Data flow | Multi-Platform Probe for PRTG

Multi-Platform Probe for PRTG

Data flow

The multi-platform probe begins to send monitoring data to PRTG as soon as you configure sensors. Like the classic remote probe, the multi-platform probe monitors its remote probe system autonomously and sends the monitoring results to the PRTG core server with each scan.

Interrupted data flow

If the connection between the multi-platform probe and the PRTG core server fails for any reason, the remote probe continues to monitor as long as it is still active. It buffers the monitoring results until the connection is reestablished and normal data flow  resumes.

Possible causes of communication loss:

▪Unstable network connection

▪Loss of power or other environmental factors

▪Component failure

▪Network configuration issues

Data buffering scenarios

The multi-platform probe is down.

If a multi-platform probe is down, it cannot generate monitoring data.

Check the status of the multi-platform probe:

systemctl status prtg.mpprobe.service

If the status is not active (running), you might need to restart the remote probe. Check the multi-platform probe logs for more information on why the remote probe is down.

The PRTG core server is down or there is no connection between the PRTG core server and the multi-platform probe.

If the PRTG core server is down or the connection fails, the multi-platform probe buffers monitoring data until it can reconnect. Once the buffer reaches its limit, the remote probe stops monitoring until there is space available again.

The multi-platform probe retries the connection every 30 seconds. As soon as it reconnects, it sends the buffered monitoring data and resumes normal operation.

i_round_redDo not restart the multi-platform probe while the PRTG core server is down or disconnected if you want to preserve monitoring data. The multi-platform probe holds the buffer in memory, so the buffer is lost every time you restart the multi-platform probe.

Notes

▪The time it takes for the buffer to reach its limit is dependent on the number of sensors, scanning intervals, the number of channels, and other factors. A multi-platform probe with many sensors and short scanning intervals fills the buffer much faster than a multi-platform probe with few sensors and long scanning intervals.

▪The buffer preserves the oldest monitoring data and does not overwrite it with new monitoring data.

▪If you want to change the default limits of the data buffer, contact the Paessler support team to find a configuration that works best with your system.

▪If a connection fails or a component goes down, you might experience some minor losses in monitoring data. This can happen, for example, when a data package was already on its way to the PRTG core server when the connection failed.