• Company
    • About Us
    • Press Center
    • Careers
    • Blog
    • IT Knowledge
    • Contact us
  • Contact us
  • Login
 
  • English
    • Deutsch
    • Español
    • Français
    • Italiano
    • Português
Paessler
                    - The Monitoring Experts
  • Products
    • Paessler PRTG
      Paessler PRTGMonitor your whole IT infrastructure
      • PRTG Network Monitor
      • PRTG Enterprise Monitor
      • PRTG Hosted Monitor
      • PRTG MSP Edition
      • PRTG OT Edition
      • PRTG extensionsExtensions for Paessler PRTGExtend your monitoring to a new level
    • Icon Features
      FeaturesExplore all monitoring features
      • Maps & dashboards
      • Alerts & notifications
      • Multiple user interfaces
      • Distributed monitoring
      • Customizable reporting
      • Network Topology
  • Solutions
    • By TeamFor your organization size
      • Small Business IT
      • Mid-Market IT
      • Enterprise IT
      • MSP Network Monitoring
    • Industries
      By IndustryFor your business sector
      • Industrial
      • Healthcare
      • Energy
      • Government
      • Education
      • Data Center
      • Finance
    • IT Topics
      By Use CaseFor every technical scenario
      • Network Monitoring
      • Server Monitoring
      • OT Monitoring
      • Distributed Monitoring
      • Network Topology Mapping
      • SNMP Monitoring
      • Bandwidth Monitoring
  • Pricing
  • Resources
    • Getting Started
      Getting StartedModules for self-paced learning
    • How-to Guides
      How-to GuidesGet the most out of PRTG
    • Videos & Webinars
      Videos & WebinarsLearn from Paessler experts
    • Case StudiesProven results across industries
    • PRTG Manual
      PRTG ManualFull documentation
    • Knowledge Base
      Knowledge BaseShare community knowledge
    • PRTG Sensor Hub
      PRTG Sensor HubGet sensors, scripts & templates
    • Trainings
      PRTG TrainingLearn how to work with PRTG
  • Partners
    • Icon Handshake
      Become a PartnerFor resellers and channel partners
    • Icon MSP
      Become an MSPDeliver monitoring as a managed service
    • icon partner
      Partner PortalLog in to your partner account
    • Deal Registration
      Deal RegistrationRegister your sales opportunities
    • icon search
      Find a PartnerFind partners selling Paessler products
    • icon technology
      Technology AlliancesSee Paessler technology partnerships
    • Partner HubTools for Your Success
  • Company
    • About Us
    • Press Center
    • Careers
    • Blog
    • IT Knowledge
    • Contact us
  • Contact us
  • Login
  • English
    • Deutsch
    • Español
    • Français
    • Italiano
    • Português
  • Get a quote
  • Free trial
  1. Home>
  2. Paessler PRTG>
  3. Version history>
  4. Preview release notes

PRTG Release Notes:
Preview Channel

Early Access to New Features

  • Preview versions give you early access to the latest features and improvements before they reach the stable channel. These versions have been thoroughly tested in our labs, but may still contain limitations in certain monitoring configurations. We do not recommend using preview versions in production environments.
  • To update your PRTG installation with the latest preview version, use the Auto-Update feature: In the PRTG web interface, navigate to Setup | Auto Update.
  • Looking for the most reliable version for your live environment? Check out our Stable Release Notes.
Stable Channel
DOWNLOAD PRTG

PRTG Preview Version 23.2.84.1532

Release date: May 11, 2023

Blog article

Michael BeckerBy Michael Becker•Aug 13, 2024

PRTG 23.2.84 is available in the stable channel

Paessler PRTG 23.2.84 is now available in the stable release channel!This version comes with the new NetApp v2 sensors, the experimental SNMP Uptime v2 and SNMP Custom v2 sensors, and security improvements for certain sensor types. It also includes an update for the Chinese, Dutch, French, German, Japanese, Portuguese, Russian, and Spanish language files.Here are the details:

Read the complete blog post here
PRTG 23.2.84 is available in the stable channel
New

New

NetApp v2Sensors

The new NetApp v2 sensors NetApp Aggregate v2, NetApp I/O v2, NetApp LIF v2, NetApp LUN v2, NetApp NIC v2, NetApp Physical Disk v2, NetApp SnapMirror v2 Sensor, NetApp System Health v2 and NetApp Volume v2 support the new ONTAP REST API as of ONTAP 9.6.

