PRTG Manual: SSH Script Sensor
The SSH Script sensor connects to a Linux/Unix system via Secure Shell (SSH) and executes a script file that is located on the target system. This option is available as part of the PRTG API.
For a detailed list and descriptions of the channels that this sensor can show, see section Channel List.
- Dutch: SSH Script
- French: Script (SSH)
- German: SSH-Skript
- Japanese: SSH スクリプト
- Portuguese: Script (SSH)
- Russian: Скрипт SSH
- Simplified Chinese: SSH 脚本
- Spanish: Script (SSH)
- This sensor has a very high performance impact. We recommend that you use no more than 50 of this sensor on each probe.
- For security reasons, this sensor requires that you store your script file in the /var/prtg/scripts directory on the target system. Make sure that the script has executable rights. If the script is not available or was deleted from the directory, you get the error message Script not found (237).
- This sensor requires credentials for Linux/Solaris/macOS (SSH/WBEM) systems in the settings of the parent device.
- This sensor does not support all Linux/Unix and macOS distributions.
- This sensor only supports IPv4.
- For more information about the return value format, see the PRTG Manual Custom Sensors.
- Knowledge Base: Which encryption algorithms do PRTG SSH sensors support?
- Knowledge Base: SSH and SFTP sensors in Unknown status
Setting |
Description |
---|---|
Channel Name |
Enter a name for the channel. Enter a string. This is for display purposes only.
|
Setting |
Description |
---|---|
Sensor Name |
Enter a name to identify the sensor. By default, PRTG shows this name in the device tree, as well as in alarms, logs, notifications, reports, maps, libraries, and tickets.
|
Parent Tags |
The tags that the sensor inherits from its parent device, parent group, and parent probe.
|
Tags |
Enter one or more tags. Confirm each tag with the Spacebar key, a comma, or the Enter key. You can use tags to group objects and use tag-filtered views later on. Tags are not case-sensitive. Tags are automatically inherited.
The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:
|
Priority |
Select a priority for the sensor. This setting determines the position of the sensor in lists. The highest priority is at the top of a list. Choose from the lowest priority ( |
Credentials for Script Sensors
Click to interrupt the inheritance.
Setting |
Description |
---|---|
Placeholder 1 Description |
Enter a description for Placeholder 1, for example information about the purpose or content of the placeholder. |
Placeholder 1 |
Enter a value for the placeholder. PRTG inserts the value for the script execution if you add %scriptplaceholder1 in the argument list. PRTG does not display the value in the sensor log or the sensor's settings. |
Placeholder 2 Description |
Enter a description for Placeholder 2, for example information about the purpose or content of the placeholder. |
Placeholder 2 |
Enter a value for the placeholder. PRTG inserts the value for the script execution if you add %scriptplaceholder2 in the argument list. PRTG does not display the value in the sensor log or the sensor's settings. |
Placeholder 3 Description |
Enter a description for Placeholder 3, for example information about the purpose or content of the placeholder. |
Placeholder 3 |
Enter a value for the placeholder. PRTG inserts the value for the script execution if you add %scriptplaceholder3 in the argument list. PRTG does not display the value in the sensor log or the sensor's settings. |
Placeholder 4 Description |
Enter a description for Placeholder 4, for example information about the purpose or content of the placeholder. |
Placeholder 4 |
Enter a value for the placeholder. PRTG inserts the value for the script execution if you add %scriptplaceholder4 in the argument list. PRTG does not display the value in the sensor log or the sensor's settings. |
Placeholder 5 Description |
Enter a description for Placeholder 5, for example information about the purpose or content of the placeholder. |
Placeholder 5 |
Enter a value for the placeholder. PRTG inserts the value for the script execution if you add %scriptplaceholder5 in the argument list. PRTG does not display the value in the sensor log or the sensor's settings. |
Setting |
Description |
---|---|
Script |
Select a script file from the dropdown list. It shows all script files that are available in the /var/prtg/scripts directory on the target Linux/Unix system. For a script file to appear in this list, store the target file in this directory.
|
Character Encoding |
Define the character encoding that you use in your script to correctly display the sensor message:
|
Parameters |
If your script file catches command-line parameters, define them here. You can also use placeholders. Enter a string or leave the field empty.
|
Mutex Name |
Define a mutual exclusion (mutex) name for the process. Enter a string or leave the field empty.
