dependencies — and you can click any object in the graph or tables to jump directly into its dependency view.
We fixed an issue where in certain cases submitting forms that use iFrames in the New UI briefly displayed the classic PRTG interface in the background.
You can now access Libraries directly from the main navigation menu in the New UI. The new Libraries entry is placed between Monitoring and Maps and loads the Libraries page in the main content area. The Management tab is visible to read/write users only. The History tab requires admin rights. The right-click context menu is available on Library and Library Node objects in the Overview tab only.
We fixed an issue in the Map Designer where clicking on objects in a Data Table did not navigate correctly within the New UI. Previously, clicking a sensor's graph opened the sensor overview in the classic UI instead of the sensor's Graphs page in the New UI, and clicking on other objects resulted in a Something went wrong while loading the content error.
We fixed an issue where the mobile navigation header (hamburger menu) disappeared entirely when navigating into the Auto-Discovery Tasks module on a mobile device. The navigation header is now visible on all Auto-Discovery Tasks routes, so you can always open the main menu and navigate elsewhere, even though this module still shows a Not available on mobile message in the content area.
With this PRTG version, you can now use the Search option in the New UI, letting you search all your objects from anywhere in the interface and jump straight to a device, sensor, report, or ticket by name instead of navigating the object tree. A search input is now available in the header on every page; submitting a search takes you to a dedicated results page. The page also shows a loading state while searching, a hint when no term is entered, and an empty state with a quick way to clear your search and filters when nothing matches.
The primary channel of a sensor is now correctly displayed in the New UI when you changed it before in the Sensor Display settings in the PRTG classic interface.
You can now use the Recommended sensors feature in the New UI that is displayed on the sensor Overview page and which is available also via context menu. You can trigger the action by clicking on Recommend now. You can trigger a scan at any time to refresh recommendations, with a spinner shown while the scan is in progress, and an empty list if no recommendations are available. A success or error toast confirms the outcome after installing sensors.
We fixed an issue in the popup window for editing Schedules where saving with an empty Schedule Name field correctly blocked the save and showed the This field is required. validation error, but incorrectly also displayed the Settings have been saved. success toast at the same time. Now, only the validation error is shown when a required field is missing, and no success toast appears.
With this PRTG version, we introduce Insights, bringing the Top 10 Lists feature into the New UI. Insights appears as a new tab in the right-split layout monitoring view for Groups and Probes. From this view, every table link takes you to the Root Group's right-split layout monitoring view showing the correct sensor table, so you can move seamlessly from an overview straight into the relevant sensors.
20 New and Improved Sensors: PRTG 26.3.122 is Here
We just released PRTG version 26.3.122 to the stable release channel, and it brings a full package: seven brand new sensors, ten sensors that graduate from BETA, three experimental additions, and a range of security and server improvements
Read the complete blog post hereWith this PRTG version we introduce the new IP Reputation Score sensor, which is the successor to the IP on DNS Blacklist sensor. This new sensor lets you check whether the IP address of a device is listed on DNS-based blacklist servers (DNSBL). The sensor supports both IPv4 and IPv6 and is compatible with the Multi-Platform Probe.
You can now monitor network jitter also on the Multi-Platform Probe without requiring the .NET framework, using the new Ping Jitter v2 sensor. It supports IPv4 and IPv6 and provides four monitoring channels: Jitter (ms), Minimum, Average, and Maximum Response Time (ms). You can configure the timeout, ping count, ping delay and time to live. If no ping replies are received, the sensor reports an error message accordingly.
With this PRTG version we introduce the new Proxmox VE Cluster Health sensor that left its BETA status and is now fully supported. This sensor monitors the health status of Proxmox VE clusters. We introduced this sensor type as experimental BETA sensor with PRTG version 26.1.118.1380.
With this PRTG version we introduce the new Proxmox VE Container Status sensor that left its BETA status and is now fully supported. This sensor monitors performance metrics and status of LXC containers on Proxmox VE clusters. We introduced this sensor type as experimental BETA sensor with PRTG version 26.1.116.1498.
With this PRTG version we introduce the new Proxmox VE Node Performance sensor that left its BETA status and is now fully supported. This sensor monitors performance metrics and status of Proxmox VE host nodes. We introduced this sensor type as experimental BETA sensor with PRTG version 26.1.118.1380.
With this PRTG version we introduce the new Proxmox VE Virtual Machine Status sensor that left its BETA status and is now fully supported. This sensor monitors performance metrics and status of QEMU virtual machines on Proxmox VE clusters. We introduced this sensor type as experimental BETA sensor with PRTG version 26.1.116.1498.
With this PRTG version we introduce the new REST JSON Data sensor that left its BETA status and is now fully supported. This sensor accesses a Representational State Transfer (REST) application programming interface (API) endpoint and retrieves JavaScript Object Notation (JSON) encoded data. We introduced this sensor type as experimental BETA sensor with PRTG version 25.3.110.1313.