We first introduced the new NetApp v2 sensors as experimental with PRTG version 22.3.79.2108 since NetApp delivers a new RESTful API for ONTAP based storage systems and former ONTAPI will reach end of availability soon. We received valuable feedback and in addition to the functionality that the sensor already had in the last PRTG version, we resolved one more issue for this release.

  • Your NetApp Volume v2 sensor now reports volumes correctly in a NetApp MetroCluster configuration setting. Previously, the sensor displayed an error with the message The queried field "space.available" is empty. when it was used in cluster configurations.


  • Note: Your running NetApp v1 sensors will no longer work when you update to ONTAP version 9.13.1. We already announced the deprecation of NetApp v1 sensors with PRTG version 23.2.83.1760.
Improved

Improved

SNMP v3Security

PRTG now supports the following encryption methods for SNMP v3 communication in the Credentials for SNMP Devices settings: AES192 and AES256 (Advanced Encryption Standard), SHA-224, SHA-256, SHA-384 and SHA-512 (Secure Hash Algorithms). Previously we only supported AES128 for encryption.

PRTG status pageSecurity

We hardened PRTG against possible data extraction from instances on the PRTG status page.

Sensor SecuritySensors

We improved the sensor types SMTP&POP3 Round Trip sensor, SMTP&IMAP Round Trip sensor and SMTP sensor which were not compliant to the Internet Message Format RFC 2822. Outgoing emails from PRTG to your (SMTP) server will no longer set a Message-ID field itself, but let the remote server add it. This applies to any other mail client.

All parts of PRTGVarious

Various other minor fixes and improvements.

Changed

Changed

PRTG default SSL certificateServer

We created a new PRTG default SSL certificate since the one in use will expire soon. The new certificate will be automatically set only if you make a fresh PRTG installation and not upon updating PRTG. If you have already installed PRTG you need to manually update it.
For more details, please see our Knowledge Base article https://kb.paessler.com/en/topic/283.

Probe TransferPRTG App for Desktop

You can now find the feature Probe Transfer in the Probe Connection Settings as it has left the Experimental Features section in the PRTG setup. This feature allows PRTG Desktop to access the configuration files of your probes to transfer a probe to another server. You still need to enable the feature first for your server in the Probe Connection Settings.

Fixed

Fixed

Map LayoutServer

You can now enter only valid pixel sizes for Map Width and Map Height in the Map Layout settings that range from 1 (min.) to 2147483647 (max.). Before it was possible to enter and save large numbers without limitation or negative numbers with the result that the map was not working afterwards.

Scanning IntervalServer

We fixed an issue in the Monitoring settings for the Scanning Intervals section. In previous PRTG versions you could enter and save an already existing scanning interval to Available Intervals with the same or with a different unit. For example, if you had a scanning interval of 60s you could add 60s as interval again or equivalent to it 1m.

SecurityServer

We fixed an issue for Microsoft 365 credentials that were displayed in a readable format in the Core Log. The issue only occurred for the Log in Debug Level. 

Docker Container StatusSensors

Your Docker Container Status sensors work properly again. In the previous PRTG version 23.2.83 they ran into an error with the message bad certificate in some cases.

Filtering and librariesSensors

Filter by type option in the main menu bar and in libraries now properly works for all sensors. Filtering by certain sensor types previously showed no sensors directly after PRTG updates and only after a server restart.

IPMI System Health sensorSensors

We fixed an issue that appeared in the IPMI System Health sensors that caused increased mutex timeouts.

Note

Note

PRTG Mobile Apps and PRTG DesktopKnown Issues

The login, via QR code and manually, to your PRTG Android and iOS App and the PRTG Desktop is currently not working for non admin user accounts when your PRTG is updated to version 23.2.84.1566. As a workaround, please use an admin user account instead. We will deliver a fix for this issue with an upcoming PRTG version.