|
Unit String |
Define a unit for the channel value. Enter a string. This is for display purposes only and is the default unit for a new channel. You can change the unit after sensor creation in the sensor's channel settings. |
Value Type |
Define the type of the values that your executable or script file returns:
|
If Value Changes |
Define what the sensor does when its value changes:
|
Setting |
Description |
---|---|
Connection Timeout (Sec.) |
Define a timeout in seconds for the connection. This is the time that the sensor waits to establish a connection to the host. Keep this value as low as possible. Enter an integer.
|
Shell Timeout (Sec.) |
Define a timeout in seconds for the shell response. This is the time in seconds the sensor waits for the shell to return a response after it has sent its specific command (for example, cat /proc/loadavg). The maximum value is 300 seconds (5 minutes). Enter an integer.
|
SSH Port |
Define which port this sensor uses for the SSH connection:
|
Use Port Number |
This setting is only visible if you select Enter custom port number above. Enter the port number (between 1 and 65535) that this sensor uses for the SSH connection. Enter an integer. |
SSH Engine |
Select the SSH engine that you want to use to access data with this SSH sensor. Choose between:
|
Result Handling |
Define what PRTG does with the sensor result:
|
Setting |
Description |
---|---|
Primary Channel |
Select a channel from the list to define it as the primary channel. In the device tree, the last value of the primary channel is always displayed below the sensor's name. The available options depend on what channels are available for this sensor.
|
Graph Type |
Define how different channels are shown for this sensor:
|
Stack Unit |
This setting is only visible if you enable Stack channels on top of each other as Graph Type. Select a unit from the list. All channels with this unit are stacked on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so. |
By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click under the corresponding setting name to disable the inheritance and to display its options.
For more information, see section Inheritance of Settings.
For more information, see section Root Group Settings, section Scanning Interval.
Schedules, Dependencies, and Maintenance Window
You cannot interrupt the inheritance for schedules, dependencies, and maintenance windows. The corresponding settings from the parent objects are always active. However, you can define additional schedules, dependencies, and maintenance windows. They are active at the same time as the parent objects' settings.
For more information, see section Root Group Settings, section Schedules, Dependencies, and Maintenance Window.
For more information, see section Root Group Settings, section Access Rights.
Which channel units are available depends on the sensor type and the available parameters. If no configurable channels are available, this field shows No configurable channels.
For more information, see section Root Group Settings, section Channel Unit Configuration.
Escape Special Characters and Whitespaces in Parameters
You need to escape special characters in parameters that you pass to an executable or script and surround them with quotation marks to make sure that the characters are correctly interpreted. PowerShell scripts in particular require adequate escaping so that the parameters are passed in a valid PowerShell syntax. PRTG automatically does most of the escaping for you.
Follow these rules to escape special characters and whitespaces in the parameters fields:
- Use double (") or single (') quotation marks for parameters that contain whitespaces.
-name "Mr John Q Public"
-name 'Mr John Q Public'
- Use double quotation marks (") for parameters that already contain single quotation marks (').
-name "Mr 'John Q' Public"
- Use single quotation marks (') for parameters that already contain double quotation marks (").
-name 'Mr "John Q" Public'
- Use a backslash (\) to escape and pass a literal double quotation mark.
-name pub\"lic
- Use double quotation marks (") for parameters that contain double ('') and single (') quotation marks and escape double quotation marks (").
-name "pu'b\"lic"
In SSH scripts, you can use alphanumeric characters and the special characters ".", "_", "-", "=", and "/" outside of quoted strings.
We recommend that you do not pass passwords in parameters. Use placeholders instead. See section Custom Sensors for details.
Which channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.
Channel |
Description |
---|---|
Downtime |
In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status |
Execution Time |
The execution time
|
[Value] |
The value that the script file returns in one channel
|
KNOWLEDGE BASE
Which encryption algorithms do PRTG SSH sensors support?
SSH and SFTP sensors in Unknown status
Is there a shell script example for the SSH Script sensor?
What security features does PRTG include?
What is the Mutex Name in the EXE/Script sensor settings?
How can I test if parameters are correctly transmitted to my script when using an EXE/Script sensor?
How can I show special characters with EXE/Script sensors?
Why do I have to store SQL sensor queries and custom scripts in files on the probe computer?