With this PRTG version we introduce the new RDP Client-Side Check sensor, which is the successor to the RDP (Remote Desktop) sensor. This sensor monitors the availability and response time of the RDP service on Windows systems. It establishes a TCP connection to the configured port and measures the time until the connection is accepted. It performs no authentication but it verifies the RDP handshake via the initial server packet. Please note that this sensor type does not support TLS connection.
With this PRTG version we introduce the new SSL/TLS Security Check sensor that left its BETA status and is now fully supported. The SSL/TLS Security Check sensor monitors the security of a connection secured by Secure Sockets Layer (SSL)/Transport Layer Security (TLS). We introduced this sensor type as experimental BETA sensor with PRTG version 26.1.118.1380.
With this PRTG version we introduce the new SSL/TLS Certificate sensor that left its BETA status and is now fully supported. This sensor monitors the certificate of a connection secured by Secure Sockets Layer (SSL)/Transport Layer Security (TLS). We introduced this sensor type as experimental BETA sensor with PRTG version 26.1.116.1498.
With this PRTG version we introduce the new SNMP Custom v2 sensor that left its BETA status and is now fully supported. The SNMP Custom v2 sensor monitors a single parameter that is returned by a specific object identifier (OID) or Abstract Syntax Notation One (ASN.1) Management Information Base (MIB) via the Simple Network Management Protocol (SNMP).
With this PRTG version we introduce the new SNMP Traffic v2 sensor that left its BETA status and is now fully supported. The SNMP Traffic v2 sensor monitors bandwidth and traffic on a device via the Simple Network Management Protocol (SNMP). We introduced this sensor type as experimental BETA sensor with PRTG version 23.3.88.1393.
With this PRTG version we introduce the new SSH Script v2 sensor that left its BETA status and is now fully supported. This sensor connects to a Linux/Unix system via Secure Shell (SSH) and executes a script file that is located on the target system. This sensor type is the successor sensor of the SSH Script sensor. We introduced this sensor type as experimental BETA sensor with PRTG version 25.2.108.1358.
With this PRTG version we introduce the new Traceroute Hop Count v2 sensor that runs also on the Multi-Platform Probe without requiring the .NET framework. This sensor reports the number of hops from the probe to the parent device, displaying the full route in the sensor message so you can immediately see any path changes. If the parent device is unreachable, the sensor goes into a down state with a meaningful error message. The sensor supports IPv4 and IPv6 and is compatible with both Classic Probe and Multi-Platform Probe. Please note that this sensor does not yet support the If Route Changes sensor setting like the already existing Traceroute Hop Count sensor.
You can now monitor the performance of your Microsoft SQL Server instance with the new WMI Microsoft SQL Server sensor. The sensor supports SQL Server versions 2005–2025, including multiple parallel installations, and works on Classic Probe and will be supported on the upcoming Multi-Platform Probe for Windows. Please note that this sensor type only supports WSMan protocol for WMI connections.
With this PRTG version we introduce the new WMI Volume v2 sensor that monitors free disk space on a single Windows volume, including drives, logical volumes, and mount points. This sensor type is the successor to the WMI Volume and WMI Free Disk Space (Multi Disk) sensor. Please note that this sensor type only supports WSMan protocol for WMI connections.
With this PRTG version we introduce the new VMware Datastore (REST) sensor that monitors the disk usage and availability of VMware datastores via the vSphere REST API. One sensor instance is created per datastore and serves as an alternative to the existing VMware Datastore (SOAP) sensor. The sensor reports free space, available capacity, accessibility status, datastore access mode, VM count, disk count, and VM power states. The sensor enters an error state when the datastore becomes inaccessible, the API is unreachable, or authentication fails.
We changed the error message handling for EXE/Script and EXE/Script Advanced sensors. PRTG will no longer print error messages in the sensor message. Please check your sensor logs in case of errors with your custom scripts.
We hardened PRTG against possible Cross-Site Scripting (XSS) attacks in terms of channel names and lookup values.
With this PRTG version we improve the PRTG Installer process for NatsManager updates. If the PRTG installer detects a new NatsManager version, it now takes a snapshot of the current configuration, saves the old binary, and replaces it with the new one without deleting or reconfiguring the existing setup. This eliminates the previous full uninstall and reinstall of the entire NATS system including the NatsServer.
We now support the Acknowledge Automatically option for all sensors in the Scanning Interval sensor settings. This option supports Show down status on error (default) and Show down (acknowledged) status on error.
With this PRTG version we added HTTP Proxy support for the SSL/TLS Security Check sensor and SSL/TLS Certificate sensor. The sensor will use the HTTP Proxy server settings if you have configured them in the device settings.
Various other minor fixes and improvements, updated user manual.