Solved with PRTG 23.3.86.1520

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Preview 23.2.84.1562

  • sha256_exe 571020D5363B56692249F190B0728560A60C590EB89B0F7F63AEBFF791D5F210
  • sha256_zip 25A1199F80739374B678FD6695C11A648726CC2D7F98210E8D7AD01B8FCDC773


Stable 23.2.84.1566

  • sha256_exe 36E6237485ADFEECEB198038FD1040DAA42894B81A9325CCE9323EC17E326EE1
  • sha256_zip 0C039BA1704203C63456B1A2088AE2A3CA6C1E6E93ECBDFED862F87ABB27D2C0
Lab

Lab

Cisco MerakiSensors

We added a new setting Meraki Dashboard API EndPoint in the section Credentials for Cisco Meraki devices. With this field you can define your API endpoint for the sensor types Cisco Meraki License (BETA) and Cisco Meraki Netwok Health (BETA) after unlocking it. The setting resolves any issues on a device or group level where the API url has an extension other than .com.

REST Custom v2Sensors
  • You can now select unit types and lookups for each channel in the Channel Settings of your REST Custom v2 sensor. Input fields for Channel # Lookup ID and Channel # Custom Unit are now available. For custom units you can set a unit name now. Currently, all settings are visible when you enable the Channel # Custom Unit with Absolute (integer), Absolute (float) and Delta (counter) as value types. If you select lookup as channel type the sensor will be created using the given lookup file. Please note that you have to provide the name of the lookup during sensor creation for now when you want to select a lookup file and that the lookup can only be edited in the channel settings after sensor creation.
  • We improved the error handling of the REST Custom v2 sensor that will now display an according error message in case of an error and will run into an error status. For example, the error message will include the HTTP status code of the REST response in case the parsing fails due to invalid JSON.
SNMP Custom v2Sensors

You can try out the experimental SNMP Custom v2 sensor that we have rewritten to work on the Multi-Platform Probe. This sensor type comes with the same basic settings as the already existing SNMP Custom sensor. The SNMP Custom sensor monitors a single parameter that is returned by a specific object identifier (OID). The experimental SNMP custom v2 sensor will use both OID and MIB files.For more information about MIBs and how to use them please see our Knowledge Base article:https://kb.paessler.com/en/topic/91688.

SNMP Uptime v2Sensors

You can try out the experimental SNMP Uptime v2 sensor that we have rewritten to work on the Multi-Platform Probe. This sensor type comes with the same basic settings as the already existing SNMP System Uptime sensor including the additional Data Source setting under the section SNMP Uptime Specific, where you can select the object identifier (OID) the sensor gets its uptime from. The Data source is also depicted in the sensor status.

Script v2Sensors

We improved the Script v2 sensor to use a new JSON schema format. The sensor executes a Python script that returns data in JSON format and shows the exit code. This way you can create your own custom script sensors that may not be available in PRTG by default. Additionally the Type field in the sensor Settings has a new option Lookups. When you use lookups for Script Specific Type you need to set the lookup_name as property which defines the used lookup file. The Script v2 sensor now also supports unit kinds for the Type field that determine how a value is interpreted and therefore displayed. Kind can be custom, count, percent, for example. We also updated and improved the example scripts that are available during sensor creation. For available example scripts and how to use them, see the Knowledge Base article https://kb.paessler.com/en/topic/91349.

Device SettingsNew UI
  • We improved the Priority setting in the device Settings where you now can select a star rating.
  • We added the section Additional Device Information that displays the Service URL.
Web InterfaceNew UI
  • We fixed an issue with the Keyword filter action on sensor and channel lists. Previously the filter input would not return results with the search term from the primary channel column. With the new fix the filter returns the results from a group that includes the search term in the primary channel column. This action was fixed in a group, device, probe and sensor level.
  • We fixed an issue for the Automatic Refresh option in the PRTG Web Interface settings that occurred when you had the radio button Do not automatically refresh pages selected in the classic UI. The refresh timer was displayed in the new UI and returned an unknown error when you activated it. It is now hidden in the new UI when you have deactivated the Automatic Refresh option
  • We fixed an issue for the link different endpoints on the PRTG APIv2 card that did not open in a new browser tab before.
  • You can now clone a group with sensors that have channel limits without losing the given settings. Previously, the channel limits of a sensor were not adopted if you cloned the group of the sensor what could result in a wrong sensor status.

