Common Settings for all SNMP Sensor Types

The following settings are available for all SNMP based sensors:

·      Community String—the SNMP public access string (usually "public"), used for SNMP V1 and V2c

·      SNMP Port—the UDP port used for SNMP by your device (usually "161")

·      Connection Info—the status info which is read directly from the device (read only!).

·      Lower valid limit—enter the minimum valid value (if the measured value is below this limit the sensor will enter an error state). Enter –1 to disable the check.

·      Upper valid limit—enter the maximum valid value (if the measured value is above this limit the sensor will enter an error state). Enter –1 to disable the check.

·      Low—enter the lower warning value (if the measured value is below this limit the sensor will enter a warning state). Enter –1 to disable the check.

·      High—enter the high warning value (if the measured value is above this limit the sensor will enter a warning state). Enter –1 to disable the check.

Navigation: Contents   Index   Previous   Next