We updated the German, Spanish, French, Portuguese, Russian and Chinese language files.
We updated the German and Spanish language files for certain sensor types.
Your Database Health (Autonomous) sensor will be removed from your PRTG installation when you update to this PRTG version or future versions. The Database Health (Autonomous) sensor was created upon installation of PRTG version 26.1.118.1380 that includes the PRTG Database. With PRTG version 26.2.120.1449, we have already removed the files and components from the PRTG Database which will no longer be installed for new installations.
With this PRTG version your existing custom device templates will be migrated for the following sensor types to their successor sensors: SNMP System Uptime (SNMP Uptime v2), SSH Disk Free (SSH Disk Free v2) and SNMP Memory (SNMP Memory v2) sensor. PRTG will store a copy of the original device templates in the folder PRTG Network Monitor/devicetemplates/backup. The migration happens when you update to this PRTG version. For more information about device template migration, please see our Knowledge Base article: https://helpdesk.paessler.com/en/support/solutions/articles/76000085400-what-is-a-sensor-or-device-template-migration-
New PRTG installations now use WSMAN as the default monitoring protocol instead of DCOM. Existing installations continue to use DCOM without any changes, and you can switch to WSMAN at any time using the new global activation toggle in the UI. PRTG will also create a To-Do ticket for existing installations, informing you that WSMAN is now the default for new setups, that Kerberos is available.
PRTG will uninstall the PRTG (PostgreSQL) Database and its files and components when you update to this PRTG version and if you have previously installed the PRTG version 26.2.118 that includes the PRTG Database. This update process, which involves removing the PRTG Database, only occurs if you have not activated the PRTG Database. If the PRTG Database is activated and contains data, you will receive a message in the installer explaining the next steps when you update to this version.
The Core & Probes tab in the PRTG System Administration section is now divided into two clearly separated sections, Core Server and Probes, so you can easily distinguish which settings apply to the PRTG core server and which apply to PRTG probes. This change also applies to the PRTG New UI.
After activating your PRTG license and restarting the Core Service, successful license activations are no longer incorrectly logged as errors in Core.log. Previously, a successful activation triggered a misleading error entry such as Error during activation of license [...]: Activation was successful. This issue occurred only at the DEBUG log level.
We fixed an issue where renaming a Multi-Platform Probe in the PRTG UI was reset to the default name after a Core server restart. If you renamed your probes you would unexpectedly see the changes reverted in previous PRTG versions. The name you set in the PRTG UI now always takes precedence, even if the name is later changed in the MPP configuration, the UI name is retained. Please note that this fix also applies to classic probes, which will no longer revert to their connection-time name when renamed during an active connection.
We fixed an issue that occurred when you updated from an older PRTG version, i.e. 26.1.116.1498, to PRTG version 26.1.118.1380 or later where the NATS server certificate could not be imported in certain cases. The update would fail with a NATS setup error in the installer. The issue only occurred if you had PRTG installed with a non-integrated NATS server, that is prior to version 26.1.118.1380 and you updated to a newer version.
You can now use again the option Create Configuration Snapshot under the section Administrative Tools for the PRTG Core Server in PRTG. In previous PRTG versions, the button Go! did not trigger any action to create a configuration snapshot in the Configuration Auto-Backups folder.
After an unexpected SSH disconnection, the SSH Script v2 sensor now correctly uses the newly established SSH session for all subsequent scans. Previously, after a successful reconnect, the probe fell back to the previous session object, causing repeated authentication failures (e.g., ssh_userauth_publickey: Out of memory) every 60 seconds with no automatic recovery. A possible workaround was to manually pause and resume the sensor.
We fixed an issue where only the first created sensor name instead of the sensor type was displayed in the Create Template Results pop-up window after template creation. This issue happened, for example, for the SNMP Traffic v2 or Microsoft 365 Service Status Advanced sensor where more than one sensor is created.
When using the HTTP v2 sensor with the POST request method, you can now set a custom Content-Type header (e.g. application/json) and the sensor will correctly apply it to outgoing requests. Previously, the sensor ignored the configured value and always sent application/x-www-form-urlencoded instead.
We fixed an issue that occurred in the authentication process of the Network Share sensor to the remote server.
We fixed an issue for the Redfish Power Supply sensor that reported an error with the message The requested resource was not found on the remote server after an HPE iLO firmware update to version 1.22.00 in certain cases.
We fixed an issue where using Auto-Discovery with a template to create the SSH Disk Free v2 sensor produced one separate sensor per Linux mount point, each containing all detected mount points as channels. PRTG now correctly creates a single sensor with one channel per mount point.
We fixed an issue where it was possible to click an Add sensor button for the PRTG Core Server device, which resulted in an error with the message: Autonomous objects do not support this operation. The Add sensor button is now hidden for devices that do not support this option. We fixed this issue also in the New UI.