PRTG Preview Version 23.1.83.1742

Release date: March 30, 2023

Blog article

Michael BeckerBy Michael Becker•Aug 13, 2024

Here are the details about the latest PRTG release!

Paessler PRTG 23.2.83 is now available in the stable release channel!

Read the complete blog post here
Here are the details about the latest PRTG release!
Improved

Improved

Device iconSecurity

PRTG now validates the value of a device icon to avoid the risk of modifying it to possibly enter arbitrary content into the style tags when loading the Cascading Style Sheets (CSS) for the relevant page. (CVE-2022-35739)

For more information please see our Knowledge Base article: https://kb.paessler.com/en/topic/91149.

Web serverSecurity

We hardened PRTG against a possible Cross-Site Scripting (XSS) attack where a malicious actor could trick a victim into running injected javascript code over a manipulated link.

Notification DeliveryServer

With PRTG version 23.2.83 we now support TLS 1.3 in the Notification Delivery settings for the Delivery Mechanism Use one SMTP relay server (recommended in LANs/NATs). If you select this option, TLS 1.3 will additionally be displayed for the SSL/TLS Method radio group.

ReportsServer

We updated our reporting engine to the Chromium version 89. This update will improve the rendering of PDF reports that did not work in certain cases before. Chromium will create temporary files under %TEMP%/prtg_reporter that will be removed when the PDF report creation is finished.

Update to OpenSSL 1.1.1tServer

To ensure secure communication furthermore we updated to the OpenSSL version 1.1.1t. We now support TLS 1.3 in the connection security settings for High, Default and Weakened security connection in the Probe Connection settings and PRTG Web Server settings.

Important: Please note concerning your running HTTP sensors that we do not support any cryptographically broken ciphers for outgoing HTTP connections anymore with this update to OpenSSL 1.1.1t due to security reasons. This concerns the encryption methods MD5, DES, RC4. If you run any HTTP sensors for devices that do not offer any ciphers supported by OpenSSL 1.1.1t anymore, the sensors may run into an error with the message ssl3_read_bytes:sslv3 alert handshake failure.

For further information about the high security standards of PRTG please see our Knowledge Base article: https://kb.paessler.com/en/topic/61108.

HPE 3PAR Drive EnclosureSensors

We improved our HPE 3PAR Drive Enclosure sensors that in certain cases returned an error with the message An error occured. For more information, check the \Logs\sensors subfolder of the PRTG data directory on the probe system. If you have not enabled debug options, activate Store result under Debug Options in the settings of the sensor, rescan, and check the \Logs\sensors subfolder of the PRTG data directory on the probe system. showcage: invalid option -d. The issue occurred because the sensor uses the option showcage -d in the API what could not be processed by the Primera system, which instead uses the option showcage -all.

Microsoft Azure Subscription CostSensors

We updated our Microsoft Azure Subscription Cost sensors so that they now support the new Azure billing model from Microsoft. Before, the sensor returned an error in the result of sensor log with the message No billing periods found. Cannot continue since there are no individual billing periods anymore in the new Azure billing model and it uses invoices for calendar months instead.

Sensor security TLS connectionSensors

With the update of OpenSSL we also improved certain sensor types that now support TLS 1.3 connection security:

  • SSL Security Check sensor now has a new channel for TLS 1.3 TLS 1.3 (Perfect) that the sensor will check if it is supported by the target device and either display Accepted or Denied. In case of Denied, the sensor will report an error in the channel Security Rating.
  • HTTP Push Data sensor, HTTP Push Data Advanced sensor, HTTP Push Count sensor, HTTP IoT Push Data Advanced sensor now have a third option for TLS Settings for HTTPS high security (TLS 1.2 to 1.3 and strong ciphers). Default setting for added sensors will be HTTP Unsecure. If you use sensors running on HTTPs and update to this PRTG version, the sensors will use HTTPS low security (TLS 1.0 to 1.3 and weak ciphers) to stay compatible.