You can now use the Show as Gauges view on the Alarms page as expected. Previously, switching to this view resulted in a blank page showing raw JSON data instead of gauge widgets. This affected any sensor that included HTML content in its status message.
We fixed an issue where Chromium-based browsers experienced significant delays or timeouts when loading pages in the Classic PRTG Web UI. The issue was caused by certain Chrome extensions using postMessage to communicate with the application, a confirmed example is the Angular DevTools extension. Firefox was not affected. You can now use Chromium-based browsers with extensions installed without experiencing indefinite loading times.
The configuration file of this version is not downwards compatible with previous PRTG versions.
We currently face an issue where the Windows Compatibility Options section is displayed twice. The second, shorter section is an obsolete remnant from a previous implementation and is no longer functional. Any settings configured in this second section will not be applied to any sensors. As a workaround please use the first Windows Compatibility Options section that appears on the page. This is the only section that is active and where your configuration will be correctly applied. We will deliver a fix for this issue with a future PRTG version.
We currently face an issue where logging in via Single Sign-on results in a 404 error when you use a non-default (custom) HTTPS port for the Web UI. Instead of preserving the configured custom port after the login callback, SSO login redirects to the default port (443) in those cases. This can cause the request to hit the wrong service (e.g. the probe port) and result in an error. We will provide a fix for this issue in an upcoming PRTG version.
With this PRTG version we announce the upcoming deprecation of the HTTP Full Web Page Sensor. You cannot add this sensor anew when you update to upcoming PRTG version 26.x.123, however, existing sensor types continue to run. We recommend that you use the HTTP Webpage Sensor (BETA) instead. You will receive an according PRTG TO DO ticket when you update to this PRTG version.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
You can now monitor the complete loading time of web pages, including all resources such as images, scripts, and stylesheets when you try out the experimental HTTP Webpage (BETA) sensor. This sensor is the successor to the existing HTTP Full Web Page sensor. The sensor uses a headless Chrome browser on the probe machine to load the requested URL and alerts you when loading times exceed defined thresholds. This sensor also supports the Smart URL Replacement feature, which adds the device host in the URL field of a HTTP sensor automatically when you enter https:///.
You can try out the experimental SIMATIC S7-1200/1500 CPU Status sensor that monitors the operating state, cycle times, and load of Siemens SIMATIC S7-1200 and S7-1500 PLCs via the S7 Web API (JSON-RPC). This sensor automatically detects firmware capabilities and redundant CPU configurations, cycle time and load channels only appear when the device reports them, so older firmware is supported gracefully. Available channels are Operating Mode, Mode Selector, Cycle Time Events, for example. The channels Operating Mode (R2) and Mode Selector (R2) are dynamically created when redundancy is detected. Please note that the SIMATIC S7-1200/1500 CPU Status sensor does not work on S7-1200 G1 devices because of the S7 Web API integration. This sensor supports S7-1200 G2 PLCs.
You can try out the experimental WMI Service v2 sensor that is the successor to the WMI Service sensor. You can select the services during sensor creation. The sensor will report if services are stopped or paused. If you want to use WSMAN for WMI connection, please make sure to enable WSMAN protocol on the target device. Please note that this sensor type only supports WSMan protocol for WMI connections and that the option to change the Preferred Data Source in the Windows Compatibility Options is not available for this v2 sensor type. If you want to use a non-administrator Windows account for WMI monitoring via the WSMan protocol, please see the Knowledge Base article: https://helpdesk.paessler.com/en/support/solutions/articles/76000088235
With this PRTG version we introduce the new Auto-Discovery Job that lets you manage all your Auto-Discoveries and review their outcomes from one central place in PRTG. You can now create, edit, and delete Auto-Discovery Tasks directly from the overview page. Use the new button Create Task to create a task under any probe you have write access to. The button is grayed out if you have no write permissions on any probe. Required fields are validated, and you are redirected to the overview after a successful creation. Please note that this feature currently only works if you are logged in as a user with administrative user rights for the local probe.
We fixed an issue where it was possible to create a group via Add Group button in the action items without entering a value in the mandatory fields. The settings window was closed after you clicked create and an error would occur: The validation of at least one of the new objects failed because of the following: IPv4 Base: Required field, not defined. The object was not created.
The dependency field now displays the root of the dependency chain. Previously, the dependency of an object was only displayed to its immediate dependency.
We fixed several issues with the approval flow for unapproved probes in the device tree. Previously, the Approve and Deny buttons reappeared after approving or denying a probe instead of disappearing. They now correctly disappear after approval and the sensors and devices of that probe become visible as expected. The buttons now remain visible under an unapproved probe regardless of whether the tree node is expanded or collapsed. The approval or denial notification is also restricted to users with Write permission and pops up immediately upon login if an unapproved probe is present.
We reduced the loading time for iframes on the PRTG System Settings page in the New UI.
The New UI now surfaces Toplists for all sensors that support them. You can view and navigate Toplists directly from the sensor overview and a dedicated Toplists tab. Sensors that support Toplists are, for example, NetFlow v5, sFlow sensor, IPFIX sensor and Packet Sniffer sensor. An Add Toplist button is available on the Toplists detail page to create new Toplists for the sensor.
As of PRTG Stable version 26.3.122.1665, the AI Chatbot Max previously available on the Welcome Page in PRTG New UI is no longer accessible in PRTG until further notice.
We have replaced the following PRTG API v2 endpoints that were already announced as deprecated in the Open API Specification: probes/{id}/overview, groups/{id}/overview, sensors/{id}/overview and channels/{id}/overview. Those endpoints were replaced with probes/{id}, groups/{id}, devices/{id}, sensors/{id} and channels/{id}. Please note that the endpoints marked as deprecated will be removed in the future. In course of this, the Lookups endpoint will move to the Channels endpoint /experimental/channels/lookups/.
Three New Sensors, Smarter Monitoring: Prtg 26.2.120 is Here
We just released PRTG version 26.2.120 to the stable release channel, and it comes with a lot to talk about. Three new sensors graduate from BETA or join the lineup for the first time, a brand-new AI chatbot lands in the New UI, and a range of security hardening measures, server improvements, and sensor fixes round out this release.
Read the complete blog post hereWe fixed an issue for the Syslog Receiver sensor that did not receive and display Syslog messages anymore in the previous PRTG version when you had configured Syslog messages with notification template Send Syslog Message.
We fixed an issue that caused gauge widgets to stop rendering in the sensor overview and on maps in certain cases when the target device for that sensor was not reachable and the sensor was in Down status. The issue happened, for example, for the Ping v2 sensor that measures float values and that could report non-numeric values (NaN or INF) when a monitored target became unreachable.
You can now fully access the Custom HTML map item properties in Map Designer again when you update to this PRTG version. Previously, selecting the Custom HTML option in the Properties panel caused an endless loading state, preventing the HTML fields from appearing.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Stable 26.2.120.1477
With this PRTG version we introduce the new SNMP Custom String v2 sensor that monitors a string returned by a specific object identifier (OID) via the SNMP. The sensor interprets the SNMP value returned by the OID as a string, a MAC address, or an IPv4 address and shows the interpreted value in the sensor message. We introduced this sensor as experimental BETA sensor with PRTG version 26.1.116.1498.
We added the new SNMP Printer v2 sensor to monitor printer status, consumables, and operational metrics via SNMP. The sensor supports IPv4 and IPv6. Depending on the monitored printer, the sensor creates the channels Total Pages Printed, Cover Status, Tray Status and Supply Status. The sensor message displays the printer console output. If no printers are defined in the device table, the sensor will report an error. This sensor introduces 1-based numbering for printer units, as well as removing ranged lookups in favor of direct percentage and lookup values.
With this PRTG version we introduce the new SNMP RMON v2 sensor that was rewritten to work also on the Multi-Platform Probe. The SNMP RMON v2 sensor monitors traffic on a device using the Remote Monitoring (RMON) standard via SNMP. In the Specific Sensor Settings you have the option to edit the settings Description or 64-bit on request. This information is collected during sensor creation and if 64-bit counters are enabled in the compatibility settings.
With this PRTG version we introduce the PRTG Installation Report, a new built-in report available by default in all standard PRTG installations under Reports menu. With this report you can collect data about your PRTG installation, including license information, system health and optimization recommendations. The report can be generated on-demand or scheduled for automated delivery. The report supports PDF, CSV and HTML formats.
For more information, please refer to the following Knowledge Base article: Vulnerabilities in PRTG prior v26.2.120.1449 | Paessler Knowledge Base
The Microsoft 365 Mailbox sensor now supports the setting Validate Latest Email, like for example, the IMAP sensor. The sensor will use the latest email from the filtered messages. If no filters are configured, all messages are taken into account. You can configure warning or error states based on the Subject, From or Body settings. Additionally, you can set the sensor to Down or Warning status based on age for the latest email.
Various other minor fixes and improvements, updated user manual.
In case of a manual update to this PRTG version and if you have previously activated the PRTG Database, you will see an installation window with the message that the installation has stopped in order to keep your existing data. This is due to a new schema update in this PRTG version. The installation window will provide further instructions on how to proceed with the update.