    Please note that all HTTP Push sensors always support TLS 1.3 even in low security setting. If you use HTTPS high security setting, TLS 1.0 and TLS 1.1 will be disabled and the sensors use the high security ciphers instead.
Sensor security digital signatureSensors

We improved several sensor types by signing them digitally with Secure Hash Algorithms sha256. In the previous PRTG version, these sensor types failed in certain cases when an AV scanner detected the unsigned .exe files as insecure. Sensor types improved, for example, are as follows: FTP Server File Count sensor, Windows MSMQ Queue Length sensor, Ping Jitter sensor, Windows Print Queue, Traceroute Hop Count sensor, HTTP XML/REST Value sensor.

All parts of PRTGVarious

Various other minor fixes and improvements.

Changed

Changed

Python Script AdvancedSensors

With PRTG version 23.2.83 we deliver a new Python distribution. Python distribution 3.9.13 includes security patches and several other improvements.

Please make sure your custom Python scripts are compatible with Python version 3.9.13. You only need to consider the change if you are using the Python Script Advanced Sensor.

Fixed

Fixed

Microsoft 365 Mailbox sensorSensors

We fixed an issue for the Microsoft 365 Mailbox sensor that could not match emails when you used special (non-ASCII) characters in the filter options Filter by 'subject' with Contains all or Contains any, for example words with accents like "é". The issue was located in the library used by the sensor where URL encoding did not work properly.

NotificationsServer

We fixed an issue where subjects in email notifications could not be displayed correctly in certain cases in previous PRTG version 23.1.82.2175 and 23.1.82.2074. The issue occurred in cases when you used diacritics or umlauts in the subjects of email notifications.

PRTG Core serverServer

We fixed an issue for the PRTG core server that caused high CPU usage in certain cases. The reason for this were connection threads in the background that were not terminated.

ReportsServer

You can now generate PDF reports again when you are logged in via single-sign on. We first introduced this feature for single-sign on with PRTG version 22.2.77.2204, yet it did not work anymore in the previous PRTG version. The PDF report only displayed the text Unauthorized instead of the report data.

Note

Note

PRTG application server portsPRTG API v2

The new UI and PRTG API v2 will now be served under port 1616 (HTTPS) or 1615 (HTTP). We exchanged the old configured ports HTTPS 8443 and HTTP 8080 because we experienced issues in certain cases that the PRTG application server could not start. Please ensure that these ports are not blocked by your firewall and be sure to update any bookmarks and hardcoded URLs. The Open new UI button in the classic UI will be updated automatically.

Discontinued NetApp Sensors with upcoming PRTG versionsSensors

With PRTG version 23.2.83 you will receive a to do ticket for your NetApp sensors that you still can add but they will no longer work when you update to ONTAP 9.13.1. NetApp ONTAPI will no longer be available by the end of July and NetApp delivers a new RESTful API (ONTAP REST API) for ONTAP based storage systems. With PRTG version 22.3.79.2108 we introduced new NetApp v2 (BETA) sensors that support ONTAP 9.6 and higher.

Please also see our Knowledge Base article for more information: https://kb.paessler.com/en/topic/90198

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Preview 23.1.83.1742

  • sha256_exe 64B149F521E642F129F12746CE341FC1F27C295492AB04AF3EB17531476D301D
  • sha256_zip 7F6422082081865010111B0FDF7C3C0CC8D10738D152565F3552054AD15F614F


Stable 23.2.83.1760

  • sha256_exe 1BC9CF151400EF422EAAE687CD6CF5E30E598D38848EEB55D409380635FAAFE4
  • sha256_zip CB2A73150272D74195DFD1EBF8F92BC202296833A6FE16DD11C30994AC1264CF
Docker Container StatusKnown Issues

Your Docker Container Status sensors may run into an error with the message bad certificate when you update to this PRTG version 23.2.83. We are currently analyzing the issue. 

Solved with PRTG 23.2.84.1566

Cache recalculationUpdate Notes

The update to this PRTG version will in most cases immediately cause a cache recalculation upon starting the PRTG server. While PRTG is usable during the cache recalculation, it will considerably consume more hardware resources like CPU and memory. Depending on your monitoring configuration, you may encounter negative effects on the performance of PRTG during this process. We recommend that you reserve extra time for the PRTG update.