The auto-update process will currently stop when you update to this PRTG version if you have previously activated the PRTG Database and have existing data. This issue affects you if you have set your auto-update to Automatically download and install in the Software Auto-Update settings. PRTG will create a TO DO ticket Error: The update cannot continue due to a change in the database schema if you run into this issue. For more information, please see our Knowledge Base article: https://helpdesk.paessler.com/en/support/solutions/articles/76000088264
We updated the list and location of the example scripts for custom sensors in the PRTG program directory. This removes all Demo scripts from the pre populated custom scripts directory. Scripts that were not deemed as risky are preserved under the examples script directory. Additionally, we have updated the example scripts for Script v2 to follow a more modern structure. Please note that in course of this change that we removed any .dll and .exe demo binary from PRTG.
To be consistent with our changes in PRTG version 26.1.118.1380 to display information about sensor usage and licensing in the New UI, we removed the Number of Sensors part under License Information on the PRTG System Status page.
We fixed an issue where in certain cases an enabled Geo Map could lead to ajax timeout errors or slow performance in the PRTG web interface. You could observe this issue when your PRTG core server was blocked in your firewall for outgoing connections and PRTG would try to reach the geolocation service continuously. A possible workaround was to disable Geo maps.
We fixed an issue where in certain cases an enabled Geo Map could lead to ajax timeout errors or slow performance in the PRTG web interface. You could observe this issue when your PRTG core server was blocked in your firewall for outgoing connections and PRTG would try to reach the geolocation service continuously. A possible workaround was to disable Geo maps.
We fixed an issue where the PRTG core service used a large amount of memory in rare cases which caused the system to run out of memory in the end. You could find the error message out of memory in the core log file in such cases.
We fixed an issue for the NetApp SnapMirror v2 sensor which regularly went into an error state and did not return any values for certain channels. The ONTAP API omitted transfer fields for continuously synced relationships and the sensor would handle the missing values as error. The issue happened when you used ONTAP with SnapMirror Active Sync and Consistency Groups.
We have improved the DNS v2 sensor regarding filtering reliability and result consistency. Null MX records are now correctly displayed as 0 if a domain does not accept emails, and DNS records of the same type are now sorted alphanumerically to ensure consistent output across repeated requests. Record values are trimmed before filter matching to prevent whitespace-related mismatches. A new Match the full result exactly filter mode has been added for record types whose values naturally contain commas, such as TXT and NAPTR. The internal connectivity check now queries the root domain for NS records instead of using a localhost ANY query, improving compatibility with modern DNS servers.
We fixed an issue where Run Auto-discovery with Templates led to an error (bad request) when you selected device templates via multi edit. Previously, it was only possible to select device templates on the first page of the pop-up window. As soon as you selected a device template on the second page or beyond, an error message appeared stating no device template had been selected.
We fixed an issue for Desktop Client and MultiBoard related API keys that you can create in PRTG via Add API Key for PRTG MultiBoard button. The issue happened when you started the Single Sign-on login flow calling getdesktoptoken.htm. The API key that was returned from the endpoint did not work for Single Sign-on content in those cases.
We currently face an issue where it is not possible to log in via Single Sign-on after enabling PRTG Database for data migration. If you have set up Single Sign-on before and migrated your configuration to PRTG database, the login with Single Sign-on would fail afterwards. In the User Group Settings you could observe that the SSO Group Claim was missing. A possible workaround is to set up a new Single Sign-on user group.
Please note that with updating to this PRTG version, the auto-update process takes longer because it includes the PRTG database and related components, which increase the size of the PRTG installer. We strongly recommend that you do not restart PRTG during this process and wait until the update is complete.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Stable 26.2.120.1449
We fixed an issue where sensor tags were lost after migrating configuration and monitoring data to the PRTG database. This caused sensors to become invisible in tag-based filters, making libraries and reports that rely on tag filtering no longer work as expected. This issue applied to the WMI Free Disk Space (Multi Disk) sensor, for example.
We improved the retry mechanism for the SIMATIC S7-300/400 CPU Restart Overview sensor to reduce false alerts caused by intermittent errors when querying data from a PLC via S7. Previously, the PLC would occasionally return a CPU : Item not available error, causing the sensor to go into a down state for one or more scans before recovering, despite the PLC working correctly the whole time. When the PLC is too busy to serve the request of the sensor, the request is now retried after a delay of 100 ms, with a configurable maximum delay of up to 1000 ms.
We fixed an issue for the SNMP Traffic v2 sensor that wrongly displayed 4 GBit/s as a result for unconnected ports in certain cases. The issue happened mostly for SNMP version v1 or high speed interface connections. The sensor will now display the status Unknown correctly for non-available entries instead of a wrong value.
We fixed an issue where the Channel Unit Configuration did not display the correct units for Disk size, File size and Memory size.
We fixed an issue for the object tree under Monitoring where object calculation did not work properly for groups that contained only empty objects (groups or devices) and no sensors.
You are now able to use the following Device Action buttons via context menu: Reorder Tree, Copy and Paste. After you have copied an object, a success message appears. The same applies to the object once you have successfully pasted it. If you do not have the necessary access rights to an object, the buttons in the context menu will appear disabled and display the text no permission.
We fixed an issue where in certain cases an unknown error occurred with the message Something went wrong. Please refresh your browser or try again later. The issue in the new UI happened sporadically and in cases when you closed the browser and opened PRTG again with a page using iframes.
Prtg 26.1.118 is Now Available in the Stable Release Channel
We just released PRTG version 26.1.118 to the stable release channel - and this one is packed. The highlight of this release is the first Beta of PRTG Database, a brand-new PostgreSQL-based storage layer designed to boost efficiency and speed in large PRTG installations. On top of that, you get two new experimental sensors for Proxmox VE, the new SNMP Windows Service v2 sensor, a rewritten...
Read the complete blog post hereWith this PRTG version we introduce the new SNMP Windows Service v2 sensor that was rewritten to provide improved reliability and maintainability. This sensor monitors a Windows service via SNMP and uses credentials in Credentials for SNMP Devices that you have to configure in the device settings.
We improved the authentication implementation of PRTG to defend against potential timing attacks and username enumeration. CVE is still pending.
For more information, please refer to the following Knowledge Base article: Vulnerabilities in PRTG prior v26.2.120.1449 | Paessler Knowledge Base
With this PRTG version we support authNoPriv as Authentication Method for SNMP sensors and SNMP version v3. The authNoPriv mode enables you to monitor infrastructures that only allow authentication without encryption. To use this authentication method, you have to select None as Encryption Type in the credentials for SNMP devices to disable encryption.
To follow up with the NTLM deprecation process from Microsoft and as a first iteration to support Kerberos for WMI sensors, we have implemented a toggle to use WSMan for WMI connections in the PRTG Administration Tool. In the Probe Settings for Monitoring you will see an additional radio button where you can select Use WSMan for WMI connections, however, DCOM is still activated by default. You can set WSMan for WMI connections for each probe.
In the PRTG settings Credentials for Windows Systems you can select the option Only Kerberos as WMI Authentication Method. To use the Only Kerberos setting, please enable the WSMan protocol on the probe system in the PRTG Administration Tool before. You can also select Negotiate (Kerberos, Fallback to NTLM) in the WMI Authentication Method when WSMan protocol is active. In this case, PRTG will establish a connection using Kerberos authentication.
Various other minor fixes and improvements, updated user manual.
We updated the German and Spanish language files.
We updated the German and Spanish language files for certain sensor types.
To give you an improved and accurate view of Maintenance Days Left and Sensors Available, we have removed the widget on the page welcome.htm in PRTG and replaced it with a link to the New UI. The button Need Accurate License Details? links you to the New UI which provides a transparent and consistent overview of sensor usage. In course of this, we have removed the Number of Sensors count on the License Status page in the classic web interface.
Important: You have to enable the PRTG API v2 and New UI on the setup.htm page first to be redirected to the new license overview in the New UI.
We fixed an issue in the PRTG Administration Tool where strings in buttons e.g. were truncated for certain languages. Affected tabs were, for example, PRTG Application Server and NATS Server when you opened the PRTG Administration Tool in German.
We fixed an issue in the device settings for Credentials for Microsoft 365 that occurred when you entered an invalid Tenant ID. In this case, you would receive a bad request error message, however, the changes were saved and you were not able to change any other device settings afterwards.
We fixed an issue for Folder sensors that occurred when you have monitored network shares that contained certain utf-8 special characters in their file names. In the Result of Sensor logfile you could see the following error message: No mapping for the Unicode character exists in the target multi-byte code page.
We fixed an issue for the Ping v2 sensor where the channel Status was not set as primary channel when you had the setting Inverted Error Status enabled.
We fixed an issue for the Microsoft 365 Mailbox sensor when you have selected "...matches regular expression" in the Filter Messages for Subject, Form and Body. The issue occurred in cases when you used an invalid regular expression. The sensor would display an error message that was only partially translated in these cases.
We fixed an issue for the SNMP Disk Free v2 sensor that reported a broken error message and could not read the disk when the disk name contained certain language characters. Any non-conforming character in the disk name is now translated into its hexadecimal representation. Please note that you must recreate the sensor for these changes to take effect.
The SSH Disk Free v2 sensor now detects all available filesystems during sensor creation for Linux distributions. Previously, the sensor did not offer and create all available filesystems as channels like its predecessor SSH Disk Free which resulted in missing channels afterwards.
The configuration file of this version is not downwards compatible with previous PRTG versions.
To update to subsequent PRTG versions, you must first install the following PRTG version: 26.1.116.1532 Stable. PRTG 26.1.116.1532 serves as an intermediate version when you want to update from older PRTG versions to subsequent versions. This step is necessary because we had to update our code signing certificates.
This release contains a new code signing certificate and a corresponding intermediate version which will cause the auto-update process to run two times, please be informed that this could lead to longer update times and multiple reboots.