SecurityITOps Board

We updated the ITOps to version 3.7.2 to fix an improper access control in the API which could have led to unwanted data leakage (CVE-2023-29488). 

Lab

Lab

NetApp SnapMirror v2Sensors

You will now receive the NetApp SnapMirror v2 sensor as a result when you add a sensor to a device on the Add sensor page. The sensor did not appear before when you searched for NetApp sensors and the radio button for Storage and File server was active.

REST Custom v2Sensors
  • The REST Custom v2 sensors now support the count function in arrays to get the number of elements that are included in an array.
  • We implemented a new value type String (status) which displays three text input fields when you select it for channel strings mapped to the Up, Warning and Down status. The text field input is optional. The channel is assigned to a static lookup file mapping the values for up, warning and down to the according status. The values are mapped to an integer before accordingly.
  • Your REST Custom v2 sensors now display the primary channel correctly on the sensor overview page when they are deployed via device template. In the previous PRTG versions, you had to set the primary channel manually afterwards of the device template auto-discovery.
  • You can now perform basic calculations on the result of REST queries with the REST Custom v2 sensors without using an extra custom script.
RedfishSensors

You will now receive results for Redfish sensors when you add a sensor from a device and search for the term Fujitsu on the Add sensor page /addsensor.htm. The sensors listed are Redfish Power Supply sensor (NEW), Redfish System Health sensor (NEW) and Redfish Virtual Disk sensor (BETA).

PRTG Probe adapterMulti-Platform Probe

With this PRTG version we deliver the DLL file for the PRTG probe adapter by default with the PRTG installer, to make the setup and the use of the Multi-Platform Probe easier. For more information about the Multi-Platform Probe please see our Knowledge Base article: https://kb.paessler.com/en/topic/90140

ControlsNew UI
  • You can now open the channel graphs page via the context menu button Show Channel Graph. The channel details and channel graph dialogues show error information in case of an error when data cannot be found or loaded.
  • You will now get a dialogue pop-up when you click on the Discard button for changing settings. The dialogue offers the options to Cancel or Confirm discarding your changes. You will get a similar dialogue message when you try to navigate to a different page or when you close the page. The dialogues only appear when you changed settings that you did not save.
Device SettingsNew UI
  • We improved the Basic Device Settings by displaying the Monitoring Status and the IP Version options as radio group. This change applies only if there are less than five selections per option.
  • You will now see the action bar buttons Discard and Save Settings when you are on the Basic Device Settings page. The action buttons were only visible after you made changes before. After the change, a text appears how many changes you have made, like 1 Change.
Web InterfaceNew UI
  • Channel details of a sensor are now displayed when you log in to the new UI again after a logout or timeout.
  • Data cache is now cleared when you log out from PRTG in the new UI.
  • We fixed an issue for lookups that in some cases displayed an error when you used custom lookup definitions with an unknown type.
  • We fixed an issue where the scrolled down position was saved on the sensor overview page. If you now scroll down on a sensor overview page and select another sensor overview page it will be displayed on the top again.
  • You now can use the new UI only with a valid license. In case you use an inactive license you will be redirected to https:///activation.htm when you log in to the new UI.
APIPRTG API v2

We improved the order of the settings of objects for the experimental section experimental/devices/ID/settings with the most used and most important settings at the top.

LicensesPRTG API v2

You can now run the PRTG application server and activate the new UI with a PRTG Enterprise license. This did not work before in the previous PRTG version when you used a PRTG Enterprise license. The error message returned was The functionality of your PRTG installation is currently limited. License is inactive.

PRTG application serverPRTG API v2
  • We fixed an issue for the information text file about open source libraries used in PRTG. You can find the prtgappserver_license_report.txt file in the PRTG installation path. The file contains information about library name, version, notice and license text.
  • We fixed an issue where in some cases the application server ran on 32-bit when the core server was operating in 64-bit mode. The application server now uses the same version that the core server runs.
  • We improved the startup check of the PRTG application server that in some cases did not come up when it did not receive certain sensor IDs from the PRTG core server.

PRTG Preview Version 23.1.82.2026

Release date: January 25, 2023

Blog article

Michael BeckerBy Michael Becker•Aug 13, 2024

All about the new PRTG release version 23.1.82

The latest release of Paessler PRTG is now available in the stable release channel! This version comes with the experimental Script v2 sensor, OPC UA sensors that now support unsecure connections to an OPC UA server, security improvements for certain sensor types and an update for German and Spanish language files.

Read the complete blog post here
All about the new PRTG release version 23.1.82
Improved

Improved

OPC UA sensorsSensors

The OPC UA Certificate, OPC UA Custom and OPC UA Server Status sensor types now support insecure connections to your OPC UA server with username and password authentication. Note that if you use this configuration, your data including passwords will be transmitted unencrypted.

Thank you for your feedback that the ability to monitor devices with such configurations is needed in several use cases.

SensorsSecurity

Additionally to the Exchange PowerShell, Citrix and EXE sensors in Paessler PRTG version 22.3.79, we also improved the method of password transmission for the following sensor types:

  • Active Directory Replication Errors sensor
  • FTP Server File Count sensor
  • HTTP XML/REST Value sensor
  • IP on DNS Blacklist sensor
  • Ping Jitter sensor
  • Traceroute Hop Count sensor
  • Windows Print Queue sensor
  • Windows MSMQ Queue Length sensor
  • WSUS Statistics sensor


Previously, passwords were sent in clear text. Now they are encrypted, so they are no longer visible in the Windows Event Log or Task Manager.

VulnerabilitySecurity

We fixed a vulnerability that affected certain exe sensors. We thank the reporter who brought this vulnerability to our attention.

UpdatesSecurity

PRTG now uses HTTPS by default when downloading new software versions for the PRTG auto-update.

All parts of PRTGVarious

Various other minor fixes and improvements.

LanguagesVarious

We updated the German and Spanish language files.

Fixed

Fixed

SMTP&POP3 Round TripSensors

We fixed an issue with the SMTP&POP3 Round Trip sensor that did not report an error if no email was found in the relevant mailbox. The issue was caused by the sensor matching any email on the mail server.

SSL CertificateSensors

The SSL Certificate sensor works with a Virtual Host (SNI Name) again even if the SNI name does not contain a dot (.). In previous versions, the sensor showed a down status with the error message Connection reset by peer (socket error # 10054) if the SNI name had no dot. For example, the sensor still worked as expected with example.com but not with example as SNI name. Additionally, the SSL Certificate sensor now supports domains that contain an umlaut (like ü or ä) in the name.

Access rightsServer

Read-only users can change their password by themselves again if the PRTG System Administrator enables the option Allow user to change the account password in their user account settings.

PRTG Core ServerServer

We fixed an issue where in some cases certain licensee names caused the service for the PRTG core server to stop. The issue occurred during the license activation process.

Remote probesServer

The automatic update of a large number of remote probes to the latest PRTG version properly works again. In previous versions, remote probes required a manual update after 20 automatically updated remote probes.

TutorialsWeb GUI

You can now watch again the PRTG Tutorial: Creating Maps on the PRTG Welcome page. The link did not work anymore in the previous versions.

Note

Note

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Preview 23.1.82.2026

  • sha256_exe B5A8A06EF616F023E6EFCE31031036ACDB08EC128BAEF5143DD16F36E18DFEE2
  • sha256_zip F04C82387B012049633C48CDAAA369A7368D58C3B6CA3B36B654CF79F5F41683


Stable 23.1.82.2074

  • sha256_exe 0ACD4ABDE0AA527E417E22148ABE1818639064B06D9D8E48F4281B945AA69710
  • sha256_zip F2F262AB9F98919C290B8159BDE1CAF8D1D2377562CC8A692B3E4345E11D0CAF
StabilityPRTG API v2

The new UI is now stable enough to be activated on production systems. Previously, we recommended that you activate the new UI only in test environments. When you activate it, you can use it side-by-side with the classic UI.

Please note that the new UI and PRTG API v2 are still in an ongoing development process and that several features are missing.

For further information about features, requirements and known issues for PRTG API v2 and the new UI please see our Knowledge Base article: I want to use the new UI and API v2. What do I need to know?