Important: If you update your PRTG manually, please note that you need to update to the intermediate version 26.1.116.1532 first before you are able to update to the released PRTG version 26.1.118.1380.
We currently face an issue in the PRTG API v2 for the new endpoint
Please note that with PRTG version 26.1.118.1380, the auto-update process takes longer because this version and subsequent ones include the PRTG database and related components, which increase the size of the PRTG installer. We strongly recommend that you do not restart PRTG during this process and wait until the update is complete.
In certain cases, the PRTG core server does not start anymore after updating to PRTG 26.1.118 and the log file core.log contains the message:
The issue mainly affects PRTG installations that are offline or have limited access to the internet and happens if the code signing signature fails due to a missing trust chain in the trusted root certificates of the Windows certificate store.
You can resolve the issue by adding the trusted root certificate for timestamp signature. For more information, see the Knowledge Base article After updating to PRTG 26.1.118, the PRTG core server does not start anymore.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Stable 26.1.118.1380
With this release, version 26.1.118.1381 is also available, as we are currently executing an A/B test. This version will therefore only be displayed for installation if you are in the corresponding group for a PRTG trial installation via website download. Apart from all changes that are included in 26.1.118.1380, this version comes with improvements and new features for our New UI.
With this PRTG version we introduce PRTG Database, developed for data processing and storage in PRTG as a first Beta release. PRTG Database is designed to increase efficiency and speed, especially in large installations with many sensors and data points. It is an alternative to file system storage and uses PostgreSQL to store raw monitoring and configuration data. The PRTG Database will install files and components automatically when you update to this PRTG version, however, it is currently deactivated by default.
Important:
PRTG will create the Database Health (Autonomous) sensor automatically when you update to or install this PRTG version 26.1.117. The sensor is created within the PRTG Core Server group and monitors the PRTG Database service as a first iteration. The sensor will report an error if the PRTG Database service is not running.
You can try out the experimental Proxmox VE Cluster Health sensor (BETA) that monitors the health status of Proxmox VE clusters. Available channels for this sensor type are Quorum Reached, Active Nodes, Online Nodes and Total Nodes. To use this sensor type, please enter the Credentials for Proxmox in the device settings with API token authentication. Please note that the channel Ceph Status is optional and is only available when you have configured a Ceph file system before.
You can try out the Proxmox VE Node Performance sensor that monitors performance metrics and status of Proxmox VE host nodes. To use this sensor type, please enter the Credentials for Proxmox in the device settings with API token authentication.
We improved the SIMATIC S7-300/400 CPU Status sensor (BETA) which now displays the Maximum OB1 Cycle Time in the Specific Sensors Settings if you have set it before during sensor creation. The Maximum OB1 Cycle Time describes the maximum cycle time for the program cycle organization block (OB1) what PRTG uses to calculate the value of the Cycle Ratio channel.
You can try out the experimental SIMATIC S7-300/400 LED Status sensor (BETA) which displays the status of all physical LEDs on the front panel of a SIMATIC S7-300 or S7-400 controller. The sensor will automatically create one channel per LED that is actually available on that monitored PLC model. Depending on the status of the LED, the sensor displays a message for the respective channel, which is mapped via lookup values. For example, Maintenance Required (MAINT) will show the status OK if the LED has the value OFF.
We improved the search method for the SNMP Custom String v2 sensor for search with wildcards and when you have set Interpret Result As to String (default) in the sensor Settings. The sensor has a new setting Search String Contains with the options Simple string (default), Wildcards and Regular expression. You can replace parts of your substring by wildcards, for example ? matches a single character. You can find the returned value in the channel String Found.
You can try out the experimental SSL/TLS Security Check sensor which is the successor to the SSL Security Check sensor. The SSL/TLS Security Check sensor supports modern protocols to ensure secure encrypted connections. Unlike the old sensor, TLS 1.3 is also supported. TLS 1.2 and TLS 1.3 are set as accepted (default) in the sensor settings Security Evaluation, whereas weaker protocols (SSL 3.0, TLS 1.0, TLS 1.1) are set to denied (default). This sensor type can also be created on the Multi-Platform Probe.
We fixed an issue where certain pages were displayed for a few seconds in the classic web interface. This issue happened sporadically and the new UI was displayed after automatic or manual refresh of the pages. This issue could affect the Maps and Reports pages, among others.
You can now enter and save notes in the new Comments tab which we have implemented for each monitoring object (Probe, Group, Device, Sensor level). You will receive a success message after saving your changes. Please note that the new Comments tab is not yet available on Mobile view. If you have existing comments in the classic web interface for that object, you will see the comments now also in the new UI.
We fixed an issue that occurred on the sensor Channel Overview page where unknown errors would be displayed. The issue happened after a certain page refresh interval, that is, after a page refresh you could observe an unknown error message toast.