Lab

Lab

HTTP v2Sensors
  • We fixed an issue in the multi-edit menu that caused an error in the required fields validation for the post body. As a result, the Post Body field is no longer marked as a required field when you select POST as Request Method.
  • We fixed an issue with the timeout setting in the HTTP v2 sensor. Previously, the sensor did not report an error even if the requested HTTP page did not respond within a certain limit of time.
Ping v2Sensors

The Response Time channel is now set as the primary channel for the Ping v2 sensor if you created the sensor with Inverted Error Status disabled and multiple pings. The sensor still shows the Status channel as the primary channel if you enabled the Inverted Error Status feature when creating the sensor.

Script v2Sensors

You can try out the experimental Script v2 sensor that also works on the Multi-Platform Probe. The sensor executes a Python script that returns data in JSON format and shows the exit code. This way you can create your own custom script sensors that may not be available in PRTG by default.

For available example scripts and how to use them, please see the Knowledge Base article: https://kb.paessler.com/en/topic/91349

ControlsNew UI
  • You can now change the basic settings of a device in the Basic Device Settings section. The basic settings of a device include Status, IPv4 Address/DNS Name, IP Version, Device Name and Priority.
  • You can now resume acknowledged alarms for sensors using the Clear Acknowledged Alarm button via the context menu and bulk edit change.
Mobile ViewNew UI

The mobile view now shows channels with unknown lookup states.

ChannelsNew UI

We fixed an issue in the sensor graphs section to avoid the risk of possible cross-site scripting (XSS) attacks.

SecurityNew UI

We fixed an issue for sensor channel values that were sometimes displayed in too large numbers.

Web InterfaceNew UI
  • You can now share the graphs page with a URL link.
  • You can now see the specific scanning times of a sensor if you have defined them as described in https://https://kb.paessler.com/en/topic/3723. In this case, the scanning interval is named Irregular and shows the scanning times in a tooltip.
  • We implemented live graphs for channels that show a down or warning status on the sensor and device overview cards.
  • We fixed an issue on the sensor graphs page that caused a reset after an automatic refresh if you interacted with the graphs, such as zooming in.
  • You can open graphs in a dedicated, larger view.
  • We have updated the content of the PRTG Welcome page to reflect the new features available.
DevicesPRTG API v2
  • You can now delete a device with a DELETE request in the experimental section /experimental/devices/{id}. If the request was successful, you will get a 204 response code in return.

    Note: You can only delete devices, not probes or groups, for example.
  • You can now edit the settings of a device by sending a PATCH request to /experimental/devices/ {id}. Please note that this feature is still in experimental status and does not contain all functionalities yet.
SensorsPRTG API v2

We fixed an issue in the experimental section for the settings endpoints /experimental/sensors/ID/settings and /experimental/devices/ID/settings. The settings were returned empty after you created a device or sensor.

ChannelsPRTG API v2

We renamed the scale field in the payload of channels to scaling and improved the description.

Web InterfacePRTG API v2

We fixed an issue for sensor channel values that were sometimes displayed in too large numbers.

1
...
121314

Products

  • Paessler PRTG
    Paessler PRTGMonitor your whole IT infrastructure
    • PRTG Network Monitor
    • PRTG Enterprise Monitor
    • PRTG Hosted Monitor
    • PRTG extensions
      Extensions for Paessler PRTGExtend your monitoring to a new level
  • Icon Features
    FeaturesExplore all monitoring features

Monitoring with PRTG

  • Network monitoring
  • Bandwidth monitoring
  • SNMP monitoring
  • Network mapping
  • Wi-Fi monitoring
  • Server monitoring
  • Network traffic analyzer
  • NetFlow monitoring
  • Syslog server

Useful Links

  • PRTG Manual
  • Knowledge Base
  • Customer Success Stories
  • About Paessler
  • Subscribe to newsletter
  • PRTG Support
  • PRTG Consulting
  • PRTG Feedback & Roadmap

Contact

Paessler GmbH
Thurn-und-Taxis-Str. 14, 
90411 Nuremberg 
Germany

[email protected]

+49 911 93775-0

  • Contact us
©2026 Paessler GmbHTerms & ConditionsPrivacy PolicyImprintTrust CenterDownload & InstallSitemap
Virtualization Virtualization Virtualization